  1. {
  2. "Modality": "MR",
  3. "MagneticFieldStrength": 6.98,
  4. "ImagingFrequency": 297.188,
  5. "Manufacturer": "Siemens",
  6. "ManufacturersModelName": "Investigational_Device_7T",
  7. "InstitutionName": "CUBRIC",
  8. "InstitutionalDepartmentName": "Department",
  9. "InstitutionAddress": "Maindy Rd -,Cardiff -76A68D-,Wales,GB,CF244HQ",
  10. "DeviceSerialNumber": "18984",
  11. "StationName": "MRC18984",
  12. "PatientPosition": "HFS",
  13. "ProcedureStepDescription": "7Tproj^314_WAND",
  14. "SoftwareVersions": "syngo MR B17",
  15. "MRAcquisitionType": "3D",
  16. "SeriesDescription": "MP2RAGE_UK7T_081018_tfl_wip944_b17stx_RR_UniformSens_MAGinv2",
  17. "ProtocolName": "MP2RAGE_UK7T_081018_tfl_wip944_b17stx",
  18. "ScanningSequence": "GR\\IR",
  19. "SequenceVariant": "SP\\MP",
  20. "ScanOptions": "IR",
  21. "SequenceName": "tfl3d1_ns",
  22. "ImageType": [
  23. "ORIGINAL",
  24. "PRIMARY",
  25. "M",
  26. "ND"
  27. ],
  28. "NonlinearGradientCorrection": false,
  29. "SeriesNumber": 165,
  30. "AcquisitionTime": "14:46:7.440000",
  31. "AcquisitionNumber": 1,
  32. "ImageComments": "Uniform Sensitivity\r\n314_77660/19940724/19.02.27-14:14:08-STD-1.3.12.2.1107.5.2.34.18984/2",
  33. "SliceThickness": 0.7,
  34. "EchoTime": 0.00264,
  35. "RepetitionTime": 3.5,
  36. "InversionTime": 2.15,
  37. "FlipAngle": 2,
  38. "PartialFourier": 1,
  39. "BaseResolution": 320,
  40. "ShimSetting": [
  41. 31,
  42. 36,
  43. 888,
  44. 200,
  45. -3,
  46. -209,
  47. -2,
  48. -97
  49. ],
  50. "TxRefAmp": 269,
  51. "PhaseResolution": 1,
  52. "ReceiveCoilName": "32Ch_Head_7T",
  53. "CoilString": "C:A32",
  54. "PulseSequenceDetails": "%CustomerSeq%\\tfl_wip944_b17stx",
  55. "RefLinesPE": 40,
  56. "CoilCombinationMethod": "Adaptive Combine",
  57. "MatrixCoilMode": "GRAPPA",
  58. "PercentPhaseFOV": 100,
  59. "PercentSampling": 100,
  60. "PhaseEncodingSteps": 320,
  61. "AcquisitionMatrixPE": 320,
  62. "ReconMatrixPE": 320,
  63. "ParallelReductionFactorInPlane": 3,
  64. "PixelBandwidth": 300,
  65. "DwellTime": 5.2e-06,
  66. "ImageOrientationPatientDICOM": [
  67. 0,
  68. 1,
  69. 0,
  70. 0,
  71. 0,
  72. -1
  73. ],
  74. "ImageOrientationText": "Sag",
  75. "InPlanePhaseEncodingDirectionDICOM": "ROW",
  76. "ConversionSoftware": "dcm2niix",
  77. "ConversionSoftwareVersion": "v1.0.20220720",
  78. "Dcm2bidsVersion": "2.1.7"
  79. }