Scheduled service maintenance on November 22


On Friday, November 22, 2024, between 06:00 CET and 18:00 CET, GIN services will undergo planned maintenance. Extended service interruptions should be expected. We will try to keep downtimes to a minimum, but recommend that users avoid critical tasks, large data uploads, or DOI requests during this time.

We apologize for any inconvenience.

README.md 2.3 KB

EEG_DPAOE_attention

Full EEG and DPAOE data for Dragicevic et al., PLoS One, 2018. DOI: 10.1371/journal.pone.0208939.

Data provided here is in ELAN format. You can download ELAN for free (http://elan.lyon.inserm.fr). If you have any question do not hesitate to ask Dr. Constantino Dragicevic at cdragicevic@gmail.com. If you have problems with your ip address for downloading ELAN, you may contact Dr. Aguera at pe.aguera@inserm.fr, who wrote the ELAN software.

The .eeg files contain filtered data (<30Hz) of every recorded channel. The order of the channels is given at the end of this document, but it is also included in the header files .ent, associated with each .eeg file. A separate .pos file including time events is included, though this information is also inside the .eeg files. Inside the .pos files all the relevant events of our experiment are coded with a number from 1 to 6. Any other event code is related with the concatenation of non continuous data (our experimental blocks) into the single .eeg file. Please note that the results shown in the paper relate to event codes 1 (onset of the visual task) and 4 (onset of the auditory task, which coincides with the visual behavioral response). This events passed our first rejection process regarding artifactual positive or negative peak in DPOAE amplitude. Regarding the .eeg files, it has a total of 38 channels, listed at the end of this document, with a sampling rate of 256 Hz. The first 2 channels are electro-ocular (EOG) data (bipolar vertical (VEOG) and horizontal (HEOG), respectively). Then are two versions of the virtual DPOAE channel (DP and HA). The first one is based on a Fourier approach, and then the Hilbert approach. Though results with both are similar, we preferred the Hilbert approach, and all results reported in the paper are based on the Hilbert based DPOAE amplitude channel. Next we have the Fz electrode of the EEG. Following Fz, two controls are included (CTRLF1 and CTRL2). One is the F1 tone amplitude, and the other is the amplitude of the frequency at the middle between the DPOAE frequency and F1. The remaining channels are all EEG, and have the standard 10-20 names. List of channels:

VEOG HEOG DP HA Fz CTRLF1 CTRL2 F3 Fc1 Cz Fc2 F4 P3 O1 Pz O2 P4 Tp9 Fp2 Cp2 C4 Po10 F8 Fc6 T8 P8 Ft10 Cp6 Fp1 Cp1 F7 Fc5 C3 Cp5 Ft9 T7 P7 Po9