DataLad dataset containing BIDS-converted MRI data used in Wittkuhn & Schuck, 2020, Nature Communications. For details, see:

Lennart Wittkuhn f89333c27a add requirements.txt file listing required packages há 4 anos atrás
.datalad a4652dfd2b Configure metadata type(s) há 4 anos atrás
.heudiconv a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
code 86f7d1150b Merge remote-tracking branch 'origin/master' há 4 anos atrás
input b2e0c94005 add empty input directory using .gitkeep há 4 anos atrás
logs 4223e4692d add empty logs directory há 4 anos atrás
sub-01 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-02 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-03 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-04 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-05 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-06 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-07 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-08 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-09 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-10 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-11 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-12 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-13 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-14 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-15 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-16 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-17 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-18 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-19 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-20 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-21 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-22 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-23 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-24 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-25 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-26 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-27 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-28 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-29 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-30 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-31 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-32 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-33 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-34 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-35 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-36 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-37 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-38 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-39 a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
sub-40 2f8992b781 re-run heudiconv and defacing for sub-40 after increasing memory demand in heudiconv code há 4 anos atrás
tools @ 4dac41c4fc 1455f7af90 add LICENSE and DOI há 4 anos atrás
.gitattributes f89333c27a add requirements.txt file listing required packages há 4 anos atrás
.gitignore d10ec6f900 add html rendering of docs page to .gitignore há 4 anos atrás
.gitmodules 29783c8c87 [DATALAD] Recorded changes há 4 anos atrás
CHANGES a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
LICENSE 1455f7af90 add LICENSE and DOI há 4 anos atrás
README a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
datacite.yml 1455f7af90 add LICENSE and DOI há 4 anos atrás
dataset_description.json a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
highspeed-bids.Rproj ea54b9049a add R project to git há 4 anos atrás
participants.json a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
participants.tsv a2b905b439 add defaced BIDS-converted MRI data after running heudiconv and defacing há 4 anos atrás
requirements.txt f89333c27a add requirements.txt file listing required packages há 4 anos atrás

README

TODO: Provide description for the dataset -- basic details about the study, possibly pointing to pre-registration (if public or embargoed)
datacite.yml
Title Faster than thought: Detecting sub-second activation sequences with sequential fMRI pattern analysis
Authors Wittkuhn,Lennart;Max Planck Institute for Human Development, Max Planck UCL Centre for Computational Psychiatry and Ageing Research, Berlin, Germany;ORCID:0000-0001-2345-6789
Schuck,Nicolas W.;Max Planck Institute for Human Development, Max Planck UCL Centre for Computational Psychiatry and Ageing Research, Berlin, Germany;ResearcherID:X-1234-5678
Description Neural computations are often anatomically localized and executed on sub-second time scales. Understanding the brain therefore requires methods that offer sufficient spatial and temporal resolution. This poses a particular challenge for the study of the human brain because non-invasive methods have either high temporal or spatial resolution, but not both. Here, we introduce a novel multivariate analysis method for conventional blood-oxygen-level dependent functional magnetic resonance imaging (BOLD fMRI) that allows to study sequentially activated neural patterns separated by less than 100 ms with anatomical precision. Human participants underwent fMRI and were presented with sequences of visual stimuli separated by 32 to 2048 ms. Probabilistic pattern classifiers were trained on fMRI data to detect the presence of image-specific activation patterns in early visual and ventral temporal cortex. The classifiers were then applied to data recorded during sequences of the same images presented at increasing speeds. Our results show that probabilistic classifier time courses allowed to detect neural representations and their order, even when images were separated by only 32 ms. Moreover, the frequency spectrum of the statistical sequentiality metric distinguished between sequence speeds on sub-second versus supra-second time scales. These results survived when data with high levels of noise and rare sequence events at unknown times were analyzed. Our method promises to lay the groundwork for novel investigations of fast neural computations in the human brain, such as hippocampal replay.
License Creative Commons Attribution-NonCommercial-ShareAlike 4.0 (https://creativecommons.org/licenses/by-nc-sa/4.0/)
References Wittkuhn, L. and Schuck, N. W. (2020). Faster than thought: Detecting sub-second activation sequences with sequential fMRI pattern analysis. bioRxiv. doi:10.1101/2020.02.15.950667 [doi:10.1101/2020.02.15.950667] (IsSupplementTo)
Funding Max Planck Society (M.TN.A.BILD0004)
Max Planck Institute for Human Development
Keywords Neuroscience
functional magnetic resonance imaging
hippocampal replay
Resource Type Dataset