123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519520521522523524525526527528529530531532533534535536537538539540541542543544545546547548549550551552553554555556557558559560561562563564565566567568569570571572573574575576577578579580581582583584585586587588589590591592593594595596597598599600601602603604605606607608609610611612613614615616617618619620621622623624625626627628629630631632633634635636637638639640641642643644645646647648649650651652653654655656657658659660661662663664665666667668669670671672673674675676677678679680681682683684685686687688689690691692693694695696697698699700701702703704705706707708709710711712713714715716717718719720721722723724725726727728729730731732733734735736737738739740741742743744745746747748749750751752753754755756757758759760761762763764765766767768769770771772773774775776777778779780781782783784785786787788789790791792793794795796797798799800801802803804805806807808809810811812813814815816817818819820821822823824825826827828829830831832833834835836837838839840841842843844845846847848849850851852853854855856 |
- <?xml version="1.0" encoding="UTF-8"?>
- <?xml-stylesheet type="text/xsl" href="odmlTerms.xsl"?>
- <?xml-stylesheet type="text/xsl" href="odml.xsl"?>
- <odML xmlns:gui="http://www.g-node.org/guiml" version="1">
- <version>1</version>
- <date>2015-07-16</date>
- <section>
- <type>new</type>
- <name>Experiment</name>
- <property>
- <name>start-time</name>
- <gui:required>true</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- 09.03.2011, 15:00:00
- <type>string</type>
- </value>
- </property>
- <property>
- <name>end-time</name>
- <gui:required>true</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- 09.03.2011, 15:40:00
- <type>string</type>
- </value>
- </property>
- <property>
- <name>research-group</name>
- <gui:required>true</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>2</gui:order>
- <value>
- EEG_Janak_Attention
- <type>string</type>
- </value>
- </property>
- <property>
- <name>scenario-title</name>
- <gui:required>true</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>3</gui:order>
- <value>
- Driver's attention and visual stimulation
- <type>string</type>
- </value>
- </property>
- <section>
- <type>new</type>
- <name>Experimenters</name>
- <property>
- <name>Experimenter #1</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- Ing. Pavel Mautner, Ph.D.
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Experimenter #2</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- Ing. Roman Mouček, Ph.D.
- <type>string</type>
- </value>
- </property>
- </section>
- </section>
- <section>
- <type>new</type>
- <name>Subject</name>
- <property>
- <name>Gender</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- male
- <type>string</type>
- </value>
- <value>
- female
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Age</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- 22
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Digitization</name>
- <property>
- <name>Sampling-rate</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- 1000 Hz
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Hardware</name>
- <section>
- <type>new</type>
- <name>EEG cap</name>
- <property>
- <name>Type</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- Medium, 54 - 58 cm (red)
- <type>string</type>
- </value>
- <value>
- Large, 58 - 62 cm (dark blue)
- <type>string</type>
- </value>
- <value>
- Small, 50 - 54 cm (yellow)
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- EEG cap captures the signal of neuronal activity in the brain from the head surface using electrode application technique.
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Inventory number</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>2</gui:order>
- <value>
- 17196
- <type>string</type>
- </value>
- <value>
- 21050
- <type>string</type>
- </value>
- <value>
- 16884
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Manufacturer</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>3</gui:order>
- <value>
- Electro-Cap International, Inc. Eaton, Ohio 45320 USA
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Electrode</name>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- An electrode is an electrical conductor used to make contact with a nonmetallic part of a circuit (e.g., the human scalp) and is used to measure electrical activity. http://purl.bioontology.org/NEMO/ontology/NEMO.owl#NEMO_0000501
- <type>string</type>
- </value>
- </property>
- <section>
- <type>new</type>
- <name>Eye Blink Detection Electrode</name>
- <property>
- <name>Title</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- E21-9S DISK ELECTRODE
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- A pure tin cup electrode with a 48" (122 cm) lead wire and a female socket. Device is used as a reference electrode.
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Owner</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>2</gui:order>
- <value>
- Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Type</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>3</gui:order>
- <value>
- Standard 9mm cup
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Manufacturer</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>4</gui:order>
- <value>
- Electro-Cap International, Inc. Eaton, Ohio 45320 USA
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Reference</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>5</gui:order>
- <value>
- http://www.electro-cap.com/index.cfm/supplies/
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Reference Electrode</name>
- <property>
- <name>Title</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- E21-9S DISK ELECTRODE
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- A pure tin cup electrode with a 48" (122 cm) lead wire and a female socket. Device is used as a reference electrode.
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Owner</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>2</gui:order>
- <value>
- Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Type</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>3</gui:order>
- <value>
- Standard 9mm cup
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Manufacturer</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>4</gui:order>
- <value>
- Electro-Cap International, Inc. Eaton, Ohio 45320 USA
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Reference</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>5</gui:order>
- <value>
- http://www.electro-cap.com/index.cfm/supplies/
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Ground Electrode</name>
- <property>
- <name>Title</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- E5-9S EAR ELECTRODE
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- A pair of pure tin cup electrodes with a 48" (122 cm) lead wire and a female socket. A spring-clip back, covered with plastic for patient comfort, is used to hold the electrode in place. Device is used as a ground electrode.
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Owner</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>2</gui:order>
- <value>
- Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Type</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>3</gui:order>
- <value>
- Standard 9mm cup
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Manufacturer</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>4</gui:order>
- <value>
- Electro-Cap International, Inc. Eaton, Ohio 45320 USA
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Reference</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>5</gui:order>
- <value>
- http://www.electro-cap.com/index.cfm/supplies/
- <type>string</type>
- </value>
- </property>
- </section>
- </section>
- <section>
- <type>new</type>
- <name>Car simulator</name>
- <property>
- <name>Stimulatory light</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- A light-emitting diode (LED) is a semiconductor light source.
- <type>string</type>
- </value>
- </property>
- <section>
- <type>new</type>
- <name>Bodywork</name>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- Bodywork is the body of a motor vehicle (automobile, bus or truck), a horse-drawn coach or carriage (whence the term originated), or, by extension, a railroad car or railway carriage. An obsolescent synonym is carrossery.
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Car model</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- Skoda Octavia - is a brand of the car bodywork used for our experimental car.
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Steering wheel</name>
- <property>
- <name>Type</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- G27 Racing Wheel Steering wheel
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- A game wheel that controls steering, as in the car simulator. Device is used for measuring driver´s experiments.
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Pedals</name>
- <property>
- <name>Type</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- G27 Racing Wheel pedals
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- G27 Racing Wheel pedals device has the steel gas, brake, and clutch pedals deliver precise throttle, braking, and shifting control for heightened realism.Device is used for measuring driver´s experiments.
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Shifter</name>
- <property>
- <name>Type</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- G27 Racing Wheel shifter
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- G27 Racing Wheel shifter is a six-speed shifter used for shift gears in driver´s experiments.
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Digital projector</name>
- <property>
- <name>Type</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- The Acer P5280
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- The Acer P5280 is a digital projector used for projection of stimulation protokol.
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Sound system</name>
- <property>
- <name>Type</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- Logitech X140
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- Total RMS power: 5 watts RMS (2.5 x 2) Total peak power: 10 watts Frequency response: 80Hz - 18kHz 7 cm high-excursion driver with 7.6 cm pressure driver Speaker dimensions 24.1 x 9.9 x 12.4 (H x W x D, cm)
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Camera system</name>
- <property>
- <name>Type</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- HD Pro Webcam C920
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- Full HD 1080p video calling (up to 1920 x 1080 pixels) with the latest version of Skype for Windows* 720p HD video calling (up to 1280 x 720 pixels) with supported clients Full HD video recording (up to 1920 x 1080 pixels) with a recommended system** Logitech Fluid Crystal™ Technology H.264 video compression* Carl Zeiss® lens with 20-step autofocus Built-in dual stereo mics with automatic noise reduction Automatic low-light correction Hi-Speed USB 2.0 certified (USB 3.0 ready) Tripod-ready universal clip fits laptops, LCD or CRT monitors
- <type>string</type>
- </value>
- </property>
- </section>
- </section>
- <section>
- <type>new</type>
- <name>Amplifier</name>
- <property>
- <name>Title</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- V-Amp 16
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Type</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- digital DC amplifier input 5V DC, 450mA
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>2</gui:order>
- <value>
- The V-Amp is used for recording EEG signal and the full range of evoked potentials. Amplifier has two auxiliary ports for measuring peripheral signals like GSR, blood flow, body temperature.
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Serial number</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>3</gui:order>
- <value>
- AMP 10021151 VA16
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Inventory number</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>4</gui:order>
- <value>
- 501421
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Owner</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>5</gui:order>
- <value>
- Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Number of channels</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>6</gui:order>
- <value>
- 18
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Manufacturer</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>7</gui:order>
- <value>
- Brain Products
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Reference</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>8</gui:order>
- <value>
- http://www.brainproducts.com/productdetails.php?id=15
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Stimulation computer</name>
- <property>
- <name>Type</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- HP station
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- Stimulation computer used processor Intel Xeon E5 1650 3,5 GHz. It has 16 GB RAM. Stimulation computer is used for playing stimulation protocol.
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Recording computer</name>
- <property>
- <name>Type</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- Notebook DELL LATITUDE
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- Recording computer used processor Intel Core i7 CPU 3,2GHz 3,19GHz. It has 12 GB RAM. Device is used for recording EEG/ERP from drivers or mice blindness expreriments.
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Auditory presentation computer</name>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- Auditory presentation computer used processor Intel Core i7 CPU 2,67GHz 2,67GHz. It has 12 GB RAM. Stimulation computer is used for playing stimulation protocol.
- <type>string</type>
- </value>
- </property>
- </section>
- </section>
- <section>
- <type>new</type>
- <name>Accessories</name>
- <section>
- <type>new</type>
- <name>Electro Gel</name>
- <property>
- <name>Title</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- ELECTRO-GEL NET:16
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- This electro-gel is an off white color, water-miscible conductive gel. Electro-gel is a mixture of the following components: Water, Sodium Chloride, Aragum, Glycerin, Pottasium Bitartrate, Methylparaben and Propylparaben. Electro gel is applied by inserting the gel into the EEG cap electrodes by using a syringe and blunted needle. Electro gel is used for setting low electrode impedance and limitations of electrode artifacts.
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Manufacturer</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>2</gui:order>
- <value>
- ELECTRO-Cap International, Inc. 1011 W. Lexington Road Eaton, Ohio 45320 U.S.A.
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Conductive Paste</name>
- <property>
- <name>Title</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- Ten 20 CONDUCTIVE EEG Paste
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- Ten20 is a conductive and adhesive paste specifically formulated for use with reusable (non-disposable) electrodes. Primarily used for EEG electrodes. (http://www.biopac.com/ten20-conductivegel)
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Manufacturer</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>2</gui:order>
- <value>
- Weaver and Company 565 Nucla Way Unit B Aurora, CO 80011 Toll Free 800-525-2130 Fax 303-367-5118
- <type>string</type>
- </value>
- </property>
- </section>
- <section>
- <type>new</type>
- <name>Degreasing Gel</name>
- <property>
- <name>Title</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- Nuprep
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- Nuprep gel is applied to electrode site on scalp with cotton swab. EEG electrode paste and reference or ground electrode is applied over Nuprep gel.
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Manufacturer</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>2</gui:order>
- <value>
- Weaver and Company 565 Nucla Way Unit B Aurora, CO 80011 Toll Free 800-525-2130 Fax 303-367-5118
- <type>string</type>
- </value>
- </property>
- </section>
- </section>
- <section>
- <type>new</type>
- <name>Software</name>
- <property>
- <name>Title</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>0</gui:order>
- <value>
- BrainVision Recorder 1.2
- <type>string</type>
- </value>
- </property>
- <property>
- <name>Description</name>
- <gui:required>false</gui:required>
- <gui:editable>true</gui:editable>
- <gui:order>1</gui:order>
- <value>
- EEG/ERP recording software
- <type>string</type>
- </value>
- </property>
- </section>
- </odML>
|