1
2015-07-16
experiment
Experiment
private-experiment
false
true
0
false
string
start-time
false
true
1
17.12.2013, 10:08:00
string
end-time
false
true
2
17.12.2013, 10:28:00
string
temperature
false
true
3
23
string
environment-note
false
true
4
research-group
false
true
5
Developmental Coordination Disorder
string
scenario-title
false
true
6
AUDITORY ERP PROTOCOL IN CHILDREN WITH DEVELOPMENTAL COORDINATION DISORDER
string
person
Subject
gender
false
true
0
F
string
age (years, months)
false
true
1
8y 7m
string
comorbidities
false
true
2
no
string
laterality
false
true
3
right-handed
string
myopia
false
true
4
no
string
weather
Weather
title
false
true
0
Sunny
string
description
false
true
1
Sunny weather
string
collection
Devices
hardware
Response button
description
false
true
0
"A response button is an electrical component that can break an electrical circuit, interrupting the current or diverting it from one conductor to another. A switch is used by a tested subject as a control signal (response) for a stimulation system." 
http://en.wikipedia.org/wiki/Switch
string
hardware
Power supply
type
false
true
0
PS607110246wr
string
description
false
true
1
The component that supplies power to a amplifier. (http://www.webopedia.com/TERM/P/power_supply.html)
string
hardware
Reference electrode
type
false
true
0
E21-9S DISK ELECTRODE
string
description
false
true
1
A pure tin cup electrode with a 48" (122 cm) lead wire and a female socket. Device is used as a reference electrode, and is located at the root of the nose.
string
hardware
Small EEG cap
type
false
true
0
HEAD CIRCUMFERENCE: 50 - 54 cm
string
description
false
true
1
EEG cap captures the signal of neuronal activity in the brain from the head surface using electrode application technique.
string
hardware
Digital Portable - Real Hardware-mixer
title
false
true
0
Digital PortaStudio 564
string
type
false
true
1
PortaStudio564
string
description
false
true
2
Device is used for audio stimulation of tested subject within EEG stimulation protocol.
string
hardware
Ground electrode
title
false
true
0
E5-9S EAR ELECTRODE
string
description
false
true
1
A pair of pure tin cup electrodes with a 48" (122 cm) lead wire and a female socket. A spring-clip back, covered with plastic for patient comfort, is used to hold the electrode in place.Device is used as a ground electrode.
string
hardware
Amplifier
title
false
true
0
BRAIN AMP DC
string
type
false
true
1
AMP0711758DC
string
description
false
true
2
The BrainAmp DC includes all the outstanding features of the BrainAmp amplifier with the addition of the DC recording mode as well as with multiple hardware filtering options. The setup of the amplifier is fully controllable via the recording software.
string
hardware
USB 2 adapter
type
false
true
0
USB 2
string
description
false
true
1
Hardware device which provides an interface between an amplifier (optic fiber) and computer (USB2).
string
hardware
Headphones
type
false
true
0
Circumaural headphones
string
description
false
true
1
Device is used for audio stimulation of tested subject within EEG stimulation protocol.
string
hardware
Clinical audiometer
type
false
true
0
DA74
string
description
false
true
1
An audiometer is a machine used for evaluating hearing mechanism. (http://en.wikipedia.org/wiki/Audiometer)
string
hardware
ELECTRODE INPUT BOX 64 CHANNEL
type
false
true
0
EIB06031122
string
description
false
true
1
64-channel Electrode Input Box is a device that only allowed electrodes with single-input safety sockets to be connected to the BrainAmp recording amplifiers.
string
hardware
Sound-proof cabin
type
false
true
0
2x2x1,5m
string
description
false
true
1
Closable cabin formed by conducting material for one person (approx 2x2x1,5m) which muffle external noise. Cabin blocks external static and non-static electric fields by channeling electricity through conducting material and provides constant voltage on all sides of the cabin. Subject inside is screened out from events in the lab during the experiment. The cabin contains ventilation, light and window.
http://en.wikipedia.org/wiki/Faraday_cage
string
collection
Softwares
software
Presentation
description
false
true
0
Presentation is a stimulus delivery and experimental control program for neuroscience. Program delivers auditory, visual and multimodal stimuli with sub-millisecond temporal precision.
string
software
BrainVision Recorder 1.2
description
false
true
0
The BrainVision Recorder is used to control EEG amplifiers and record EEG signals.
string
collection
ProjectTypes
projectType
ProjectType
title
false
true
0
Grant Agency of the Czech Republic
string
description
false
true
1
This work was supported by the Grant Agency of the Czech Republic under the grant P407/12/1525.
string
collection
Experimentators
person
Person
surname
true
true
0
Vareka
string
givenname
true
true
1
Lukas
string
gender
true
true
2
M
string
person
Person1
surname
true
true
0
Mautner
string
givenname
true
true
1
Pavel
string
gender
true
true
2
M
string
person
Person2
surname
true
true
0
Bruha
string
givenname
true
true
1
Petr
string
gender
true
true
2
M
string
person
Person3
surname
true
true
0
Mouček
string
givenname
true
true
1
Roman
string
gender
true
true
2
M
string