This a light version of a visual motion localizer dataset used for praticals and workshop sessions.

Remi Gau a412abae41 add DS store to gitignore vor 11 Monaten
.datalad 22036138b1 Configure metadata type(s) vor 1 Jahr
code c65d45623a save vor 1 Jahr
derivatives 172cd918f5 zip niftis vor 1 Jahr
sub-con07 1a792f6891 reinitialize dataset vor 2 Jahren
sub-con08 1a792f6891 reinitialize dataset vor 2 Jahren
sub-con15 1a792f6891 reinitialize dataset vor 2 Jahren
.bids-validator-config.json 1a792f6891 reinitialize dataset vor 2 Jahren
.bidsignore 1a792f6891 reinitialize dataset vor 2 Jahren
.gitattributes fb1f5f3648 update dataset config vor 11 Monaten
.gitignore a412abae41 add DS store to gitignore vor 11 Monaten
.gitmodules e551001b31 change subdataset url vor 2 Jahren
CHANGES 1a792f6891 reinitialize dataset vor 2 Jahren
README.md 7efa46f408 update summary image vor 2 Jahren
dataset_description.json 1a792f6891 reinitialize dataset vor 2 Jahren
participants.tsv 1a792f6891 reinitialize dataset vor 2 Jahren
task-visMotion_bold.json 1a792f6891 reinitialize dataset vor 2 Jahren

README.md

Data description

This a light version of a visual motion localizer data set used for pratical sessions.

Content

    Summary:                 Available Tasks:        Available Modalities:
    16 Files, 547.4MB        visMotion               MRI
    3 - Subjects
    1 - Session

Anatomical Magnetic Resonance Imaging data

T1-weighted image

The data acquisition was performed in the York_MRI_Facility, Department, Keel_Street_4700_Toronto_Ontario_CA_M3J_1P3.

MRI scans were acquired at 3 Tesla using a Prisma_fit system from Siemens, with serial number 167057. The software version was syngo_MR_E11.

{{PulseSequenceType}} GR_IR SK_SP_MP T1w structural MRI data were collected (256 slices; repetition time, TR= 2.3 s; echo time, TE= 0.00262 s; flip angle, FA= 9 deg; field of view, FOV= 192 X 256 mm; matrix size= 192 X 256; voxel size= 1.00 X 1.00 X 1.00 mm).

Task-Based Magnetic Resonance Imaging data

BOLD data

Task visMotion data

The data acquisition was performed in the York_MRI_Facility, Department, Keel_Street_4700_Toronto_Ontario_CA_M3J_1P3.

MRI scans were acquired at 3 Tesla using a Prisma_fit system from Siemens, with serial number 167057. The software version was syngo_MR_E11.

For the visMotion task, 1 run(s) of bold {{PulseSequenceType}} EP SK fMRI data were collected. The acquisition parameters were: 51 slices acquired in a interleaved ascending fashion; repetition time, TR= 1.17 s; echo time, TE= 0.03 s; flip angle, FA= 66 deg; field of view, FOV= 240 X 239 mm; matrix size= 120 X 120; voxel size= 2.00 X 1.99 X 1.99 mm; multiband factor= 3; in-plane acceleration factor= {pr_str}}. Each run was 4.914 minutes in length, during which 252 functional volumes were acquired.

{{TaskDescription}} Participants were specifically instructed to: {{Instructions}}

events data

This text was automatically generated by BIDS-matlab.