|
@@ -0,0 +1,856 @@
|
|
|
+<?xml version="1.0" encoding="UTF-8"?>
|
|
|
+<?xml-stylesheet type="text/xsl" href="odmlTerms.xsl"?>
|
|
|
+<?xml-stylesheet type="text/xsl" href="odml.xsl"?>
|
|
|
+<odML xmlns:gui="http://www.g-node.org/guiml" version="1">
|
|
|
+ <version>1</version>
|
|
|
+ <date>2015-07-16</date>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Experiment</name>
|
|
|
+ <property>
|
|
|
+ <name>start-time</name>
|
|
|
+ <gui:required>true</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ 01.03.2011, 17:00:00
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>end-time</name>
|
|
|
+ <gui:required>true</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ 01.03.2011, 17:40:00
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>research-group</name>
|
|
|
+ <gui:required>true</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>2</gui:order>
|
|
|
+ <value>
|
|
|
+ EEG_Janak_Attention
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>scenario-title</name>
|
|
|
+ <gui:required>true</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>3</gui:order>
|
|
|
+ <value>
|
|
|
+ Driver's attention and visual stimulation
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Experimenters</name>
|
|
|
+ <property>
|
|
|
+ <name>Experimenter #1</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ Ing. Pavel Mautner, Ph.D.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Experimenter #2</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ Ing. Roman Mouček, Ph.D.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Subject</name>
|
|
|
+ <property>
|
|
|
+ <name>Gender</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ male
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ <value>
|
|
|
+ female
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Age</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ 21
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Digitization</name>
|
|
|
+ <property>
|
|
|
+ <name>Sampling-rate</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ 1000 Hz
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Hardware</name>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>EEG cap</name>
|
|
|
+ <property>
|
|
|
+ <name>Type</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ Medium, 54 - 58 cm (red)
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ <value>
|
|
|
+ Large, 58 - 62 cm (dark blue)
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ <value>
|
|
|
+ Small, 50 - 54 cm (yellow)
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ EEG cap captures the signal of neuronal activity in the brain from the head surface using electrode application technique.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Inventory number</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>2</gui:order>
|
|
|
+ <value>
|
|
|
+ 17196
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ <value>
|
|
|
+ 21050
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ <value>
|
|
|
+ 16884
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Manufacturer</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>3</gui:order>
|
|
|
+ <value>
|
|
|
+ Electro-Cap International, Inc. Eaton, Ohio 45320 USA
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Electrode</name>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ An electrode is an electrical conductor used to make contact with a nonmetallic part of a circuit (e.g., the human scalp) and is used to measure electrical activity. http://purl.bioontology.org/NEMO/ontology/NEMO.owl#NEMO_0000501
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Eye Blink Detection Electrode</name>
|
|
|
+ <property>
|
|
|
+ <name>Title</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ E21-9S DISK ELECTRODE
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ A pure tin cup electrode with a 48" (122 cm) lead wire and a female socket. Device is used as a reference electrode.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Owner</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>2</gui:order>
|
|
|
+ <value>
|
|
|
+ Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Type</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>3</gui:order>
|
|
|
+ <value>
|
|
|
+ Standard 9mm cup
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Manufacturer</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>4</gui:order>
|
|
|
+ <value>
|
|
|
+ Electro-Cap International, Inc. Eaton, Ohio 45320 USA
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Reference</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>5</gui:order>
|
|
|
+ <value>
|
|
|
+ http://www.electro-cap.com/index.cfm/supplies/
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Reference Electrode</name>
|
|
|
+ <property>
|
|
|
+ <name>Title</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ E21-9S DISK ELECTRODE
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ A pure tin cup electrode with a 48" (122 cm) lead wire and a female socket. Device is used as a reference electrode.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Owner</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>2</gui:order>
|
|
|
+ <value>
|
|
|
+ Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Type</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>3</gui:order>
|
|
|
+ <value>
|
|
|
+ Standard 9mm cup
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Manufacturer</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>4</gui:order>
|
|
|
+ <value>
|
|
|
+ Electro-Cap International, Inc. Eaton, Ohio 45320 USA
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Reference</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>5</gui:order>
|
|
|
+ <value>
|
|
|
+ http://www.electro-cap.com/index.cfm/supplies/
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Ground Electrode</name>
|
|
|
+ <property>
|
|
|
+ <name>Title</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ E5-9S EAR ELECTRODE
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ A pair of pure tin cup electrodes with a 48" (122 cm) lead wire and a female socket. A spring-clip back, covered with plastic for patient comfort, is used to hold the electrode in place. Device is used as a ground electrode.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Owner</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>2</gui:order>
|
|
|
+ <value>
|
|
|
+ Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Type</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>3</gui:order>
|
|
|
+ <value>
|
|
|
+ Standard 9mm cup
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Manufacturer</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>4</gui:order>
|
|
|
+ <value>
|
|
|
+ Electro-Cap International, Inc. Eaton, Ohio 45320 USA
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Reference</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>5</gui:order>
|
|
|
+ <value>
|
|
|
+ http://www.electro-cap.com/index.cfm/supplies/
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Car simulator</name>
|
|
|
+ <property>
|
|
|
+ <name>Stimulatory light</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ A light-emitting diode (LED) is a semiconductor light source.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Bodywork</name>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ Bodywork is the body of a motor vehicle (automobile, bus or truck), a horse-drawn coach or carriage (whence the term originated), or, by extension, a railroad car or railway carriage. An obsolescent synonym is carrossery.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Car model</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ Skoda Octavia - is a brand of the car bodywork used for our experimental car.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Steering wheel</name>
|
|
|
+ <property>
|
|
|
+ <name>Type</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ G27 Racing Wheel Steering wheel
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ A game wheel that controls steering, as in the car simulator. Device is used for measuring driver´s experiments.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Pedals</name>
|
|
|
+ <property>
|
|
|
+ <name>Type</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ G27 Racing Wheel pedals
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ G27 Racing Wheel pedals device has the steel gas, brake, and clutch pedals deliver precise throttle, braking, and shifting control for heightened realism.Device is used for measuring driver´s experiments.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Shifter</name>
|
|
|
+ <property>
|
|
|
+ <name>Type</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ G27 Racing Wheel shifter
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ G27 Racing Wheel shifter is a six-speed shifter used for shift gears in driver´s experiments.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Digital projector</name>
|
|
|
+ <property>
|
|
|
+ <name>Type</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ The Acer P5280
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ The Acer P5280 is a digital projector used for projection of stimulation protokol.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Sound system</name>
|
|
|
+ <property>
|
|
|
+ <name>Type</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ Logitech X140
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ Total RMS power: 5 watts RMS (2.5 x 2) Total peak power: 10 watts Frequency response: 80Hz - 18kHz 7 cm high-excursion driver with 7.6 cm pressure driver Speaker dimensions 24.1 x 9.9 x 12.4 (H x W x D, cm)
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Camera system</name>
|
|
|
+ <property>
|
|
|
+ <name>Type</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ HD Pro Webcam C920
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ Full HD 1080p video calling (up to 1920 x 1080 pixels) with the latest version of Skype for Windows* 720p HD video calling (up to 1280 x 720 pixels) with supported clients Full HD video recording (up to 1920 x 1080 pixels) with a recommended system** Logitech Fluid Crystal™ Technology H.264 video compression* Carl Zeiss® lens with 20-step autofocus Built-in dual stereo mics with automatic noise reduction Automatic low-light correction Hi-Speed USB 2.0 certified (USB 3.0 ready) Tripod-ready universal clip fits laptops, LCD or CRT monitors
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Amplifier</name>
|
|
|
+ <property>
|
|
|
+ <name>Title</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ V-Amp 16
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Type</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ digital DC amplifier input 5V DC, 450mA
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>2</gui:order>
|
|
|
+ <value>
|
|
|
+ The V-Amp is used for recording EEG signal and the full range of evoked potentials. Amplifier has two auxiliary ports for measuring peripheral signals like GSR, blood flow, body temperature.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Serial number</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>3</gui:order>
|
|
|
+ <value>
|
|
|
+ AMP 10021151 VA16
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Inventory number</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>4</gui:order>
|
|
|
+ <value>
|
|
|
+ 501421
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Owner</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>5</gui:order>
|
|
|
+ <value>
|
|
|
+ Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Number of channels</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>6</gui:order>
|
|
|
+ <value>
|
|
|
+ 18
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Manufacturer</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>7</gui:order>
|
|
|
+ <value>
|
|
|
+ Brain Products
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Reference</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>8</gui:order>
|
|
|
+ <value>
|
|
|
+ http://www.brainproducts.com/productdetails.php?id=15
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Stimulation computer</name>
|
|
|
+ <property>
|
|
|
+ <name>Type</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ HP station
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ Stimulation computer used processor Intel Xeon E5 1650 3,5 GHz. It has 16 GB RAM. Stimulation computer is used for playing stimulation protocol.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Recording computer</name>
|
|
|
+ <property>
|
|
|
+ <name>Type</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ Notebook DELL LATITUDE
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ Recording computer used processor Intel Core i7 CPU 3,2GHz 3,19GHz. It has 12 GB RAM. Device is used for recording EEG/ERP from drivers or mice blindness expreriments.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Auditory presentation computer</name>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ Auditory presentation computer used processor Intel Core i7 CPU 2,67GHz 2,67GHz. It has 12 GB RAM. Stimulation computer is used for playing stimulation protocol.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Accessories</name>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Electro Gel</name>
|
|
|
+ <property>
|
|
|
+ <name>Title</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ ELECTRO-GEL NET:16
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ This electro-gel is an off white color, water-miscible conductive gel. Electro-gel is a mixture of the following components: Water, Sodium Chloride, Aragum, Glycerin, Pottasium Bitartrate, Methylparaben and Propylparaben. Electro gel is applied by inserting the gel into the EEG cap electrodes by using a syringe and blunted needle. Electro gel is used for setting low electrode impedance and limitations of electrode artifacts.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Manufacturer</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>2</gui:order>
|
|
|
+ <value>
|
|
|
+ ELECTRO-Cap International, Inc. 1011 W. Lexington Road Eaton, Ohio 45320 U.S.A.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Conductive Paste</name>
|
|
|
+ <property>
|
|
|
+ <name>Title</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ Ten 20 CONDUCTIVE EEG Paste
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ Ten20 is a conductive and adhesive paste specifically formulated for use with reusable (non-disposable) electrodes. Primarily used for EEG electrodes. (http://www.biopac.com/ten20-conductivegel)
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Manufacturer</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>2</gui:order>
|
|
|
+ <value>
|
|
|
+ Weaver and Company 565 Nucla Way Unit B Aurora, CO 80011 Toll Free 800-525-2130 Fax 303-367-5118
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Degreasing Gel</name>
|
|
|
+ <property>
|
|
|
+ <name>Title</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ Nuprep
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ Nuprep gel is applied to electrode site on scalp with cotton swab. EEG electrode paste and reference or ground electrode is applied over Nuprep gel.
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Manufacturer</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>2</gui:order>
|
|
|
+ <value>
|
|
|
+ Weaver and Company 565 Nucla Way Unit B Aurora, CO 80011 Toll Free 800-525-2130 Fax 303-367-5118
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+ </section>
|
|
|
+ <section>
|
|
|
+ <type>new</type>
|
|
|
+ <name>Software</name>
|
|
|
+ <property>
|
|
|
+ <name>Title</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>0</gui:order>
|
|
|
+ <value>
|
|
|
+ BrainVision Recorder 1.2
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ <property>
|
|
|
+ <name>Description</name>
|
|
|
+ <gui:required>false</gui:required>
|
|
|
+ <gui:editable>true</gui:editable>
|
|
|
+ <gui:order>1</gui:order>
|
|
|
+ <value>
|
|
|
+ EEG/ERP recording software
|
|
|
+ <type>string</type>
|
|
|
+ </value>
|
|
|
+ </property>
|
|
|
+ </section>
|
|
|
+</odML>
|
|
|
+
|