1 2015-07-16
experiment Experiment private-experiment false true 0 false string start-time false true 1 17.12.2013, 10:08:00 string end-time false true 2 17.12.2013, 10:28:00 string temperature false true 3 23 string environment-note false true 4 research-group false true 5 Developmental Coordination Disorder string scenario-title false true 6 AUDITORY ERP PROTOCOL IN CHILDREN WITH DEVELOPMENTAL COORDINATION DISORDER string
person Subject gender false true 0 F string age (years, months) false true 1 8y 7m string comorbidities false true 2 no string laterality false true 3 right-handed string myopia false true 4 no string
weather Weather title false true 0 Sunny string description false true 1 Sunny weather string
collection Devices
hardware Response button description false true 0 "A response button is an electrical component that can break an electrical circuit, interrupting the current or diverting it from one conductor to another. A switch is used by a tested subject as a control signal (response) for a stimulation system." 
http://en.wikipedia.org/wiki/Switch string
hardware Power supply type false true 0 PS607110246wr string description false true 1 The component that supplies power to a amplifier. (http://www.webopedia.com/TERM/P/power_supply.html) string
hardware Reference electrode type false true 0 E21-9S DISK ELECTRODE string description false true 1 A pure tin cup electrode with a 48" (122 cm) lead wire and a female socket. Device is used as a reference electrode, and is located at the root of the nose. string
hardware Small EEG cap type false true 0 HEAD CIRCUMFERENCE: 50 - 54 cm string description false true 1 EEG cap captures the signal of neuronal activity in the brain from the head surface using electrode application technique. string
hardware Digital Portable - Real Hardware-mixer title false true 0 Digital PortaStudio 564 string type false true 1 PortaStudio564 string description false true 2 Device is used for audio stimulation of tested subject within EEG stimulation protocol. string
hardware Ground electrode title false true 0 E5-9S EAR ELECTRODE string description false true 1 A pair of pure tin cup electrodes with a 48" (122 cm) lead wire and a female socket. A spring-clip back, covered with plastic for patient comfort, is used to hold the electrode in place.Device is used as a ground electrode. string
hardware Amplifier title false true 0 BRAIN AMP DC string type false true 1 AMP0711758DC string description false true 2 The BrainAmp DC includes all the outstanding features of the BrainAmp amplifier with the addition of the DC recording mode as well as with multiple hardware filtering options. The setup of the amplifier is fully controllable via the recording software. string
hardware USB 2 adapter type false true 0 USB 2 string description false true 1 Hardware device which provides an interface between an amplifier (optic fiber) and computer (USB2). string
hardware Headphones type false true 0 Circumaural headphones string description false true 1 Device is used for audio stimulation of tested subject within EEG stimulation protocol. string
hardware Clinical audiometer type false true 0 DA74 string description false true 1 An audiometer is a machine used for evaluating hearing mechanism. (http://en.wikipedia.org/wiki/Audiometer) string
hardware ELECTRODE INPUT BOX 64 CHANNEL type false true 0 EIB06031122 string description false true 1 64-channel Electrode Input Box is a device that only allowed electrodes with single-input safety sockets to be connected to the BrainAmp recording amplifiers. string
hardware Sound-proof cabin type false true 0 2x2x1,5m string description false true 1 Closable cabin formed by conducting material for one person (approx 2x2x1,5m) which muffle external noise. Cabin blocks external static and non-static electric fields by channeling electricity through conducting material and provides constant voltage on all sides of the cabin. Subject inside is screened out from events in the lab during the experiment. The cabin contains ventilation, light and window.
http://en.wikipedia.org/wiki/Faraday_cage string
collection Softwares
software Presentation description false true 0 Presentation is a stimulus delivery and experimental control program for neuroscience. Program delivers auditory, visual and multimodal stimuli with sub-millisecond temporal precision. string
software BrainVision Recorder 1.2 description false true 0 The BrainVision Recorder is used to control EEG amplifiers and record EEG signals. string
collection ProjectTypes
projectType ProjectType title false true 0 Grant Agency of the Czech Republic string description false true 1 This work was supported by the Grant Agency of the Czech Republic under the grant P407/12/1525. string
collection Experimentators
person Person surname true true 0 Vareka string givenname true true 1 Lukas string gender true true 2 M string
person Person1 surname true true 0 Mautner string givenname true true 1 Pavel string gender true true 2 M string
person Person2 surname true true 0 Bruha string givenname true true 1 Petr string gender true true 2 M string
person Person3 surname true true 0 Mouček string givenname true true 1 Roman string gender true true 2 M string