123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191 |
- Brain Vision Data Exchange Header File Version 1.0
- ; Data created by the Vision Recorder
- [Common Infos]
- Codepage=UTF-8
- DataFile=230_oddball.eeg
- MarkerFile=230_oddball.vmrk
- DataFormat=BINARY
- ; Data orientation: MULTIPLEXED=ch1,pt1, ch2,pt1 ...
- DataOrientation=MULTIPLEXED
- NumberOfChannels=32
- ; Sampling interval in microseconds
- SamplingInterval=2000
- [Binary Infos]
- BinaryFormat=IEEE_FLOAT_32
- [Channel Infos]
- ; Each entry: Ch<Channel number>=<Name>,<Reference channel name>,
- ; <Resolution in "Unit">,<Unit>, Future extensions..
- ; Fields are delimited by commas, some fields might be omitted (empty).
- ; Commas in channel names are coded as "\1".
- Ch1=Fp1,,0.0406901,µV
- Ch2=Fz,,0.0406901,µV
- Ch3=F3,,0.0406901,µV
- Ch4=F7,,0.0406901,µV
- Ch5=FT9,,0.0406901,µV
- Ch6=FC5,,0.0406901,µV
- Ch7=FC1,,0.0406901,µV
- Ch8=C3,,0.0406901,µV
- Ch9=T7,,0.0406901,µV
- Ch10=TP9,,0.0406901,µV
- Ch11=CP5,,0.0406901,µV
- Ch12=CP1,,0.0406901,µV
- Ch13=Pz,,0.0406901,µV
- Ch14=P3,,0.0406901,µV
- Ch15=P7,,0.0406901,µV
- Ch16=O1,,0.0406901,µV
- Ch17=Oz,,0.0406901,µV
- Ch18=O2,,0.0406901,µV
- Ch19=P4,,0.0406901,µV
- Ch20=P8,,0.0406901,µV
- Ch21=TP10,,0.0406901,µV
- Ch22=CP6,,0.0406901,µV
- Ch23=CP2,,0.0406901,µV
- Ch24=Cz,,0.0406901,µV
- Ch25=C4,,0.0406901,µV
- Ch26=T8,,0.0406901,µV
- Ch27=FT10,,0.0406901,µV
- Ch28=FC6,,0.0406901,µV
- Ch29=FC2,,0.0406901,µV
- Ch30=F4,,0.0406901,µV
- Ch31=F8,,0.0406901,µV
- Ch32=Fp2,,0.0406901,µV
- [Coordinates]
- ; Electrode Position File: C:\Users\admin-local\Desktop\actiCAP for LiveAmp 32 Channel\CLA-32.bvef
- Ch1=1,-90,-72
- Ch2=1,45,90
- Ch3=1,-60,-51
- Ch4=1,-90,-36
- Ch5=1,-113,-18
- Ch6=1,-69,-22
- Ch7=1,-31,-46
- Ch8=1,-45,0
- Ch9=1,-90,0
- Ch10=1,-113,18
- Ch11=1,-69,21
- Ch12=1,-31,46
- Ch13=1,45,-90
- Ch14=1,-60,51
- Ch15=1,-90,36
- Ch16=1,-90,72
- Ch17=1,90,-90
- Ch18=1,90,-72
- Ch19=1,60,-51
- Ch20=1,90,-36
- Ch21=1,113,-18
- Ch22=1,69,-21
- Ch23=1,31,-46
- Ch24=1,0,0
- Ch25=1,45,0
- Ch26=1,90,0
- Ch27=1,113,18
- Ch28=1,69,21
- Ch29=1,31,46
- Ch30=1,60,51
- Ch31=1,90,36
- Ch32=1,90,72
- [Comment]
- BrainVision Recorder Professional - V. 1.21.0303
- A m p l i f i e r S e t u p
- ============================
- Number of channels: 32
- Sampling Rate [Hz]: 500
- Sampling Interval [µS]: 2000
- Channels
- --------
- # Name Phys. Chn. Resolution / Unit Low Cutoff [s] High Cutoff [Hz] Notch [Hz] Gradient Offset
- 1 Fp1 1 0.0406901 µV DC 131 Off
- 2 Fz 2 0.0406901 µV DC 131 Off
- 3 F3 3 0.0406901 µV DC 131 Off
- 4 F7 4 0.0406901 µV DC 131 Off
- 5 FT9 5 0.0406901 µV DC 131 Off
- 6 FC5 6 0.0406901 µV DC 131 Off
- 7 FC1 7 0.0406901 µV DC 131 Off
- 8 C3 8 0.0406901 µV DC 131 Off
- 9 T7 9 0.0406901 µV DC 131 Off
- 10 TP9 10 0.0406901 µV DC 131 Off
- 11 CP5 11 0.0406901 µV DC 131 Off
- 12 CP1 12 0.0406901 µV DC 131 Off
- 13 Pz 13 0.0406901 µV DC 131 Off
- 14 P3 14 0.0406901 µV DC 131 Off
- 15 P7 15 0.0406901 µV DC 131 Off
- 16 O1 16 0.0406901 µV DC 131 Off
- 17 Oz 17 0.0406901 µV DC 131 Off
- 18 O2 18 0.0406901 µV DC 131 Off
- 19 P4 19 0.0406901 µV DC 131 Off
- 20 P8 20 0.0406901 µV DC 131 Off
- 21 TP10 21 0.0406901 µV DC 131 Off
- 22 CP6 22 0.0406901 µV DC 131 Off
- 23 CP2 23 0.0406901 µV DC 131 Off
- 24 Cz 24 0.0406901 µV DC 131 Off
- 25 C4 25 0.0406901 µV DC 131 Off
- 26 T8 26 0.0406901 µV DC 131 Off
- 27 FT10 27 0.0406901 µV DC 131 Off
- 28 FC6 28 0.0406901 µV DC 131 Off
- 29 FC2 29 0.0406901 µV DC 131 Off
- 30 F4 30 0.0406901 µV DC 131 Off
- 31 F8 31 0.0406901 µV DC 131 Off
- 32 Fp2 32 0.0406901 µV DC 131 Off
- LiveAmp SN: LA-056309-0523
- LiveAmp hardware revision: 5
- Firmware version: 4.71
- Sensor and trigger extension SN: STE-056305-0185
- Sensor and trigger extension hardware revision: 1
- Sensor and trigger extension firmware version: 1.14
- Library version: 9.17.10.12
- Use Active/Dry Electrodes: Yes
- S o f t w a r e F i l t e r s
- ==============================
- Disabled
- Data/Gnd/Ref Electrodes Selected Impedance Measurement Range: 25 - 60 kOhm
- Impedance [kOhm] at 10:24:59 :
- Fp1: 0
- Fz: 13
- F3: 16
- F7: 18
- FT9: 17
- FC5: 17
- FC1: 5
- C3: 4
- T7: 19
- TP9: 17
- CP5: 16
- CP1: 5
- Pz: 4
- P3: 9
- P7: 14
- O1: 16
- Oz: 4
- O2: 2
- P4: 18
- P8: 18
- TP10: 11
- CP6: 16
- CP2: 24
- Cz: 4
- C4: 16
- T8: 15
- FT10: 15
- FC6: 13
- FC2: 1
- F4: 11
- F8: 2
- Fp2: 0
- Gnd: 0
- Ref: 10
|