sub-C149/sub-C149_FLAIRw.json

@@ -0,0 +1,61 @@
+{
+	"Modality": "MR",
+	"MagneticFieldStrength": 3,
+	"ImagingFrequency": 127.761,
+	"Manufacturer": "Philips",
+	"ManufacturersModelName": "Ingenia",
+	"InstitutionName": "Portico 3T MRI",
+	"InstitutionalDepartmentName": "MRI",
+	"DeviceSerialNumber": "42214",
+	"StationName": "PHILIPS-A912C29",
+	"BodyPartExamined": "BRAIN",
+	"PatientPosition": "HFS",
+	"ProcedureStepDescription": "MRI, brain functional",
+	"SoftwareVersions": "5.4.1\\5.4.1.2",
+	"MRAcquisitionType": "3D",
+	"SeriesDescription": "3D_FLAIR",
+	"ProtocolName": "3D_FLAIR",
+	"ScanningSequence": "IR",
+	"SequenceVariant": "SK",
+	"ScanOptions": "OTHER",
+	"ImageType": ["ORIGINAL", "PRIMARY", "M", "IR", "M", "IR"],
+	"SeriesNumber": 402000,
+	"AcquisitionTime": "06:48:1.360000",
+	"AcquisitionNumber": 4,
+	"PhilipsRWVSlope": 3.9431,
+	"PhilipsRWVIntercept": 0,
+	"PhilipsRescaleSlope": 3.9431,
+	"PhilipsRescaleIntercept": 0,
+	"PhilipsScaleSlope": 0.00132884,
+	"UsePhilipsFloatNotDisplayScaling": 1,
+	"SliceThickness": 1.2,
+	"SpacingBetweenSlices": 0.6,
+	"SAR": 0.488862,
+	"NumberOfAverages": 2,
+	"EchoTime": 0.273129,
+	"RepetitionTime": 4.8,
+	"InversionTime": 1.65,
+	"FlipAngle": 90,
+	"CoilString": "MULTI COIL",
+	"PercentPhaseFOV": 96.2963,
+	"PercentSampling": 78.5398,
+	"EchoTrainLength": 167,
+	"PhaseEncodingSteps": 192,
+	"AcquisitionMatrixPE": 192,
+	"ReconMatrixPE": 432,
+	"WaterFatShift": 0.386997,
+	"EstimatedEffectiveEchoSpacing": 2.05475e-06,
+	"EstimatedTotalReadoutTime": 0.000885597,
+	"PixelBandwidth": 1122,
+	"PhaseEncodingAxis": "j",
+	"ImageOrientationPatientDICOM": [
+		0.999368,
+		-0.0331383,
+		-0.0128569,
+		0.0331413,
+		0.999451,
+		2.00895e-05	],
+	"InPlanePhaseEncodingDirectionDICOM": "COL",
+	"ConversionSoftware": "dcm2niix",
+	"ConversionSoftwareVersion": "v1.0.20210317"
+}

+ 1 - 0
sub-C149/sub-C149_FLAIRw.nii

@@ -0,0 +1 @@
+/annex/objects/MD5-s104509792--5d8684e5cd6619f78c8af758d73cbefe

+ 59 - 0
sub-C149/sub-C149_T1w.json

@@ -0,0 +1,59 @@
+{
+	"Modality": "MR",
+	"MagneticFieldStrength": 3,
+	"ImagingFrequency": 127.761,
+	"Manufacturer": "Philips",
+	"ManufacturersModelName": "Ingenia",
+	"InstitutionName": "Portico 3T MRI",
+	"InstitutionalDepartmentName": "MRI",
+	"DeviceSerialNumber": "42214",
+	"StationName": "PHILIPS-A912C29",
+	"BodyPartExamined": "BRAIN",
+	"PatientPosition": "HFS",
+	"ProcedureStepDescription": "MRI, brain functional",
+	"SoftwareVersions": "5.4.1\\5.4.1.2",
+	"MRAcquisitionType": "3D",
+	"SeriesDescription": "3D T1 PRE",
+	"ProtocolName": "3D T1 PRE",
+	"ScanningSequence": "GR",
+	"SequenceVariant": "MP",
+	"ScanOptions": "OTHER",
+	"ImageType": ["ORIGINAL", "PRIMARY", "M", "FFE", "M", "FFE"],
+	"SeriesNumber": 302000,
+	"AcquisitionTime": "06:44:35.570000",
+	"AcquisitionNumber": 3,
+	"PhilipsRWVSlope": 3.37094,
+	"PhilipsRWVIntercept": 0,
+	"PhilipsRescaleSlope": 3.37094,
+	"PhilipsRescaleIntercept": 0,
+	"PhilipsScaleSlope": 0.00382037,
+	"UsePhilipsFloatNotDisplayScaling": 1,
+	"SliceThickness": 1.1,
+	"SpacingBetweenSlices": 0.55,
+	"SAR": 0.238512,
+	"EchoTime": 0.003435,
+	"RepetitionTime": 0.0075152,
+	"FlipAngle": 8,
+	"CoilString": "MULTI COIL",
+	"PercentPhaseFOV": 100,
+	"PercentSampling": 77.8258,
+	"EchoTrainLength": 227,
+	"PhaseEncodingSteps": 218,
+	"AcquisitionMatrixPE": 218,
+	"ReconMatrixPE": 432,
+	"WaterFatShift": 2.07951,
+	"EstimatedEffectiveEchoSpacing": 1.10585e-05,
+	"EstimatedTotalReadoutTime": 0.0047662,
+	"PixelBandwidth": 209,
+	"PhaseEncodingAxis": "i",
+	"ImageOrientationPatientDICOM": [
+		0.0331413,
+		0.999451,
+		2.00895e-05,
+		-0.0128491,
+		0.000446169,
+		-0.999917	],
+	"InPlanePhaseEncodingDirectionDICOM": "ROW",
+	"ConversionSoftware": "dcm2niix",
+	"ConversionSoftwareVersion": "v1.0.20210317"
+}