Scheduled service maintenance on November 22


On Friday, November 22, 2024, between 06:00 CET and 18:00 CET, GIN services will undergo planned maintenance. Extended service interruptions should be expected. We will try to keep downtimes to a minimum, but recommend that users avoid critical tasks, large data uploads, or DOI requests during this time.

We apologize for any inconvenience.

Heberto Mayorquin 8d1aaa971e gin commit from h-laptop 2 месяцев назад
..
4chDemoPL2.pl2 6f4d1a5e95 gin commit from nit-ope-de04 1 год назад
4chDemoPLX.plx a47c008c53 gin commit from h-laptop 3 месяцев назад
File_plexon_1.plx e5dbc29dfd gin commit from hambach37 3 лет назад
File_plexon_2.plx e5dbc29dfd gin commit from hambach37 3 лет назад
File_plexon_3.plx e5dbc29dfd gin commit from hambach37 3 лет назад
NC16FPSPKEVT_1m.pl2 8d1aaa971e gin commit from h-laptop 2 месяцев назад
README.md d3c6ce9354 gin commit from h-laptop 2 месяцев назад

README.md

Format test files from Plexon electrophysiology recording systems

Plexon 1 files

FilePlexon{}.plx

Plexon 1 files. Some comments on them:

  • Plexon 1: does not have signal channels, only spikes
  • Plexon 2: does not have signa channels, only spikes
  • Plexon 3: has only one signal channel with channel name "V1"

4chDemoPLX.plx

Taken from the Plexon site same as above but in PLX (plexon 1) format.

Plexon 2 files

4chDemoPL2.pl2

This file is taken from the Plexon website and contains data of a four channel tetrode: PL2 file with one tetrode channel of sorted spikes, continuous wideband, and continuous field potentials. 16 channels of events. One channel of strobed data that increments in value from 32513 to 32767. One channel of auxiliary analog input. See also the data samples provided by plexon

NC16FPSPKEVT_1m.pl2

This file was contributed by Nikhil Chandra. The following is his description:

The rig I used to generate this file had 16 channels. While setting up the recording session, I cycled through the four possible combinations of m_ChannelEnabled and m_ChannelRecordingEnabled for FP (analog) and SPK (spike) recording streams. This means there should be 4 channels’ worth of FP and SPK data (channels 1, 5, 9, and 13, I think). For EVT, it turns out that the ability to set the enabled flags is not exposed through the UI, so they’re always set to True. The file has 16 channels of event data. I am not sure yet whether I will include these event channels in the test.

The recording lasts 1 minute

For a discussiong about the origins of this file refer to this PR in python neo: https://github.com/NeuralEnsemble/python-neo/pull/1546

datacite.yml
Title Electrophysiology Testing Data
Authors Sprenger,Julia;Institut de Neurosciences de La Timone, CNRS & Aix-Marseille University, Marseille, France;ORCID:0000-0002-9986-7477
Garcia,Samuel;Centre de Recherche en Neuroscience de Lyon, CNRS, Lyon, France;ORCID:0000-0001-6389-9779
Description Collection of testing data in various electrophysiology file formats.
License Open Data Commons Open Database License (ODbL) (https://opendatacommons.org/licenses/odbl/1.0/)
References Neo (RRID:SCR_000634) [RRID:SCR_000634] (IsSupplementTo)
SpikeInterface (RRID:SCR_021150) [RRID:SCR_021150] (IsSupplementTo)
Funding
Keywords Neuroscience
File Format
Test Data
Resource Type Dataset