2017-07-14
Information on the experimental setup
Location of the setup
Inst. de Neurosciences Cognitives de la Mediterranee (INCM), GLM, CNRS - Aix Marseille Univ., Marseille, Francestring
Location
Used data acquisition (DAQ) system
Cerebusstring
DAQSystem
Setup
Information on the experimental apparatus
Full name of person who created the setup
Thomas Brochierstring
Creator
Full name of person who maintains the setup
Thomas Brochierstring
Maintainer
Apparatus
Information on the input/output connector block
Type of apparatus
input/output connector blockstring
Type
Name of manufacturer used to build the experimental apparatus
NI, National Instruments Corporation, Austin, Texas, USAstring
Manufacturer
Function of apparatus
used to connect devices of the apparatus with the LabVIEW computer and the Neural Signal Processorstring
Function
NIConnectorBlock
setup
Information on the analog/digital converter card
Type of apparatus
NI 6023Estring
Type
Name of manufacturer used to build the experimental apparatus
NI, National Instruments Corporation, Austin, Texas, USAstring
Manufacturer
Function of apparatus
used as analog/digital converter for the LabVIEW computer, converts analog signal received from the table switch and send to control the reward pump to digital eventsstring
Function
ADConverterCard
setup
Information on the start switch
Function of apparatus
activates the internal initiation of the start trial event, its deactivation marks the onset of the reach-to-grasp movementstring
Function
Type of apparatus
table switchstring
Type
Signal type of apparatus (digital or analog)
analogstring
SignalType
Names of events extracted from this signal
SRstring
TrialEvents
Sampling rate of data
30000Hzint
SamplingRate
Target device of apparatus
NI connector blockstring
ConnectedTo
Control software of apparatus
LabVIEWstring
MonitoredBy
File in which apparatus signals are saved
nevstring
SavedIn
X position of apparatus relative to PosOrigin
5.0cmfloat
PosX
Y position of apparatus relative to PosOrigin
0.0cmfloat
PosY
Z position of apparatus relative to PosOrigin
0.0cmfloat
PosZ
Origin for x,y, and z position of apparatus
midline, waist-levelstring
PosOrigin
StartSwitch
setup
Information on the target object
Function of apparatus
object to grasp, pull and holdstring
Function
Type of apparatus
stainless steel parallelpipedstring
Type
Length of apparatus
40.0mmfloat
Length
Width of apparatus
16.0mmfloat
Width
Height of apparatus
10.0mmfloat
Height
Device apparatus is attached to
anterior end of a low- friction horizontal shuttlestring
AttachedTo
Rotation of apparatus from vertical axis
45.0degfloat
Rotation
X position of apparatus relative to PosOrigin
5.0cmfloat
PosX
Y position of apparatus relative to PosOrigin
13.0cmfloat
PosY
Z position of apparatus relative to PosOrigin
14.0cmfloat
PosZ
Origin for x,y, and z position of apparatus
midline, waist-levelstring
PosOrigin
Minimum and maximum pull range of target object
0.0mmfloat
15.0mmfloat
PullRange
Minimum and maximum weight range of target object
0.0gfloat
800.0gfloat
WeightRange
Mechanism to switch weight configuration
activation of magnetstring
WeightSwitch
Sensors providing additional analogue signals to monitor task and behavior
FSRSensorstring
HESensorstring
LoadForcestring
Sensors
TargetObject
Information on the FSR sensors
Function of apparatus
Measures grip and pulling load forces by means of force sensitive resistances (FSR)string
Function
Channel IDs of FSR sensors to measure load forces of side grip
138int
140int
SGChannelIDs
Channel IDs of FSR sensors to measure load forces of precision grip
137int
139int
PGChannelIDs
Signal type of apparatus (digital or analog)
analogstring
SignalType
Names of events extracted from this signal
OTstring
ORstring
TrialEvents
Sampling rate of data
1000Hzint
SamplingRate
Target device of apparatus
NeuralSignalProcessorstring
ConnectedTo
Control software of apparatus
LabVIEWstring
MonitoredBy
Preprocessing software used on signals of apparatus
MATLABstring
PreProcessedBy
Control software of apparatus
LabVIEWstring
ControlledBy
File in which apparatus signals are saved
ns2string
SavedIn
FSRSensor
setup/daq
Information on the hall-effect sensor
Function of apparatus
Hall effect (HE) sensor measures horizontal displacementstring
Function
Number of hall-effect sensors
1int
Count
Channel ID of HESensor to measure horizontal object displacement
143int
ChannelID
Names of events extracted from this signal
DOstring
OBBstring
TrialEvents
Signal type of apparatus (digital or analog)
analogstring
SignalType
File in which apparatus signals are saved
ns2string
SavedIn
HESensor
setup/daq
Information on the load force signal
Function of apparatus
used to detect load force of the target objectstring
Function
Number of load force signals
1int
Count
Channel ID of load force signal
141int
ChannelID
Signal type of apparatus (digital or analog)
analogstring
SignalType
File in which apparatus signals are saved
ns2string
SavedIn
LoadForce
setup/daq
setup
Information on the cue system
Function of apparatus
instructing movement configurations of each trialstring
Function
Type of apparatus
visual, LED cubestring
Type
Signal type of apparatus (digital or analog)
digitalstring
SignalType
Names of events extracted from this signal
WS-ONstring
CUE-ONstring
CUE-OFFstring
GO-ONstring
GO-OFFstring
ERROR-FLASH-ONstring
EventNames
Width of apparatus
10.0mmfloat
Width
Height of apparatus
10.0mmfloat
Height
X position of apparatus relative to PosOrigin
5.0cmfloat
PosX
Y position of apparatus relative to PosOrigin
13.0cmfloat
PosY
Z position of apparatus relative to PosOrigin
-1.0cmfloat
PosZ
Origin for x,y, and z position of apparatus
midline, waist-levelstring
PosOrigin
Number of LEDs
5int
LEDCount
Arrangement of LEDs
2-1-2string
LEDConfiguration
Color of the corner LEDs
redstring
CornerLEDColor
Color of the center LEDs
yellowstring
CenterLEDColor
Sampling rate of data
30000Hzint
SamplingRate
Target device of apparatus
NI connector blockstring
ConnectedTo
Control software of apparatus
LabVIEWstring
MonitoredBy
Control software of apparatus
LabVIEWstring
ControlledBy
File in which apparatus signals are saved
nevstring
SavedIn
CueSystem
Information on cue codes
LEDs coding this trial instruction
side gripstring
LeftLEDs
LEDs coding this trial instruction
precision gripstring
RightLEDs
LEDs coding this trial instruction
low forcestring
BottomLEDs
LEDs coding this trial instruction
high forcestring
TopLEDs
LEDs coding this trial instruction
fixation pointstring
CenterLED
LEDs coding this trial instruction
ERROR-FLASH-ONstring
FourCornerLEDs
LEDs coding this trial instruction
ERROR-FLASH-ONstring
ThreeCornerLEDs
CueCodes
setup/daq
setup
Information on the reward system
Function of apparatus
rewards subject if trial was performed correctlystring
Function
Type of apparatus
reward pipestring
Type
Signal type of apparatus (digital or analog)
digitalstring
SignalType
Names of events extracted from this signal
RW-ONstring
EventNames
Food used for reward
apple saucestring
RewardFood
Food amount used for reward per trial
0.5ml/200msfloat
RewardAmount
Sampling rate of data
30000Hzint
SamplingRate
Target device of apparatus
NeuralSignalProcessorstring
ConnectedTo
Control software of apparatus
LabVIEWstring
MonitoredBy
Control software of apparatus
LabVIEWstring
ControlledBy
File in which apparatus signals are saved
nevstring
SavedIn
RewardSystem
setup
setup
setup
Information on the experimental subject (animal or person) under investigation
Binomial species name (genus, species within genus)
Macaca mulattastring
Species
Commonly used (trivial) species name
Rhesus monkeystring
TrivialName
Given name
monkey_Lstring
GivenName
Short identifier for monkey (e.g., used in file names)
lstring
Identifier
Gender (male or female)
femalestring
Gender
Date of birth
2004-03-19date
Birthday
Trained hand (left and/or right)
leftstring
ActiveHand
Comment on existing disabilities
Middle phalanx of right thumb is missing.text
Disabilities
Comment on the general character/personality
Eager to work, quick and efficient but very nervous. Does not like to be touched (for instance for RF testing).text
Character
Subject
Information on the training given to subject
Full name(s) of person(s) responsible for the training
Thomas Brochierstring
Coach
Start date of training
2010-06-01date
Start
End date of training
2010-09-01date
End
Comment on training
Training was easy and fast, chair and hand training started together.string
Comment
Training
subject/preparation
Information on the array implant performed on subject
Date of the surgery
2010-09-15date
Date
Full name(s) of the person(s) responsible for the surgery
Ivan Balansardstring
Alexa Riehlestring
Surgeon
Hemisphere (left and/or right) in which surgery was performed
rightstring
Hemisphere
Rotation of the array in the CCW direction, where 0 degrees is defined by projecting the array onto a sagittal view of the brain with the wire bundle extruding to the anterior direction.
216.0degfloat
ArrayRotation
Comment on the surgery
no commentstring
Comment
ArrayImplant
subject/preparation
subject
Information on the experimental project
Name of project
reach-to-graspstring
Name
Type of project
electrophysiologystring
Type
Name of the project
motor behaviorstring
Subtype
Affiliations of the involved collaborators
Inst. of Neuroscience and Medicine (INM-6) and Inst. for Advanced Simulation (IAS-6), Juelich Research Centre & JARA, Juelich, Germanystring
Inst. de Neurosciences de la Timone (INT), UMR 7289, CNRS - Aix Marseille Univ., Marseille, Francestring
Collaborators
Project
Information on tasks
Names of possible task designs
OneCuestring
TwoCuesstring
Observationstring
Sleepstring
Mappingstring
PossibleDesigns
Name of the used task design
TwoCuesstring
UsedDesign
TaskDesigns
project
Information on condition codes (trial type combination codes)
Grip first trials, all grip and force types
SGLFstring
SGHFstring
PGLFstring
PGHFstring
cnd_1
Force first trials, all force and grip types
LFSGstring
HFSGstring
LFPGstring
HFPGstring
cnd_2
Grip first trials, all grip types, but only low force
SGLFstring
PGLFstring
cnd_11
Grip first trials, all grip types, but only high force
SGHFstring
PGHFstring
cnd_12
Grip first trials, only side grip, but all force types
SGHFstring
SGLFstring
cnd_13
Grip first trials, only precision grip, but all force types
PGHFstring
PGLFstring
cnd_14
Force first trials, only low force, but all grip types
LFSGstring
LFPGstring
cnd_21
Force first trials, only high force, but all grip types
HFSGstring
HFPGstring
cnd_22
Force first trials, all force types, but only side grip
HFSGstring
LFSGstring
cnd_23
Force first trials, all force types, but only side grip
HFPGstring
LFPGstring
cnd_24
Grip first trials, only side grip, only low force
SGLFstring
cnd_131
Grip first trials, only side grip, only high force
SGHFstring
cnd_132
Grip first trials, only side grip, force needs to be guessed
SGSGstring
cnd_133
Grip first trials, only precision grip, only low force
PGLFstring
cnd_141
Grip first trials, only precision grip, only high force
PGHFstring
cnd_142
Grip first trials, only precision grip, force needs to be guessed
PGPGstring
cnd_144
Force first trials, only low force, only side grip
LFSGstring
cnd_213
Force first trials, only low force, only precision grip
LFPGstring
cnd_214
Force first trials, only high force, only side grip
HFSGstring
cnd_223
Force first trials, only high force, only precision grip
HFPGstring
cnd_224
ConditionCodes
codes
Information on the trial sequence codes used to calculate performance codes
Decimal representation for 16-bit binary code, reflecting either the deactivation of TS or the end of a trial
TS-OFF/STOPstring
digev_65280
Decimal representation for 16-bit binary code, reflecting the activation of TS
TS-ONstring
digev_65296
Decimal representation for 16-bit binary code, reflecting the end of a trial
STOPstring
digev_65312
Decimal representation for 16-bit binary code, reflecting either the activation of WS or the deactivation of the first CUE
WS-ON/CUE-OFFstring
digev_65344
Decimal representation for 16-bit binary code, reflecting the activation of the LEDs coding PG (can be CUE-ON or GO-ON)
PG-ONstring
digev_65349
Decimal representation for 16-bit binary code, reflecting the activation of the LEDs coding HF (can be CUE-ON or GO-ON)
HF-ONstring
digev_65350
Decimal representation for 16-bit binary code, reflecting the activation of the LEDs coding LF (can be CUE-ON or GO-ON)
LF-ONstring
digev_65353
Decimal representation for 16-bit binary code, reflecting the activation of the LEDs coding SG (can be CUE-ON or GO-ON)
SG-ONstring
digev_65354
Decimal representation for 16-bit binary code, reflecting the activation of the LEDs coding the error feedback
ERROR-FLASH-ONstring
digev_65359
Decimal representation for 16-bit binary code, reflecting either the activation of WS or the deactivation of the first CUE
WS-ON/CUE-OFFstring
digev_65360
Decimal representation for 16-bit binary code, reflecting the activation of the LEDs coding PG (can be CUE-ON or GO-ON)
PG-ONstring
digev_65365
Decimal representation for 16-bit binary code, reflecting the activation of the LEDs coding HF (can be CUE-ON or GO-ON)
HF-ONstring
digev_65366
Decimal representation for 16-bit binary code, reflecting the activation of the LEDs coding LF (can be CUE-ON or GO-ON)
LF-ONstring
digev_65369
Decimal representation for 16-bit binary code, reflecting the activation of the LEDs coding SG (can be CUE-ON or GO-ON)
SG-ONstring
digev_65370
Decimal representation for 16-bit binary code, reflecting either the deactivation of GO LEDs or the deactivation of the RW pump
GO/RW-OFFstring
digev_65376
Decimal representation for 16-bit binary code, reflecting the activation of SR and the LEDs coding for PG
SR (+PG)string
digev_65381
Decimal representation for 16-bit binary code, reflecting the activation of SR and the LEDs coding for HF
SR (+HF)string
digev_65382
Decimal representation for 16-bit binary code, reflecting the activation of SR and the LEDs coding for PG and HF
SR (+PGHF/HFPG)string
digev_65383
Decimal representation for 16-bit binary code, reflecting the activation of SR and the LEDs coding for LF
SR (+LF)string
digev_65385
Decimal representation for 16-bit binary code, reflecting the activation of SR and the LEDs coding for SG
SR (+SG)string
digev_65386
Decimal representation for 16-bit binary code, reflecting the activation of SR and the LEDs coding for SG and LF
SR (+SGLF/LFSG)string
digev_65387
Decimal representation for 16-bit binary code, reflecting the activation of SR and the LEDs coding for PG and LF
SR (+PGLF/LFPG)string
digev_65389
Decimal representation for 16-bit binary code, reflecting the activation of SR and the LEDs coding for SG and HF
SR (+SGHF/HFSG)string
digev_65390
Decimal representation for 16-bit binary code, reflecting the activation of the LEDs coding the error feedback
ERROR-FLASH-ONstring
digev_65391
Decimal representation for 16-bit binary code, reflecting the activation of the RW pump with all LEDs turned off
RW-ON (noLEDs)string
digev_65440
Decimal representation for 16-bit binary code, reflecting the activation of the RW pump with central LED turned on
RW-ON (-CONF)string
digev_65504
Decimal representation for 16-bit binary code, reflecting the activation of the RW pump with LEDs coding for PG turned on
RW-ON (+CONF-PG)string
digev_65509
Decimal representation for 16-bit binary code, reflecting the activation of the RW pump with LEDs coding for HF turned on
RW-ON (+CONF-HF)string
digev_65510
Decimal representation for 16-bit binary code, reflecting the activation of the RW pump with LEDs coding for LF turned on
RW-ON (+CONF-LF)string
digev_65513
Decimal representation for 16-bit binary code, reflecting the activation of the RW pump with LEDs coding for SG turned on
RW-ON (+CONF-SG)string
digev_65514
DigitalEventLabelCodes
codes
Trial events used to control the trial sequence used to calculate the performance codes
Bit representation of trial event used for controlling the trial sequence and calculating the performance code
0int
TS-ON
Bit representation of trial event used for controlling the trial sequence and calculating the performance code
1int
WS-ON
Bit representation of trial event used for controlling the trial sequence and calculating the performance code
2int
CUE-ON
Bit representation of trial event used for controlling the trial sequence and calculating the performance code
3int
CUE-OFF
Bit representation of trial event used for controlling the trial sequence and calculating the performance code
4int
GO-ON
Bit representation of trial event used for controlling the trial sequence and calculating the performance code
5int
SR
Bit representation of trial event used for controlling the trial sequence and calculating the performance code
6int
RW-ON
Bit representation of trial event used for controlling the trial sequence and calculating the performance code
7int
STOP
TrialSequenceEvents
codes
Information on trial performance codes
Performance code of a correctly completed trial
correct_trialstring
perf_255
Performance code of a trial where the wrong grip type is used
grip_errorstring
perf_191
Performance code of a trial where an error occurs before the go is activated (GO-ON)
error<GO-ONstring
perf_175
Performance code of a trial where an error occurs before the cue is deactivated (CUE-OFF, with SR-ON)
error<CUE-OFFstring
perf_167
Performance code of a trial where an error occurs before the cue is activated (CUE-ON)
error<CUE-ONstring
perf_163
Performance code of a trial where an error occurs before the warning signal (WS) is activated
error<WSstring
perf_161
Performance code of a trial where an error occurs before the switch release is activated (SR-ON)
error<SR-ONstring
perf_159
Performance code of an incomplete trial sequence
incomplete_trialstring
perf_0
PerformanceCodes
codes
Information on the programmed trial settings
Possible digital recorded trial events
TS-ONstring
TS-OFFstring
WS-ONstring
CUE-ONstring
CUE-OFFstring
GO-ONstring
SRstring
SR-REPstring
RW-ONstring
RW-ON-REPstring
RW-OFFSTOPstring
ERROR-FLASH-ONstring
DigitalTrialEvents
Possible analog recorded trial events
OTstring
ORstring
DOstring
OBBstring
AnalogTrialEvents
Duration of trained holding time (period between online estimate of HS and RW)
500.0msfloat
HTTrained
Time limit for movement (period between SR and online estimate of HS)
700.0msfloat
MTLimit
Time limit for reaction time (period between GO-ON and SR)
700.0msfloat
RTLimit
TrialSettings
setup/control
Information on the settings of the target object
Distance window for holding the object in place
4mmint
14mmint
HoldPosRange
Weight of object in low force modus
100.0gfloat
LowForceWeight
Weight of object in high force modus
200.0gfloat
HighForceWeight
TargetObjectSettings
setup/control
project
Information on the Cerebus^TM data acquisition system
Owner of the device
RIKEN-BSI, Japanstring
Owner
Manufacturer of the device
Blackrock Microsystemsstring
Manufacturer
Cerebus
Information of the Cerebus^TM neural signal processor (NSP)
Type of the device
Real-timestring
Type
Model of the device
-string
Model
NeuralSignalProcessor
Information on external analog signals from or to the device
Connector port type
BNCstring
UsedPortType
AnalogSignals
Information on the analog-to-digital converter
Voltage range of analog input
-5.0Vfloat
5.0Vfloat
AIRange
Maximum impedance of analog input
100.0Ωfloat
MaxAIImpedance
Resolution of AD converter
0.15mV/bitfloat
Resolution
Width of digital data in bits
16bitint
DataBits
Sampling rate of data
1000samples/secint
SamplingRate
ADConverter
setup/daq
Information on analog input signals
Total number of input channels
16int
ChannelCount
Number of input channels used
6int
UsedChannelCount
Number of AC coupled input channels (IDs 1 - 9)
8int
ACChannelCount
Number of used AC coupled input channels
0int
UsedACChannelCount
Number of DC coupled input channels (IDs 9 -16)
8int
DCChannelCount
Number of used DC coupled input channels
8int
UsedDCChannelCount
Devices from which inputs are received
TargetObjectstring
InFrom
File in which input data are saved
ns2string
SavedIn
IDs of available channels from analog inputs
137int
138int
139int
140int
141int
143int
SavedChannelIDs
Input
setup/daq
Information on analog output signals
Total number of output channels
4int
ChannelCount
Number of output channels used
0int
UsedChannelCount
Target device of each output
-string
OutTo
File in which output data are saved
-string
SavedIn
Output
setup/daq
setup/daq
Information on behavioral signals of the device
File in which behavioral signals are saved
ns2string
SavedIn
BehavioralSignals
setup/daq
Information on neural signals of the device
Digital port type
Fiber-optic linkstring
UsedPortType
Total number of input channels
128int
ChannelCount
Number of input channels used
96int
UsedChannelCount
Devices from which inputs are received
NeuralSignalAmplifierstring
InFrom
File in which input data are saved
ns5string
SavedIn
IDs of available channels with neuronal data
1int
2int
3int
4int
5int
6int
7int
8int
9int
10int
11int
12int
13int
14int
15int
16int
17int
18int
19int
20int
21int
22int
23int
24int
25int
26int
27int
28int
29int
30int
31int
32int
33int
34int
35int
36int
37int
38int
39int
40int
41int
42int
43int
44int
45int
46int
47int
48int
49int
50int
51int
52int
53int
54int
55int
56int
57int
58int
59int
60int
61int
62int
63int
64int
65int
66int
67int
68int
69int
70int
71int
72int
73int
74int
75int
76int
77int
78int
79int
80int
81int
82int
83int
84int
85int
86int
87int
88int
89int
90int
91int
92int
93int
94int
95int
96int
SavedChannelIDs
NeuralSignals
Information on the digital filter settings
Used filter type
butterworthstring
Type
States if the used filter is causal
Trueboolean
Causal
High pass frequency used
0.3Hzfloat
HighPassFreq
Low pass frequency used
7500.0Hzfloat
LowPassFreq
High pass order used
1int
HighPassOrder
Low pass order used
3int
LowPassOrder
Estimated shift between the filtered signal and the spike times. A positive number indicates the amount of time the filtered signal is lagging behind.
0.0msfloat
EstimatedShift
Filter_ns5
setup/daq
setup/daq
Information on digital signals from and to the device
Possible digital input and output (DIO) types
ExpDigitalInputstring
ExpDigitalOutputstring
SerialDigitalInputstring
SerialDigitalOutputstring
ExtSyncstring
NSPSyncstring
Types
Used digital input and output (DIO) types
ExpDigitalInputstring
UsedTypes
DigitalSignals
Information on the experimental digital inputs
Connector port type
DB-37string
PortType
Total number of input channels
1int
ChannelCount
Number of used input channels usded
1int
UsedChannelCount
Width of digital data in bits
16bitint
DataBits
Sampling rate of data
30000samples/secint
SamplingRate
Devices from which inputs are received
-string
InFrom
File in which data are saved
nevstring
SavedIn
ExpDigitalInput
setup/daq/hardware
setup/daq
Information on spike detection
Used method to define a data threshold for the spike detection
user defined threshold crossingstring
ThresholdType
File in which input data are saved
nevstring
SavedIn
SpikeDetection
Information on the filter settings
Used filter type
butterworthstring
Type
States if the used filter is causal
Trueboolean
Causal
High pass frequency used
250.0Hzfloat
HighPassFreq
Low pass frequency used
7500.0Hzfloat
LowPassFreq
High pass order used
4int
HighPassOrder
Low pass order used
3int
LowPassOrder
Filter
setup/daq
Information on the recorded spike waveforms of the spike detection
Waveform window width
1.6msfloat
Width
Sampling rate of data
30000.0Hzfloat
SamplingRate
Number of samples before waveform passes threshold
10samplesint
PreThresholdSamples
Waveforms
setup/daq
Information on the recorded spike events of the spike detection
Sampling rate of data
30000samples/secint
SamplingRate
Range of possible unit IDs of online sorted spike events on each channel
1int
16int
PreSortedUnitIDRange
Unit ID of unclassified spike events on each channel
0int
UnclassifiedUnitID
Events
setup/daq
Information on rejected recorded spike events of the spike detection
Amplitude limits of spike waveforms used to reject spike events
-1.0mVfloat
AmplitudeLimits
Minimum number of channels with a synchronously detected spike events used to reject these spike events
-1int
SyncChannelLimit
Number of samples for which spike detection is turned off after a rejected synchronous spike event
-1.0samplesfloat
SyncChannelRefPeriod
Unit ID reserved for rejected spike events on each channel
255int
UnitID
Rejections
setup/daq
setup/daq
setup/daq/hardware
Information on the Cerebus^TM neural signal amplifier (NSA)
Type of amplifier
Front-End Amplifierstring
Type
Model of amplifier
-string
Model
Total number of analog input channels
128int
ChannelCount
Number of analog input channels used
96int
UsedChannelCount
File in which data would be saved (if it is saved)
ns6string
SavedIn
States if signal is saved without further processing
Falseboolean
IsSaved
NeuralSignalAmplifier
Information on the analog-to-digital converter
Voltage range of analog input
-8.192mVfloat
8.192mVfloat
AIRange
Resolution of AD converter
0.25µV/bitfloat
Resolution
Width of digital data in bits
16bitint
DataBits
ADConverter
setup/daq
Information on the analog filter settings of the amplifier
Filter type used
butterworthstring
Type
States if the used filter is causal
Trueboolean
Causal
High pass frequency used
0.3Hzfloat
HighPassFreq
Low pass frequency used
7.5kHzfloat
LowPassFreq
High pass order used
1int
HighPassOrder
Low pass order used
3int
LowPassOrder
Filter
setup/daq
Information on the amplifier
Gain used
5000int
Gain
Amplifier
setup/daq
setup/daq/hardware
Information on the Cerebus^TM control computer
ControlComputer
Information on the control software of the Cerebus^TM system
Name of software
CentralSuitestring
Name
Manufacturer of software
Blackrock Microsystemsstring
Manufacturer
ControlSoftware
setup/daq
setup/daq/software
setup/daq
Information on the Blackrock Utah Electrode Array
Owner of the device
RIKEN-BSI, Japanstring
Owner
Serial number of the device
1025-0503string
SerialNo
Manufacturer of the device
Blackrock Microsystemsstring
Manufacturer
Material of wires connecting array and connector
Pt/Austring
WiresMaterial
Diameter of each wire
25.0umfloat
WiresDiameter
Length of each wire
40.0mmfloat
WiresLength
UtahArray
Information on the used connector
Style of the connector
CerePortstring
Style
Height of the connector
16.5mmfloat
Height
Diameter of the base of the connector
19.0mmfloat
DiameterBase
Diameter of the body of the connector
11.0mmfloat
DiameterBody
Type of implantation
chronicstring
ImplantType
Type of mounting to the skull
bone screwsstring
SkullMount
Connector
setup/daq/hardware
Information on the used array
Number of array grids
1int
GridCount
Number of reference wires
2int
ReferenceCount
Number of ground wires
1int
GroundCount
Total number of electrodes
100int
ElectrodeCount
Number of connected/active electrodes
96int
ActiveElectrodeCount
Number of used/saved electrodes
96int
UsedElectrodeCount
Array
Information on array grid
Grid ID
1int
ID
Geometry of the electrode lengths
flatstring
ElectrodeGeometry
Electrode site metal option
iridium oxidestring
ElectrodeMetal
Inter-electrode-distance
400.0umfloat
ElectrodePitch
Insulation material
Parylene-Cstring
Insulation
Number of electrode rows
10int
GridRows
Number of electrode columns
10int
GridColumns
Width of array grid
4.0mmfloat
GridWidth
Length of array grid
4.0mmfloat
GridLength
Total number of electrodes
100int
ElectrodeCount
Number of connected/active electrodes
96int
ActiveElectrodeCount
Grid_01
setup/daq/hardware
Information on electrode
Electrode ID
1intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
1intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
91intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
52.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_001
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-18.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
2intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
2intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
92intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
44.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_002
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-17.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
3intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
3intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
94intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
50.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_003
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-41.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
8766int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
73.135523614mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
433.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.22460406731float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
4intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
4intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
1intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_004
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-31.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
5intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
5intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
75intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_005
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
3int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-47.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
17228int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
165.786278152mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
400.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
5.38343083203float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
22972int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
102.442190493mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
400.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.66535815799float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
6intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
6intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
96intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
46.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_006
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-36.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
9294int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
55.6401979772mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.89054981404float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
7intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
7intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
85intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
49.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_007
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-44.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
11738int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
111.83736582mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
200.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.73124053458float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
12756int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
73.1954374412mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
233.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.02161760461float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
8intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
8intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
97intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
47.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_008
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-30.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
9intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
9intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
86intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_009
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-39.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
10intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
10intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
98intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_010
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-57.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
7346int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
91.8309283964mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
233.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.03918992241float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
11intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
11intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
87intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
50.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_011
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-56.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
10570int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
122.267833491mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
166.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
5.55646307961float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
3449int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
98.0559582488mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.33659065345float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
12intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
12intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
88intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
50.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_012
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-35.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
13intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
13intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
77intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
41.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_013
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
3int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-45.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
8274int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
134.28208847mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
233.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
5.03112444625float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
9675int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
135.240723514mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
233.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
5.39951154758float
SNR
Unit_02
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
17131int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
82.8283229234mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.53206999221float
SNR
Unit_03
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
14intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
14intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
99intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
53.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_014
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
3int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-36.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
12097int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
82.8397123254mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.29998843406float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
11336int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
56.063161609mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.83665077249float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
15intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
15intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
66intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
46.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_015
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-46.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
16719int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
81.7292900293mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
300.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.7522721126float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
16intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
16intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
89intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_016
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-25.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
17intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
17intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
76intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
50.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_017
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-55.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
1187int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
96.2030328559mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
366.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.07281130089float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
18intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
18intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
100intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
55.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_018
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-27.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
19intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
19intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
67intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
52.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_019
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-49.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
2456int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
72.7019543974mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
366.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.63584165513float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
20intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
20intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
79intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
47.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_020
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-32.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
8392int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
93.9775977121mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
233.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.14392157826float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
21intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
21intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
58intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
55.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_021
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-24.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
22intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
22intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
10intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
57.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_022
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-32.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
19582int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
71.356143397mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
233.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.74504983353float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
23intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
23intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
78intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
45.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_023
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
3int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-41.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
7015int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
203.839344262mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
7.47688136061float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
8235int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
104.301760777mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
433.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.67151275375float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
24intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
24intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
70intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
53.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_024
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
3int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-34.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
23287int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
82.3195345042mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
433.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.9617322177float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
22092int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
63.6234383487mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
233.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.96736863599float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
25intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
25intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
68intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
47.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_025
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
3int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-47.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
4625int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
162.760216216mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
433.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
6.80682136131float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
8425int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
117.603323442mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
333.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
5.52815443259float
SNR
Unit_02
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
4168int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
75.3922744722mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
400.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.17835323606float
SNR
Unit_03
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
26intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
26intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
60intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
52.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_026
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-41.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
16624int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
74.3312078922mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
300.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.52683644914float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
27intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
27intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
69intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
46.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_027
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-63.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
3772int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
125.821580064mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
200.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
5.17280149944float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
28intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
28intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
50intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
53.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_028
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-59.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
13692int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
128.124087058mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
200.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
5.86277416682float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
29intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
29intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
59intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
52.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_029
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-58.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
30intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
30intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
40intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
51.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_030
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-31.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
31intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
31intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
49intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
49.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_031
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-46.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
3321int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
69.0611261668mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
433.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.83888764136float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
32intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
1intelectrodes_info.txt
BankID
Pin ID
32intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
30intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
49.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_032
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
3int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-38.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
6711int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
88.1758307257mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
333.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.30817904925float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
5823int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
58.8165893869mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
300.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.82686626272float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
33intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
1intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
83intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
44.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_033
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-36.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
9999int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
73.6539653965mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
366.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.08896963059float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
34intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
2intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
84intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
45.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_034
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
3int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-43.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
14330int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
125.075715283mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
500.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
5.69432771782float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
7256int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
75.5558158765mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
400.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.00132515458float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
35intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
3intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
73intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_035
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-52.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
36intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
4intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
74intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_036
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-49.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
22883int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
131.861556614mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
366.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.86906706819float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
37intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
5intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
63intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
47.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_037
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-34.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
5606int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
52.3810203354mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
466.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.9129035111float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
38intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
6intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
64intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
49.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_038
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-48.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
15125int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
115.016859504mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
133.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.63033671666float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
39intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
7intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
53intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
46.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_039
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
3int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-38.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
7973int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
230.038379531mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
200.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
9.26260611895float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
17228int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
119.100766195mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
5.56280725141float
SNR
Unit_02
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
12119int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
63.6652364056mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
300.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.99124805476float
SNR
Unit_03
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
40intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
8intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
54intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
43.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_040
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-35.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
41intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
9intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
43intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
45.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_041
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-41.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
14606int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
95.2685882514mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
200.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.12218539326float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
42intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
10intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
55intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_042
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-41.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
43intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
11intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
44intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
49.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_043
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-45.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
44intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
12intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
45intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
46.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_044
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-47.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
2710int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
77.8118081181mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.16708022668float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
45intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
13intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
33intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
45.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_045
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-52.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
8814int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
98.0965509417mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
333.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.51218475169float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
46intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
14intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
46intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_046
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-44.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
13395int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
92.0803284808mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.06037277795float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
47intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
15intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
34intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_047
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-53.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
48intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
16intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
65intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
45.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_048
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-61.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
10488int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
124.278508772mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
233.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
5.83275038874float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
4826int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
108.727103191mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.04882317633float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
49intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
17intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
24intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
52.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_049
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-37.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
50intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
18intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
56intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
43.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_050
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-25.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
51intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
19intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
35intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_051
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-72.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
1029int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
124.300291545mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
300.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.0145016405float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
52intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
20intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
47intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
49.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_052
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
3int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-57.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
8177int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
200.941421059mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
166.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
6.41161110738float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
18784int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
132.507293441mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
300.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.5555387579float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
53intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
21intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
25intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
44.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_053
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-27.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
54intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
22intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
57intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
43.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_054
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-42.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
8252int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
76.9680077557mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
233.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.27942627955float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
55intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
23intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
26intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_055
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-56.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
3703int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
90.0337564137mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
1.8333185493float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
56intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
24intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
36intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
51.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_056
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-57.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
19450int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
117.73496144mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
200.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.73497914782float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
10645int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
120.770502583mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
400.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.25307131817float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
57intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
25intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
27intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
90.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_057
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-56.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
58intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
26intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
37intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
51.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_058
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-66.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
59intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
27intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
28intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_059
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-56.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
60intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
28intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
38intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_060
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-49.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
7115int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
87.8313422347mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
300.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.93208007395float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
61intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
29intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
29intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
51.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_061
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
3int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-61.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
27368int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
142.29154487mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
366.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
6.06790027311float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
10107int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
113.26080934mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
300.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.4776258221float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
62intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
30intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
48intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
49.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_062
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-37.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
15909int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
60.7136840782mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.07398108782float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
63intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
31intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
19intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
50.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_063
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-42.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
5373int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
75.9316955146mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
466.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.39505185935float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
6130int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
55.6088091354mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
200.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.25066656103float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
64intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
32intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
39intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
47.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_064
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-45.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
13853int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
70.7360860463mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
333.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.72313614943float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
65intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
1intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
81intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
46.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_065
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-23.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
66intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
2intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
82intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_066
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-46.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
555int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
78.190990991mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
433.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.94031674863float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
67intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
3intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
71intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
47.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_067
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-27.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
68intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
4intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
72intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_068
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
3int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-44.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
20955int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
189.803817705mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
433.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
6.928430497float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
9534int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
81.399622404mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
400.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.86859475597float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
69intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
5intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
61intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
67.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_069
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-47.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
5901int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
78.7354685647mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
433.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.80307744754float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
70intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
6intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
62intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
52.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_070
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-41.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
11406int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
128.072944065mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
300.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
6.14789288669float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
9243int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
74.4520177432mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.63357895075float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
71intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
7intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
51intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
49.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_071
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
3int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-41.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
18015int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
139.919844574mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
333.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
6.13204346127float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
17452int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
81.1954503782mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
233.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.85887377912float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
72intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
8intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
52intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
45.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_072
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-30.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
73intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
9intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
41intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_073
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-31.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
74intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
2intelectrodes_info.txt
BankID
Pin ID
4intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
42intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
44.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_074
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-29.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
75intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
11intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
31intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
57.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_075
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-33.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
13759int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
122.282142598mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.48737131751float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
76intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
12intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
32intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
47.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_076
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-44.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
8932int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
132.026645768mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
233.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
5.65320446157float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
6411int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
66.7484011855mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
333.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.72578953268float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
77intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
13intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
21intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
46.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_077
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
3int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-43.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
3350int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
134.07761194mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
466.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.97251784558float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
12978int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
93.3302511943mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
400.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.80758806973float
SNR
Unit_02
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
15930int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
114.557438795mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
233.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.64440953369float
SNR
Unit_03
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
78intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
14intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
22intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_078
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-44.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
20818int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
82.7034777596mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
233.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.59002634607float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
10969int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
85.3457926885mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
366.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.28655764689float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
79intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
15intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
11intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
49.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_079
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-30.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
80intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
16intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
12intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
45.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_080
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
3int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-30.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
9977int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
143.532324346mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
366.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
6.28476477376float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
13374int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
106.175414984mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
333.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.69877490919float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
81intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
17intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
2intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
54.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_081
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-36.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
13787int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
62.4305505186mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
300.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.21581607896float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
82intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
18intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
23intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
48.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_082
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-39.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
12973int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
68.9084251908mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.32441115019float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
83intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
19intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
3intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
51.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_083
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-31.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
11378int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
49.6606609246mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
366.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.16811774909float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
84intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
20intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
13intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
49.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_084
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-72.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
23854int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
187.358933512mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
6.17252903156float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
85intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
21intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
4intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
49.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_085
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
2int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-49.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
6594int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
110.745526236mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
300.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.80498377751float
SNR
Unit_01
setup/daq
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
4473int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
90.2358596021mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
233.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.92105381368float
SNR
Unit_02
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
86intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
22intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
14intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
50.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_086
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-37.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
87intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
23intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
15intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
52.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_087
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-81.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
88intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
24intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
5intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
50.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_088
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
-1int
SUAIDs
IDs of multi unit activity
1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-40.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
89intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
25intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
16intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
50.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_089
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-46.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
2840int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
150.973239437mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
166.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.04761781055float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
90intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
26intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
6intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
49.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_090
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-40.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
9677int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
93.3732561744mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
300.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.96510362328float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
91intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
27intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
17intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
49.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_091
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-49.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
5913int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
84.0082868256mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
200.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.37949157372float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
92intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
28intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
7intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
51.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_092
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-37.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
11699int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
55.5672279682mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
366.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
2.64161756847float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
93intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
29intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
8intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
52.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_093
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
-1int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-51.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
12041int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
121.688314924mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
266.666666667usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
5.17476851988float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
94intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
30intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
18intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
53.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_094
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-51.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
11189int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
93.0406649388mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
233.333333333usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
4.39554303468float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
95intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
31intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
20intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
53.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_095
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-29.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
32894int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
69.5836018727mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
300.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.34727308195float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
Information on electrode
Electrode ID
96intelectrodes_info.txt
ID
Grid ID
1intelectrodes_info.txt
GridID
Bank ID
3intelectrodes_info.txt
BankID
Pin ID
32intelectrodes_info.txt
PinID
Connector aligned ID (array head view, wiring to connector on right side, count order from left to right and bottom to top)
9intelectrodes_info.txt
ConnectorAlignedID
Pre-implantation impedance
54.0kΩfloatelectrodes_info.txt
Impedance
Length
1.5mmfloat
Length
Electrode_096
Information on the spike sorting performed offline, after the experiment
IDs of single unit activity
1int
SUAIDs
IDs of multi unit activity
2int
MUAID
IDs for rejected units
0int
255int
NoiseIDs
Threshold used for spike detection
-40.0mVfloatl101210-001.nev
SpikeThreshold
OfflineSpikeSorting
Information on the waveforms of the corresponding unit
Number of extracted waveforms (spikes) for unit
8413int
SpikeCount
Measured averaged amplitude of spike waveforms for unit
80.6990372043mVfloat
SpikeAmplitude
Measured averaged duration of spike waveforms unit
400.0usfloat
SpikeDuration
Signal-to-noise ratio of unit waveforms, measured SNR value in analogy to Hatsopoulos N, Joshi J, O'Leary JG (2004) Decoding continuous and discrete motor behaviors using motor and premotor cortical ensembles. J Neurophysiol 92:1165-1174 and Suner S, Fellows MR, Vargas-Irwin C, Nakata GK, Donoghue JP (2005) Reliability of signals from a chronically ilplanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524-541.
3.39495275608float
SNR
Unit_01
setup/daq
setup/daq/preprocessing
setup/daq/hardware
setup/daq/hardware
setup/daq/hardware
Information on the headstage
Model of device
Samtecstring
Model
Type of device (digital or analog)
analogstring
Type
Gain used
1int
Gain
Devices from which inputs are received
UtahArraystring
InFrom
Target device of each output
NeuralSignalAmplifierstring
OutTo
True if a stimulation switch version of the device was used
Trueboolean
StimSwitch
Headstage
setup/daq/hardware
Information on the recording
Identifier of the recording day
l101210string
RecordingDay
Identifier of the recording
l101210-001string
Recording
Date of session
2010-12-10date
Date
Weekday of session
Fridaystring
Weekday
Time of day when recording was started
10:50:10time
Time
Duration of recording
709.248sint
Duration
States if a spike sorting was performed for this recording
Trueboolean
IsSpikeSorted
Performed task type
TwoCuesstring
TaskType
Qualitative statement whether the recording contains noisy channels and/or time periods.
Trueboolean
Noisy
Comment about the recording
no commentstring
Comment
Recording
Information on task settings
Total number of trials
204int
TotalTrialCount
Number of correctly performed trials
135int
CorrectTrialCount
Number of trials where the monkey made a grip error.
14int
GripErrorTrialCount
States if the recording was performed under standard settings
Trueboolean
StandardSettings
TaskSettings
Information on trial type parameters
Identifies the trial types presented during the recording
1int
Condition
Trial order of force conditions (random or block)
randomstring
OrderForce
Trial order of grip conditions (random or block)
randomstring
OrderGrip
Order of trial type combination was of block size
-1int
BlockSize
TrialTypeSettings
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
1intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
41551./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
191intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_001
Information on digital trial events
Time when trial start event is internally activated.
41551./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
48141./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
162641./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
283061./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
374421./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
675241./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
732801./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
1196201./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121091./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120421./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91361./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300821./30000*sint
DELAY
Reaction time (period between GO and SR)
57561./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
2intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
1197691./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_002
Information on digital trial events
Time when trial start event is internally activated.
1197691./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
1203591./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
1318081./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
1438831./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
1529911./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
1830641./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
1891031./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
2124371./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
2124411./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
2365971./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
1928701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
2216701./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
1959301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
2190601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
1938601./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
2229601./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
1984201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
2203201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120391./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91081./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300731./30000*sint
DELAY
Reaction time (period between GO and SR)
60391./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
37671./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
30601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
68271./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
231301./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
219001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1521./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
3intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
2367491./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_003
Information on digital trial events
Time when trial start event is internally activated.
2367491./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
2376921./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
2491191./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
2611931./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
2703871./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
3004861./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
3036851./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
3288891./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
3288911./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
3525641./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
3079801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
3366001./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
3098401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
3346201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
3087601./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
3362401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
3182401./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
3312601./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
123701./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91941./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300991./30000*sint
DELAY
Reaction time (period between GO and SR)
31991./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
42951./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
18601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
61551./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
247801./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
130201./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
4intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
3527151./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_004
Information on digital trial events
Time when trial start event is internally activated.
3527151./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
3532971./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
3647701./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
3768171./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
3858971./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
4159711./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
4216511./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
4440581./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
4440611./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
4676191./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
4246501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
4529701./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
4275601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
4485901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
4263901./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
4536601./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
4330801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
4511701./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120551./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120471./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90801./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
56801./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
29991./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
29101./30000*sint
PT
Movement time (period between SR and HEplat-ON)
59091./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
210301./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
180901./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
5intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
4677691./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_005
Information on digital trial events
Time when trial start event is internally activated.
4677691./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
4683701./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
4798591./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
4919001./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
5009801./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
5310541./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
5361941./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
5616501./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
5616521./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
5852691./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
5392801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
5708101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
5421301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
5655901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
5415001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
5709901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
5525101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
5680501./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120901./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120411./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90801./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
51401./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
30861./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
28501./30000*sint
PT
Movement time (period between SR and HEplat-ON)
59361./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
234601./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
155401./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1031./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
6intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
5853721./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
167intl101210-001.nev
PerformanceCode
Trial type of trial
SGstringl101210-001.nev
TrialType
Trial_006
Information on digital trial events
Time when trial start event is internally activated.
5853721./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
5860261./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
5974531./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
6094951./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
6714641./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
6114121./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120811./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120421./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
7intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
6716141./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
167intl101210-001.nev
PerformanceCode
Trial type of trial
PGstringl101210-001.nev
TrialType
Trial_007
Information on digital trial events
Time when trial start event is internally activated.
6716141./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
6722161./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
6836491./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
6958291./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
7043021./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
-11./30000*sint
STOP
Time when error flash was shown as negative feedback in response to an error trial
7299251./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120351./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
121801./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
7506131./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
8intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
7506121./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_008
Information on digital trial events
Time when trial start event is internally activated.
7506121./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
7511971./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
7626501./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
7747241./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
7837971./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
8138711./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
8209641./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
8437741./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
8437791./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
8674761./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
8246101./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
8499301./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
8263201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
8427601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
8256901./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
8505901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
8321101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
8457901./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120381./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
70931./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
36461./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
17101./30000*sint
PT
Movement time (period between SR and HEplat-ON)
53561./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
164401./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
136801./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1411./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
9intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
8676171./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_009
Information on digital trial events
Time when trial start event is internally activated.
8676171./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
8682661./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
9373771./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
8778921./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1451./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
10intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
9375221./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_010
Information on digital trial events
Time when trial start event is internally activated.
9375221./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
9381671./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
9496201./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
9616941./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
9707671./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
10008081./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
10036471./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
10264361./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
10264401./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
10501081./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
10068601./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
10341901./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
10102201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
10281301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
10081801./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
10335301./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
10143901./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
10283401./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120981./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300411./30000*sint
DELAY
Reaction time (period between GO and SR)
28391./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
32131./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
33601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
65731./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
179101./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
139501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
11intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
10502591./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_011
Information on digital trial events
Time when trial start event is internally activated.
10502591./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
10508681./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
10623111./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
10743851./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
10834251./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
11135051./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
11197171./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
11420691./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
11420731./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
11657841./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
11228401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
11500201./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
11244001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
11443501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
11241001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
11479801./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
11301001./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
11344501./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120521./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90401./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300801./30000*sint
DELAY
Reaction time (period between GO and SR)
62121./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
31231./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
15601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
46831./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
199501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
43501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
12intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
11659341./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_012
Information on digital trial events
Time when trial start event is internally activated.
11659341./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
11670321./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
11784591./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
11905351./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
11996321./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
12297061./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
12337991./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
12577901./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
12577921./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
12814401./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
12378001./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
12656101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
12416101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
12531901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
12405001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
12657301./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
12454501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
12594901./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
125251./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120761./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90971./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
40931./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
40011./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
38101./30000*sint
PT
Movement time (period between SR and HEplat-ON)
78111./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
115801./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
140401./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
13intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
12815901./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_013
Information on digital trial events
Time when trial start event is internally activated.
12815901./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
12821661./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
12935931./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
13056681./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
13147671./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
13448411./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
13483611./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
13718711./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
13809181./30000*sintl101210-001.nev
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
13954341./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
13526101./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
13802701./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
13555201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
13765201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
13540801./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
13797601./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
13593301./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
13749301./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120031./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90991./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
35201./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
42491./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
29101./30000*sint
PT
Movement time (period between SR and HEplat-ON)
71591./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
210001./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
156001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1611./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
14intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
13955951./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_014
Information on digital trial events
Time when trial start event is internally activated.
13955951./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
13961851./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
14681461./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
14080101./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
15intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
14682961./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_015
Information on digital trial events
Time when trial start event is internally activated.
14682961./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
14689291./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
15334391./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
14739271./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
4811./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
16intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
15339201./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_016
Information on digital trial events
Time when trial start event is internally activated.
15339201./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
15344951./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
15459221./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
15579961./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
15670701./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
15971441./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
16024961./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
16248451./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
16248471./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
16485061./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
16053601./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
16304401./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
16084201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
16199401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
16066501./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
16328701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
16120501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
16247401./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120021./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90741./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
53521./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
28641./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
30601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
59241./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
115201./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
126901./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2171./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
17intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
16487231./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_017
Information on digital trial events
Time when trial start event is internally activated.
16487231./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
16493051./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
16607421./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
16728411./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
16819141./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
17119931./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
17161411./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
17391621./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
17391641./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
17627271./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
17198401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
17486101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
17219701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
17232901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
17211601./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
17464201./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
17271301./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
17402401./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120191./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120991./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300791./30000*sint
DELAY
Reaction time (period between GO and SR)
41481./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
36991./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
21301./30000*sint
PT
Movement time (period between SR and HEplat-ON)
58291./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
13201./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
131101./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
18intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
17628761./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_018
Information on digital trial events
Time when trial start event is internally activated.
17628761./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
17634801./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
17749531./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
17870001./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
17960801./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
18261541./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
18313271./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
18455651./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
18455671./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
18471151./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
18616351./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
18349501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
18580201./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
18372601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
18549001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
18372001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
18539701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
18414301./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
18420001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120771./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120471./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90801./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
51731./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
36231./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
23101./30000*sint
PT
Movement time (period between SR and HEplat-ON)
59331./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
176401./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
5701./30000*sint
HEplat
Inter-trial-interval (period until next trial)
25841./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
19intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
18642191./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_019
Information on digital trial events
Time when trial start event is internally activated.
18642191./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
18649001./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
18763761./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
18884251./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
18975051./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
19277071./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
19342001./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
19612261./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
19612301./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
19848471./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
19381201./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
19655101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
19395301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
19630201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
19404301./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
19647901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
19458301./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
19588801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121571./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120491./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90801./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
302021./30000*sint
DELAY
Reaction time (period between GO and SR)
64931./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
39201./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
14101./30000*sint
PT
Movement time (period between SR and HEplat-ON)
53301./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
234901./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
130501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1261./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
20intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
19849731./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_020
Information on digital trial events
Time when trial start event is internally activated.
19849731./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
19855731./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
19970191./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
20091001./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
20181741./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
20482481./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
20558221./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
20794371./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
20794411./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
21031231./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
20596801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
20884501./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
20608801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
20852701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
20615101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
20895001./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
20664601./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
20854801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120461./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90741./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
75741./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
38581./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
12001./30000*sint
PT
Movement time (period between SR and HEplat-ON)
50581./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
243901./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
190201./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
21intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
21032731./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
191intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_021
Information on digital trial events
Time when trial start event is internally activated.
21032731./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
21043431./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
21157681./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
21278421./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
21369401./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
21670141./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
21723671./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
22005791./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
124951./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90981./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
53531./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
102281./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
22intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
22108071./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_022
Information on digital trial events
Time when trial start event is internally activated.
22108071./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
22114471./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
22228951./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
22350621./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
22441361./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
22742101./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
22865501./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
23096181./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
23096231./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
23265841./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
22907101./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
23165101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
22941601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
23143501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
22977901./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
23116501./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
23028301./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
23055601./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120881./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
121671./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90741./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
123401./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
41601./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
34501./30000*sint
PT
Movement time (period between SR and HEplat-ON)
76101./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
201901./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
27301./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1621./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
23intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
23267461./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_023
Information on digital trial events
Time when trial start event is internally activated.
23267461./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
23273441./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
23387991./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
23508461./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
23598921./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
23899751./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
23955941./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
24230891./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
24230921./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
24321311./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
24466521./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
23992201./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
24277201./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
24012301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
24240301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
24001801./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
24279301./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
24084301./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
24254401./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120531./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120471./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90461./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300831./30000*sint
DELAY
Reaction time (period between GO and SR)
56191./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
36261./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
20101./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56361./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
228001./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
170101./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1521./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
24intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
24468041./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_024
Information on digital trial events
Time when trial start event is internally activated.
24468041./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
24483391./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
24597921./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
24718731./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
24809131./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
25109961./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
25156651./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
25391011./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
25391051./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
25626651./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
25187401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
25466101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
25204801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
25423801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
25206301./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
25477201./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
25275001./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
25430101./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
129881./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90401./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300831./30000*sint
DELAY
Reaction time (period between GO and SR)
46691./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
30751./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
17401./30000*sint
PT
Movement time (period between SR and HEplat-ON)
48151./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
219001./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
155101./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
25intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
25628141./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_025
Information on digital trial events
Time when trial start event is internally activated.
25628141./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
25634151./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
25748511./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
25869241./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
25959641./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
26260451./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
26316371./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
26560491./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
26797371./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
26351701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
26635501./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
26373301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
26604901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
26370001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
26632501./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
26435401./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
26569201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120371./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120731./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90401./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
55921./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
35331./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
21601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56931./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
231601./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
133801./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2201./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
26intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
26799571./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_026
Information on digital trial events
Time when trial start event is internally activated.
26799571./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
26805691./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
26920171./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
27040911./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
27131641./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
27432051./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
27483841./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
27759601./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
27995231./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
27520501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
27836101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
27553201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
27816601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
27546301./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
27842401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
27647101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
27780001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120601./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300411./30000*sint
DELAY
Reaction time (period between GO and SR)
51791./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
36661./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
32701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
69361./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
263401./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
132901./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
27intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
27996741./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_027
Information on digital trial events
Time when trial start event is internally activated.
27996741./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
28007151./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
28121681./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
28243171./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
28333561./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
28634381./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
28679401./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
28914201./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
28914221./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
29160561./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
28711801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
29015701./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
28735801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
28972201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
28727401./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
29025001./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
28794301./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
28998601./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
124941./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
121491./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90391./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300821./30000*sint
DELAY
Reaction time (period between GO and SR)
45021./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
32401./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
24001./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56401./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
236401./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
204301./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
28intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
29162061./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_028
Information on digital trial events
Time when trial start event is internally activated.
29162061./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
29172581./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
29287121./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
29407941./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
29498871./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
29799611./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
29868411./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
30094521./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
30094561./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
30331431./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
29900701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
30177301./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
29917801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
30139501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
29912401./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
30176701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
29975701./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
30068101./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
125061./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120821./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90931./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
68801./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
32291./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
17101./30000*sint
PT
Movement time (period between SR and HEplat-ON)
49391./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
221701./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
92401./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1481./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
29intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
30332911./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_029
Information on digital trial events
Time when trial start event is internally activated.
30332911./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
30347651./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
30462201./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
30583001./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
30673401./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
30974221./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
31019371./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
31263731./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
31263771./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
31503041./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
31059301./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
31348801./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
31072801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
31317901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
31070701./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
31365901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
31156501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
31334101./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
129291./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120801./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90401./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300821./30000*sint
DELAY
Reaction time (period between GO and SR)
45151./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
39931./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
13501./30000*sint
PT
Movement time (period between SR and HEplat-ON)
53431./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
245101./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
177601./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
30intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
31504531./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
167intl101210-001.nev
PerformanceCode
Trial type of trial
SGstringl101210-001.nev
TrialType
Trial_030
Information on digital trial events
Time when trial start event is internally activated.
31504531./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
31510431./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
31624981./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
31745801./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
32366441./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
31769561./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120451./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120821./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
31intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
32367951./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_031
Information on digital trial events
Time when trial start event is internally activated.
32367951./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
32375251./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
32489511./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
32610261./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
32701241./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
33001991./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
33055791./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
33282251./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
33282291./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
33372691./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
33522031./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
33086401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
33374401./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
33113101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
33337201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
33096601./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
33384601./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
33166501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
33351001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121561./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90981./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300751./30000*sint
DELAY
Reaction time (period between GO and SR)
53801./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
30611./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
26701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
57311./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
224101./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
184501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2271./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
32intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
33524301./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
191intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_032
Information on digital trial events
Time when trial start event is internally activated.
33524301./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
33530701./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
33645111./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
33765921./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
33856811./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
34157551./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
34208931./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
34496141./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120811./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90891./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
51381./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
87911./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
33intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
34584051./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
163intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_033
Information on digital trial events
Time when trial start event is internally activated.
34584051./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
34590041./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
34704601./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
35362811./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
34768051./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120551./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1231./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
34intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
35364041./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
167intl101210-001.nev
PerformanceCode
Trial type of trial
PGstringl101210-001.nev
TrialType
Trial_034
Information on digital trial events
Time when trial start event is internally activated.
35364041./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
35370221./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
35484491./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
35605241./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
35688431./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
-11./30000*sint
STOP
Time when error flash was shown as negative feedback in response to an error trial
35943801./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120451./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
36150981./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
35intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
36150971./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_035
Information on digital trial events
Time when trial start event is internally activated.
36150971./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
36157391./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
36795811./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
36200941./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1521./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
36intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
36797331./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_036
Information on digital trial events
Time when trial start event is internally activated.
36797331./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
36806611./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
36920891./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
37041641./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
37132371./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
37434401./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
37493941./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
37728861./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
37819341./30000*sintl101210-001.nev
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
37964521./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
37530901./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
37808701./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
37553101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
37600501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
37544101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
37822801./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
37625401./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
37758301./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
123561./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
302031./30000*sint
DELAY
Reaction time (period between GO and SR)
59541./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
36961./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
22201./30000*sint
PT
Movement time (period between SR and HEplat-ON)
59161./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
47401./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
132901./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1221./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
37intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
37965741./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
167intl101210-001.nev
PerformanceCode
Trial type of trial
PGstringl101210-001.nev
TrialType
Trial_037
Information on digital trial events
Time when trial start event is internally activated.
37965741./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
37972041./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
38086561./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
38207371./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
38866621./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
38271311./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120821./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1201./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
38intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
38867821./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_038
Information on digital trial events
Time when trial start event is internally activated.
38867821./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
38873771./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
38988041./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
39108791./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
39199791./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
39500531./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
39553741./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
39783741./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
40019391./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
39588901./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
39865501./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
39604201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
39826501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
39598501./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
39867901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
39667501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
39810301./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120221./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91001./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
53211./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
35161./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
15301./30000*sint
PT
Movement time (period between SR and HEplat-ON)
50461./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
222301./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
142801./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
39intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
40020901./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_039
Information on digital trial events
Time when trial start event is internally activated.
40020901./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
40036261./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
40150541./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
40271271./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
40362021./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
40662821./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
40713731./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
40955871./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
41046331./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
41191171./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
40750501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
41042101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
40767301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
41004001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
40766701./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
41054401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
40849501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
41022001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
129641./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120731./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90751./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300801./30000*sint
DELAY
Reaction time (period between GO and SR)
50911./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
36771./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
16801./30000*sint
PT
Movement time (period between SR and HEplat-ON)
53571./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
236701./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
172501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
40intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
41192661./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_040
Information on digital trial events
Time when trial start event is internally activated.
41192661./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
41198441./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
41312791./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
41433531./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
41523931./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
41824731./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
41871331./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
42042571./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
42042611./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
42209551./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
41904601./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
42162601./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
41928301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
42134401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
41919601./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
42140401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
41979901./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
42107101./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120131./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90401./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300801./30000*sint
DELAY
Reaction time (period between GO and SR)
46601./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
33271./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
23701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56971./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
206101./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
127201./30000*sint
HEplat
Inter-trial-interval (period until next trial)
13161./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
41intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
42222711./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_041
Information on digital trial events
Time when trial start event is internally activated.
42222711./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
42228471./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
42343041./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
42463531./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
42553991./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
42854801./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
42908601./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
43141371./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
43377951./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
42943501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
43215001./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
42970201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
43190401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
42954001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
43217701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
43018201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
43170601./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120331./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120491./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90461./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
53801./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
34901./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
26701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
61601./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
220201./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
152401./30000*sint
HEplat
Inter-trial-interval (period until next trial)
8751./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
42intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
43386701./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_042
Information on digital trial events
Time when trial start event is internally activated.
43386701./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
43393041./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
43507511./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
43628031./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
43718831./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
44019561./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
44063761./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
44312951./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
44548581./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
44097001./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
44396401./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
44117101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
44359801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
44116501./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
44408401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
44215801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
44383801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120811./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120521./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90801./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300731./30000*sint
DELAY
Reaction time (period between GO and SR)
44201./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
33241./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
20101./30000*sint
PT
Movement time (period between SR and HEplat-ON)
53341./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
242701./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
168001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
43intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
44550071./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
191intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_043
Information on digital trial events
Time when trial start event is internally activated.
44550071./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
44556431./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
44670951./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
44791421./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
44882221./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
45182961./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
45241101./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
45527871./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120881./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120471./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90801./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
58141./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
144571./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
44intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
45672441./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
175intl101210-001.nev
PerformanceCode
Trial type of trial
SGstringl101210-001.nev
TrialType
Trial_044
Information on digital trial events
Time when trial start event is internally activated.
45672441./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
45678441./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
45793001./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
45913471./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
46003941./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
46707551./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
46111901./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120561./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120471./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90471./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1131./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
45intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
46708681./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_045
Information on digital trial events
Time when trial start event is internally activated.
46708681./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
46714651./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
46829141./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
46949871./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
47040601./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
47341011./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
47398811./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
47621081./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
47621101./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
47858201./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
47427601./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
47708401./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
47452501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
47684701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
47442601./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
47719801./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
47539201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
47681701./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120461./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120731./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300411./30000*sint
DELAY
Reaction time (period between GO and SR)
57801./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
28791./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
24901./30000*sint
PT
Movement time (period between SR and HEplat-ON)
53691./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
232201./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
142501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
46intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
47859701./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_046
Information on digital trial events
Time when trial start event is internally activated.
47859701./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
47865721./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
47980481./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
48100951./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
48191761./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
48492541./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
48535271./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
48726091./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
48726111./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
48753561./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
48898751./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
48570001./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
48829201./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
48591301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
48794101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
48575701./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
48825001./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
48640501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
48721501./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120781./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120471./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90811./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300781./30000*sint
DELAY
Reaction time (period between GO and SR)
42731./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
34731./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
21301./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56031./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
202801./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
81001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
6571./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
47intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
48905321./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_047
Information on digital trial events
Time when trial start event is internally activated.
48905321./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
48915991./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
49030531./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
49151001./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
49241471./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
49542541./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
49600331./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
49838221./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
49838241./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
50075111./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
49636201./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
49911001./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
49649401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
49655101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
49648501./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
49920301./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
49738201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
49896001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
125211./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120471./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90471./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
301071./30000*sint
DELAY
Reaction time (period between GO and SR)
57791./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
35871./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
13201./30000*sint
PT
Movement time (period between SR and HEplat-ON)
49071./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
5701./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
157801./30000*sint
HEplat
Inter-trial-interval (period until next trial)
3371./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
48intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
50078481./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_048
Information on digital trial events
Time when trial start event is internally activated.
50078481./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
50091071./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
50205821./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
50326301./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
50417091./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
50717831./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
50757561./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
51000731./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
51000781./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
51236381./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
50795401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
51084901./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
50816701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
51046201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
50805001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
51084001./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
50879401./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
51043501./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
127341./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120481./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90791./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
39731./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
37841./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
21301./30000*sint
PT
Movement time (period between SR and HEplat-ON)
59141./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
229501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
164101./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
49intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
51237881./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_049
Information on digital trial events
Time when trial start event is internally activated.
51237881./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
51249751./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
51364311./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
51485111./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
51575511./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
51876321./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
51917341./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
52178731./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
52414371./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
51953701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
52225501./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
51973801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
52192801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
51970501./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
52239601./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
52071601./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
52210801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
126431./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120801./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90401./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
41021./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
36361./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
20101./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56461./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
219001./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
139201./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2101./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
50intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
52416471./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
191intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_050
Information on digital trial events
Time when trial start event is internally activated.
52416471./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
52422731./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
52537531./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
52658341./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
52749071./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
53049811./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
53711331./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
53106421./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121061./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
-53049821./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1281./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
51intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
53712611./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_051
Information on digital trial events
Time when trial start event is internally activated.
53712611./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
53719141./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
54335821./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
53740981./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1461./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
52intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
54337281./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_052
Information on digital trial events
Time when trial start event is internally activated.
54337281./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
54343741./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
54458171./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
54578931./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
54669651./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
54970561./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
55029761./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
55258351./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
55258401./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
55348821./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
55494031./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
55062601./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
55324201./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
55089301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
55309801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
55073101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
55334401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
55130101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
55291201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120891./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120761./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90721./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300911./30000*sint
DELAY
Reaction time (period between GO and SR)
59201./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
32841./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
26701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
59541./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
220501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
161101./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
53intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
55495541./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_053
Information on digital trial events
Time when trial start event is internally activated.
55495541./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
55501511./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
55616181./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
55736601./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
55827061./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
56127871./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
56181091./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
56415891./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
56415931./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
56656291./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
56210101./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
56507101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
56237701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
56374201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
56234401./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
56519401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
56302801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
56489401./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120641./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120421./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90461./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
53221./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
29011./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
27601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56611./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
136501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
186601./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1161./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
54intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
56657451./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_054
Information on digital trial events
Time when trial start event is internally activated.
56657451./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
56663421./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
57364131./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
56769351./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1481./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
55intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
57365611./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_055
Information on digital trial events
Time when trial start event is internally activated.
57365611./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
57371501./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
57486011./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
57606841./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
57697741./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
57998151./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
58036141./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
58253921./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
58253941./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
58489791./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
58064401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
58336501./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
58085401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
58308301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
58073101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
58337401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
58128601./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
58292701./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120401./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120831./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90901./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300411./30000*sint
DELAY
Reaction time (period between GO and SR)
37991./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
28261./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
21001./30000*sint
PT
Movement time (period between SR and HEplat-ON)
49261./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
222901./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
164101./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1331./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
56intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
58491121./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_056
Information on digital trial events
Time when trial start event is internally activated.
58491121./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
58497101./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
58611371./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
58732121./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
58822521./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
59123641./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
59186681./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
59416431./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
59651731./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
59213701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
59499901./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
59236201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
59453101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
59234101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
59501701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
59306101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
59442901./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120251./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90401./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
301121./30000*sint
DELAY
Reaction time (period between GO and SR)
63041./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
27021./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
22501./30000*sint
PT
Movement time (period between SR and HEplat-ON)
49521./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
216901./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
136801./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
57intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
59653241./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_057
Information on digital trial events
Time when trial start event is internally activated.
59653241./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
59658981./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
59773311./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
59894061./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
59984471./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
60285291./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
60319891./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
60554851./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
60554901./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
60791691./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
60364201./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
60643501./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
60386101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
60600001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
60377101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
60641701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
60428701./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
60587701./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120071./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90411./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300821./30000*sint
DELAY
Reaction time (period between GO and SR)
34601./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
44311./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
21901./30000*sint
PT
Movement time (period between SR and HEplat-ON)
66211./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
213901./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
159001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
58intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
60793191./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_058
Information on digital trial events
Time when trial start event is internally activated.
60793191./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
60799191./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
60913481./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
61035331./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
61126071./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
61426901./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
61465691./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
61701801./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
61701821./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
61938601./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
61506601./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
61776901./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
61534801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
61756801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
61517401./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
61794601./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
61586101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
61721701./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120291./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
121851./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90741./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300831./30000*sint
DELAY
Reaction time (period between GO and SR)
38791./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
40911./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
28201./30000*sint
PT
Movement time (period between SR and HEplat-ON)
69111./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
222001./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
135601./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
59intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
61940101./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_059
Information on digital trial events
Time when trial start event is internally activated.
61940101./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
61946461./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
62611141./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
62015751./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
60intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
62612651./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_060
Information on digital trial events
Time when trial start event is internally activated.
62612651./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
62619091./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
62733591./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
62854001./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
62944801./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
63245531./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
63290661./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
63519461./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
63519511./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
63762721./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
63317701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
63607201./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
63350101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
63569101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
63334201./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
63625201./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
63403201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
63596401./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120941./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120411./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90801./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300731./30000*sint
DELAY
Reaction time (period between GO and SR)
45131./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
27041./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
32401./30000*sint
PT
Movement time (period between SR and HEplat-ON)
59441./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
219001./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
193201./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2171./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
61intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
63764891./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_061
Information on digital trial events
Time when trial start event is internally activated.
63764891./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
63771331./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
63885861./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
64006671./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
64097071./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
64397871./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
64435801./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
64717881./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
64717911./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
64953201./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
64470901./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
64758001./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
64489201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
64734601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
64485301./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
64758301./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
64570201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
64710001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120971./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90401./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300801./30000*sint
DELAY
Reaction time (period between GO and SR)
37931./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
35101./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
18301./30000*sint
PT
Movement time (period between SR and HEplat-ON)
53401./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
245401./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
139801./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1481./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
62intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
64954681./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_062
Information on digital trial events
Time when trial start event is internally activated.
64954681./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
64960751./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
65075081./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
65196051./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
65290271./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
65591001./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
65646601./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
65829331./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
65829351./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
66008211./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
65673601./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
65946301./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
65698501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
65917201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
65693401./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
65925601./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
65740201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
65739901./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120401./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120971./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
94221./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300731./30000*sint
DELAY
Reaction time (period between GO and SR)
55601./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
27001./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
24901./30000*sint
PT
Movement time (period between SR and HEplat-ON)
51901./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
218701./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-301./30000*sint
HEplat
Inter-trial-interval (period until next trial)
9581./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
63intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
66017791./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_063
Information on digital trial events
Time when trial start event is internally activated.
66017791./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
66023631./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
66137901./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
66258651./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
66349391./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
66650161./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
66701561./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
66916271./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
66916291./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
67007011./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
67151921./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
66724501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
66997801./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
66749101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
66964801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
66734101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
66989101./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
66791101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
66948601./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120111./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90741./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300771./30000*sint
DELAY
Reaction time (period between GO and SR)
51401./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
22941./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
24601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
47541./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
215701./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
157501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
64intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
67153431./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
175intl101210-001.nev
PerformanceCode
Trial type of trial
SGstringl101210-001.nev
TrialType
Trial_064
Information on digital trial events
Time when trial start event is internally activated.
67153431./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
67162391./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
67276651./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
67397411./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
67488421./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
68194481./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
67597011./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
123221./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120761./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91011./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
65intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
68195971./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_065
Information on digital trial events
Time when trial start event is internally activated.
68195971./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
68201811./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
68833851./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
68233031./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
66intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
68835351./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_066
Information on digital trial events
Time when trial start event is internally activated.
68835351./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
68844291./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
68959041./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
69079861./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
69170601./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
69471341./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
69527531./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
69759541./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
69995171./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
69555901./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
69833101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
69577501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
69808201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
69568501./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
69839701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
69667801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
69817801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
123691./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120821./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90741./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
56191./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
28371./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
21601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
49971./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
230701./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
150001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
67intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
69996681./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
191intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_067
Information on digital trial events
Time when trial start event is internally activated.
69996681./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
70010001./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
70124531./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
70245341./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
70335731./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
70636551./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
70693931./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
71149831./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
127851./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90391./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300821./30000*sint
DELAY
Reaction time (period between GO and SR)
57381./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1521./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
68intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
71151351./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_068
Information on digital trial events
Time when trial start event is internally activated.
71151351./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
71157851./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
71272411./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
71393221./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
71483631./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
71784441./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
71833431./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
72092061./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
72092121./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
72329231./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
71862601./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
72149101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
71877601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
72089401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
71869801./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
72149401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
71943001./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
72108901./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121061./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90411./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
48991./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
29171./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
15001./30000*sint
PT
Movement time (period between SR and HEplat-ON)
44171./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
211801./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
165901./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2261./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
69intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
72331491./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_069
Information on digital trial events
Time when trial start event is internally activated.
72331491./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
72337281./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
72451571./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
72572311./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
72663281./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
72964021./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
73010631./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
73224551./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
73224591./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
73407431./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
73042801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
73318801./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
73064401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
73208101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
73058101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
73311901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
73096501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
73258801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120081./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90971./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
46611./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
32171./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
21601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
53771./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
143701./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
162301./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2261./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
70intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
73409691./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
191intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_070
Information on digital trial events
Time when trial start event is internally activated.
73409691./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
73416281./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
73531031./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
73651511./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
73742311./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
74043051./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
74114851./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
74600561./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121341./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120481./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90801./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
71801./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
71intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
74602061./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_071
Information on digital trial events
Time when trial start event is internally activated.
74602061./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
74608661./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
75234381./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
74639571./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1191./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
72intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
75235571./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
191intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_072
Information on digital trial events
Time when trial start event is internally activated.
75235571./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
75242021./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
75356601./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
75477011./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
75570021./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
75870421./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
75909021./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
76371951./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121031./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120411./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
93011./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300401./30000*sint
DELAY
Reaction time (period between GO and SR)
38601./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
73intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
76373461./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_073
Information on digital trial events
Time when trial start event is internally activated.
76373461./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
76379891./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
76494411./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
76614831./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
76705891./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
77006701./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
77053191./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
77241611./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
77241631./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
77416401./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
77082601./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
77361901./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
77109601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
77316601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
77097901./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
77296801./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
77150701./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
77157001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120951./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120421./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91061./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
46491./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
29411./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
27001./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56411./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
207001./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
6301./30000*sint
HEplat
Inter-trial-interval (period until next trial)
8711./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
74intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
77425111./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_074
Information on digital trial events
Time when trial start event is internally activated.
77425111./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
77431661./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
77545911./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
77666321./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
77758291./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
78059121./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
78103731./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
78338951./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
78574271./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
78135601./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
78433201./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
78151201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
78404101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
78144901./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
78425701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
78210001./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
78387901./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120801./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120411./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91971./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300831./30000*sint
DELAY
Reaction time (period between GO and SR)
44611./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
31871./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
15601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
47471./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
252901./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
177901./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
75intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
78575781./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_075
Information on digital trial events
Time when trial start event is internally activated.
78575781./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
78582101./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
79235131./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
78638821./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1921./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
76intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
79237051./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_076
Information on digital trial events
Time when trial start event is internally activated.
79237051./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
79245701./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
79940331./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
79342521./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
77intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
79941831./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_077
Information on digital trial events
Time when trial start event is internally activated.
79941831./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
79949941./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
80064301./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
80185111./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
80275501./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
80575991./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
80631941./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
80863151./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
80863171./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
81098801./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
80660701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
80934901./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
80679301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
80908501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
80676001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
80937901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
80744101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
80889601./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
122471./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90391./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300491./30000*sint
DELAY
Reaction time (period between GO and SR)
55951./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
28761./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
18601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
47361./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
229201./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
145501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
78intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
81100291./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_078
Information on digital trial events
Time when trial start event is internally activated.
81100291./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
81107481./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
81747281./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
81152161./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
79intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
81748771./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_079
Information on digital trial events
Time when trial start event is internally activated.
81748771./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
81754621./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
81869131./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
81989871./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
82080621./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
82381451./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
82417281./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
82609951./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
82609991./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
82785341./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
82452901./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
82726501./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
82467901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
82692901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
82469101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
82703401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
82528201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
82680001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120361./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90751./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300831./30000*sint
DELAY
Reaction time (period between GO and SR)
35831./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
35621./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
15001./30000*sint
PT
Movement time (period between SR and HEplat-ON)
50621./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
225001./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
151801./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2341./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
80intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
82787681./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_080
Information on digital trial events
Time when trial start event is internally activated.
82787681./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
82793471./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
82907741./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
83028501./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
83119481./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
83420211./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
83447601./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
83719181./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
83719231./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
83904121./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
83488501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
83749201./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
83511301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
83733901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
83499001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
83743801./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
83626501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
83695201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120061./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120761./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90981./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300731./30000*sint
DELAY
Reaction time (period between GO and SR)
27391./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
40901./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
22801./30000*sint
PT
Movement time (period between SR and HEplat-ON)
63701./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
222601./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
68701./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1521./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
81intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
83905641./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_081
Information on digital trial events
Time when trial start event is internally activated.
83905641./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
83912011./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
84026431./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
84146851./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
84237651./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
84538051./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
84578121./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
84810851./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
84810871./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
85048031./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
84613201./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
84889501./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
84632101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
84878101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
84624601./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
84910201./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
84697501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
84875101./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120791./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120421./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90801./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300401./30000*sint
DELAY
Reaction time (period between GO and SR)
40071./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
35081./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
18901./30000*sint
PT
Movement time (period between SR and HEplat-ON)
53981./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
246001./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
177601./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
82intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
85049541./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_082
Information on digital trial events
Time when trial start event is internally activated.
85049541./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
85055421./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
85169931./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
85290681./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
85382671./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
85683481./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
85707611./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
85972731./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
86208041./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
85746301./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
86035201./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
85765801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
86004901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
85764601./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
86049601./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
85869301./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
86030701./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120391./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91991./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
24131./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
38691./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
19501./30000*sint
PT
Movement time (period between SR and HEplat-ON)
58191./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
239101./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
161401./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
83intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
86209531./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_083
Information on digital trial events
Time when trial start event is internally activated.
86209531./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
86215881./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
86330151./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
86450901./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
86541881./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
86842621./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
86882951./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
87119091./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
87119141./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
87370831./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
86915401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
87221701./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
86939101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
87184201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
86936701./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
87233701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
87034501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
87202801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120621./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90981./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
40331./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
32451./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
23701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56151./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
245101./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
168301./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1021./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
84intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
87371851./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_084
Information on digital trial events
Time when trial start event is internally activated.
87371851./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
87378081./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
88069531./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
87464661./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1521./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
85intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
88071051./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_085
Information on digital trial events
Time when trial start event is internally activated.
88071051./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
88076781./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
88692801./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
88098041./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1531./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
86intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
88694331./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_086
Information on digital trial events
Time when trial start event is internally activated.
88694331./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
88700231./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
89355481./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
88760731./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
87intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
89356981./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_087
Information on digital trial events
Time when trial start event is internally activated.
89356981./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
89362901./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
89477401./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
89598151./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
89688901./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
89989721./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
90047121./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
90272881./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
90508531./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
90075001./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
90343501./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
90097501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
90322801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
90087301./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
90344701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
90297601./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
90153601./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120421./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90751./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300821./30000*sint
DELAY
Reaction time (period between GO and SR)
57401./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
27881./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
22501./30000*sint
PT
Movement time (period between SR and HEplat-ON)
50381./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
225301./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-144001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1531./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
88intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
90510061./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_088
Information on digital trial events
Time when trial start event is internally activated.
90510061./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
90519831./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
90634571./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
90755051./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
90845851./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
91146591./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
91179711./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
91460831./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
91460881./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
91696471./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
91223701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
91525501./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
91233301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
91491001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
91240501./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
91539601./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
91341901./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
91512601./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
124511./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120481./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90801./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
33121./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
43991./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
9601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
53591./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
257701./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
170701./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
89intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
91697971./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_089
Information on digital trial events
Time when trial start event is internally activated.
91697971./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
91703971./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
91818251./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
91938661./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
92029691./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
92330431./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
92350621./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
92605701./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
92605721./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
92842301./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
92392201./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
92685001./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
92411101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
92653801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
92409901./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
92693401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
92477701./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
92671801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120281./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120411./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91031./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
20191./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
41581./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
18901./30000*sint
PT
Movement time (period between SR and HEplat-ON)
60481./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
242701./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
194101./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2291./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
90intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
92844591./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
175intl101210-001.nev
PerformanceCode
Trial type of trial
PGstringl101210-001.nev
TrialType
Trial_090
Information on digital trial events
Time when trial start event is internally activated.
92844591./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
92850351./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
92964621./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
93085371./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
93175781./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
93897621./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
93301671./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120031./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90411./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2271./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
91intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
93899891./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_091
Information on digital trial events
Time when trial start event is internally activated.
93899891./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
93906191./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
94021071./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
94141481./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
94231951./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
94532751./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
94555951./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
94800611./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
94891051./30000*sintl101210-001.nev
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
95036241./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
94593001./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
94873801./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
94622101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
94843201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
94611601./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
94888201./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
94682101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
94862701./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121181./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120411./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90471./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300801./30000*sint
DELAY
Reaction time (period between GO and SR)
23201./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
37051./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
29101./30000*sint
PT
Movement time (period between SR and HEplat-ON)
66151./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
221101./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
180601./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
92intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
95037731./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_092
Information on digital trial events
Time when trial start event is internally activated.
95037731./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
95043471./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
95158141./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
95278621./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
95369421./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
95670161./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
95705091./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
95968051./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
95968071./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
96205731./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
95738701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
96047101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
95764501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
96012901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
95757901./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
96056401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
95880301./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
96025501./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120411./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120481./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90801./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
34931./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
33611./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
25801./30000*sint
PT
Movement time (period between SR and HEplat-ON)
59411./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
248401./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
145201./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1601./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
93intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
96207331./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_093
Information on digital trial events
Time when trial start event is internally activated.
96207331./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
96213271./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
96327651./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
96448391./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
96538791./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
96839581./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
96889181./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
97129091./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
97219531./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
97372791./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
96921001./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
97221001./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
96951901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
97186501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
96942301./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
97237501./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
97009801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
97205401./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120321./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90401./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300791./30000*sint
DELAY
Reaction time (period between GO and SR)
49601./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
31821./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
30901./30000*sint
PT
Movement time (period between SR and HEplat-ON)
62721./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
234601./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
195601./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
94intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
97374301./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_094
Information on digital trial events
Time when trial start event is internally activated.
97374301./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
97380441./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
97494711./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
97615471./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
97706451./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
98007191./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
98047181./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
98297421./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
98534251./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
98086201./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
98373601./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
98110501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
98345401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
98104201./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
98385601./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
98184301./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
98356201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120411./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120761./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90981./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
39991./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
39021./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
24301./30000*sint
PT
Movement time (period between SR and HEplat-ON)
63321./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
234901./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
171901./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
95intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
98535751./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_095
Information on digital trial events
Time when trial start event is internally activated.
98535751./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
98541771./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
99195691./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
98598171./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1611./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
96intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
99197301./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
167intl101210-001.nev
PerformanceCode
Trial type of trial
PGstringl101210-001.nev
TrialType
Trial_096
Information on digital trial events
Time when trial start event is internally activated.
99197301./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
99203541./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
99318081./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
99439991./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
100074531./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
99478811./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120781./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
121911./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
97intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
100076041./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_097
Information on digital trial events
Time when trial start event is internally activated.
100076041./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
100088321./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
100202881./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
100323361./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
100417291./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
100718101./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
100775501./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
100956321./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
100956351./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
101132571./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
100802401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
101061001./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
100823701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
101016601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
100809601./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
101032501./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
100866601./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
100993501./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
126841./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120481./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
93931./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
57401./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
26901./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
21301./30000*sint
PT
Movement time (period between SR and HEplat-ON)
48201./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
192901./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
126901./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1741./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
98intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
101134311./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_098
Information on digital trial events
Time when trial start event is internally activated.
101134311./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
101140641./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
101254931./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
101375681./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
101466081./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
101767181./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
101827911./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
102055021./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
102290651./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
101856901./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
102126601./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
101879101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
102086401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
101873101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
102125701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
101927701./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
102093301./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120621./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90401./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
301101./30000*sint
DELAY
Reaction time (period between GO and SR)
60731./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
28991./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
22201./30000*sint
PT
Movement time (period between SR and HEplat-ON)
51191./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
207301./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
165601./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2321./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
99intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
102292971./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
191intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_099
Information on digital trial events
Time when trial start event is internally activated.
102292971./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
102298721./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
102413821./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
102534251./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
102625591./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
102926811./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
102978421./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
103265231./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120851./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120431./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91341./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
301221./30000*sint
DELAY
Reaction time (period between GO and SR)
51611./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
75591./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
100intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
103340821./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
163intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_100
Information on digital trial events
Time when trial start event is internally activated.
103340821./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
103346631./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
103461081./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
104088101./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
103493021./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120261./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
101intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
104089591./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
163intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_101
Information on digital trial events
Time when trial start event is internally activated.
104089591./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
104095481./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
104209801./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
104938961./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
104339681./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120211./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
102intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
104940461./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_102
Information on digital trial events
Time when trial start event is internally activated.
104940461./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
104955941./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
105070491./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
105190961./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
105284001./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
105584761./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
105636661./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
105882831./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
105882851./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
106119671./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
105669301./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
105936001./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
105699001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
105918601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
105689401./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
105952501./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
105785101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
105929701./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
130031./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120471./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
93041./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300761./30000*sint
DELAY
Reaction time (period between GO and SR)
51901./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
32641./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
29701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
62341./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
219601./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
144601./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1481./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
103intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
106121151./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_103
Information on digital trial events
Time when trial start event is internally activated.
106121151./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
106126861./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
106821161./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
106221091./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1691./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
104intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
106822851./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_104
Information on digital trial events
Time when trial start event is internally activated.
106822851./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
106828811./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
106943101./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
107063851./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
107154831./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
107455571./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
107491101./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
107734901./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
107734941./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
107825361./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
107970811./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
107519101./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
107804701./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
107540101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
107775901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
107541901./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
107815501./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
107634001./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
107791501./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120251./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90981./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
35531./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
28001./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
21001./30000*sint
PT
Movement time (period between SR and HEplat-ON)
49001./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
235801./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
157501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1061./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
105intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
107971871./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_105
Information on digital trial events
Time when trial start event is internally activated.
107971871./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
107978131./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
108638431./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
108043331./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
106intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
108639931./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_106
Information on digital trial events
Time when trial start event is internally activated.
108639931./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
108649301./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
108763581./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
108883991./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
108977191./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
109278001./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
109337871./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
109566271./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
109566321./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
109656721./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
109801941./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
109364701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
109636501./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
109385701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
109470301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
109388701./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
109652101./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
109459801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
109626601./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
123651./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120411./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
93201./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
59871./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
26831./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
21001./30000*sint
PT
Movement time (period between SR and HEplat-ON)
47831./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
84601./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
166801./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
107intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
109803441./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_107
Information on digital trial events
Time when trial start event is internally activated.
109803441./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
109809451./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
109923991./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
110044461./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
110134931./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
110435731./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
110482331./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
110723191./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
110723231./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
110959991./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
110511001./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
110798701./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
110532901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
110768401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
110542201./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
110812801./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
110610301./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
110786401./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120551./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120471./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90471./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300801./30000*sint
DELAY
Reaction time (period between GO and SR)
46601./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
28671./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
21901./30000*sint
PT
Movement time (period between SR and HEplat-ON)
50571./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
235501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
176101./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
108intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
110961491./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_108
Information on digital trial events
Time when trial start event is internally activated.
110961491./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
110967231./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
111081501./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
111202261./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
111293251./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
111593991./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
111633121./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
111870441./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
112106081./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
111666901./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
111952501./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
111689101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
111917401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
111683101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
111964201./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
111775801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
111933601./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120011./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120761./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90991./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
39131./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
33781./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
22201./30000*sint
PT
Movement time (period between SR and HEplat-ON)
55981./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
228301./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
157801./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
109intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
112107591./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_109
Information on digital trial events
Time when trial start event is internally activated.
112107591./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
112115941./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
112782431./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
112184681./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1351./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
110intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
112783781./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_110
Information on digital trial events
Time when trial start event is internally activated.
112783781./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
112790351./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
113448031./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
112852041./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1091./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
111intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
113449121./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_111
Information on digital trial events
Time when trial start event is internally activated.
113449121./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
113455671./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
114154641./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
113559551./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
112intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
114156151./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_112
Information on digital trial events
Time when trial start event is internally activated.
114156151./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
114162011./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
114276421./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
114397221./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
114487951./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
114788361./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
114841031./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
115057921./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
115057961./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
115293561./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
114866701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
115129801./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
114888001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
115106401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
114882001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
115137301./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
114926701./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
115106701./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120271./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120801./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300411./30000*sint
DELAY
Reaction time (period between GO and SR)
52671./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
25671./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
21301./30000*sint
PT
Movement time (period between SR and HEplat-ON)
46971./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
218401./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
180001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1421./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
113intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
115294981./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_113
Information on digital trial events
Time when trial start event is internally activated.
115294981./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
115300781./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
115415281./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
115535691./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
115626491./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
115927231./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
115954021./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
116188431./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
116188481./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
116425041./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
115992001./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
116249101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
116022601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
116218801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
116006701./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
116268001./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
116072701./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
116239201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120301./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120411./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90801./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
26791./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
37981./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
30601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
68581./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
196201./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
166501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2351./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
114intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
116427391./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_114
Information on digital trial events
Time when trial start event is internally activated.
116427391./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
116433361./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
116548121./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
116668931./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
116759661./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
117060401./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
117095331./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
117353261./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
117353301./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
117443701./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
117590101./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
117131401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
117410101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
117150601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
117373801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
117154501./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
117416701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
117223501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
117394801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120731./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
34931./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
36071./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
19201./30000*sint
PT
Movement time (period between SR and HEplat-ON)
55271./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
223201./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
171301./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
115intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
117591591./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
167intl101210-001.nev
PerformanceCode
Trial type of trial
SGstringl101210-001.nev
TrialType
Trial_115
Information on digital trial events
Time when trial start event is internally activated.
117591591./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
117597591./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
117711841./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
117833311./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
118479071./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
117883121./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120251./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
121471./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
3481./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
116intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
118482551./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_116
Information on digital trial events
Time when trial start event is internally activated.
118482551./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
118494661./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
119168491./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
118569531./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
117intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
119169981./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_117
Information on digital trial events
Time when trial start event is internally activated.
119169981./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
119175801./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
119290261./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
119411051./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
119501791./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
119802631./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
119835161./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
120067881./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
120303511./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
119873401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
120126001./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
119887801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
120109201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
119883601./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
120107701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
119947501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
120051001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120281./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120791./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90741./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300841./30000*sint
DELAY
Reaction time (period between GO and SR)
32531./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
38241./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
14401./30000*sint
PT
Movement time (period between SR and HEplat-ON)
52641./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
221401./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
103501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1241./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
118intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
120304751./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_118
Information on digital trial events
Time when trial start event is internally activated.
120304751./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
120311901./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
120426151./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
120546961./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
120637371./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
120938171./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
120971891./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
121222181./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
121222231./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
121457831./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
121006501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
121294201./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
121028401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
121258201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
121027801./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
121304401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
121130701./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
121270801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121401./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90411./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300801./30000*sint
DELAY
Reaction time (period between GO and SR)
33721./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
34611./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
21901./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56511./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
229801./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
140101./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
119intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
121459331./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_119
Information on digital trial events
Time when trial start event is internally activated.
121459331./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
121472931./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
121587201./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
121707951./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
121798681./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
122101011./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
122145541./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
122380521./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
122380571./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
122617771./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
122171101./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
122444101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
122195701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
122408701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
122184901./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
122446201./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
122250901./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
122400901./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
127871./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
302331./30000*sint
DELAY
Reaction time (period between GO and SR)
44531./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
25561./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
24601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
50161./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
213001./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
150001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1561./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
120intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
122619331./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_120
Information on digital trial events
Time when trial start event is internally activated.
122619331./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
122633661./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
123292531./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
122694761./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
781./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
121intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
123293311./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
175intl101210-001.nev
PerformanceCode
Trial type of trial
SGstringl101210-001.nev
TrialType
Trial_121
Information on digital trial events
Time when trial start event is internally activated.
123293311./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
123299851./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
123414091./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
123534571./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
123625361./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
124340711./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
123745911./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120781./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120481./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90791./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1661./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
122intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
124342371./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_122
Information on digital trial events
Time when trial start event is internally activated.
124342371./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
124348931./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
124463421./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
124583771./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
124674851./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
124975321./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
125039981./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
125290241./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
125290281./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
125525871./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
125069701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
125332201./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
125102401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
125316601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
125100601./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
125331301./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
125141701./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
125289001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121051./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120351./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91081./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300471./30000*sint
DELAY
Reaction time (period between GO and SR)
64661./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
29721./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
32701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
62421./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
214201./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
147301./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1871./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
123intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
125527741./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_123
Information on digital trial events
Time when trial start event is internally activated.
125527741./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
125533751./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
125648411./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
125769221./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
125859951./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
126160691./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
126214821./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
126452731./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
126452771./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
126689871./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
126252001./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
126546901./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
126268201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
126358501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
126265201./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
126552301./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
126331201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
126519901./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120671./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
54131./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
37181./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
16201./30000*sint
PT
Movement time (period between SR and HEplat-ON)
53381./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
90301./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
188701./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
124intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
126691381./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_124
Information on digital trial events
Time when trial start event is internally activated.
126691381./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
126704101./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
127392181./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
126798011./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1531./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
125intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
127393711./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_125
Information on digital trial events
Time when trial start event is internally activated.
127393711./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
127400221./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
127514741./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
127635151./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
127728231./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
128028971./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
128083101./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
128312461./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
128312481./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
128549281./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
128114101./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
128389801./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
128132701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
128351101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
128129101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
128392801./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
128192401./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
128363401./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121031./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120411./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
93081./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
54131./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
31001./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
18601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
49601./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
218401./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
171001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
126intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
128550771./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_126
Information on digital trial events
Time when trial start event is internally activated.
128550771./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
128556501./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
128670791./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
128791581./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
128882531./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
129183261./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
129202861./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
129447111./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
129447141./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
129683701./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
129238501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
129529801./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
129259201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
129497401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
129254701./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
129530701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
129343801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
129491701./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120021./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120791./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90951./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300731./30000*sint
DELAY
Reaction time (period between GO and SR)
19601./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
35641./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
20701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56341./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
238201./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
147901./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2701./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
127intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
129686401./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_127
Information on digital trial events
Time when trial start event is internally activated.
129686401./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
129692331./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
129806601./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
129927351./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
130018351./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
130319081./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
130357011./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
130592341./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
130592371./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
130827981./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
130395001./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
130682701./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
130437901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
130651801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
130404001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
130681201./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
130464001./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
130639801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120201./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91001./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300731./30000*sint
DELAY
Reaction time (period between GO and SR)
37931./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
37991./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
42901./30000*sint
PT
Movement time (period between SR and HEplat-ON)
80891./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
213901./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
175801./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
128intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
130829481./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_128
Information on digital trial events
Time when trial start event is internally activated.
130829481./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
130836061./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
130950581./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
131071071./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
131161791./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
131464151./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
131498091./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
131723471./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
131813921./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
131972371./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
131537101./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
131822701./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
131557501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
131791501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
131537701./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
131837401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
131628301./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
131778301./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121101./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120491./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90721./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
302361./30000*sint
DELAY
Reaction time (period between GO and SR)
33941./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
39011./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
20401./30000*sint
PT
Movement time (period between SR and HEplat-ON)
59411./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
234001./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
150001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1551./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
129intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
131973921./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_129
Information on digital trial events
Time when trial start event is internally activated.
131973921./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
131979811./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
132658841./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
132051741./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
5541./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
130intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
132664381./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_130
Information on digital trial events
Time when trial start event is internally activated.
132664381./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
132670301./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
132784591./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
132905341./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
132996321./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
133297061./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
133348191./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
133606911./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
133842781./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
133383301./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
133653301./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
133406701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
133574701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
133389301./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
133668301./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
133497301./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
133640101./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120211./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90981./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
51131./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
35111./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
23401./30000*sint
PT
Movement time (period between SR and HEplat-ON)
58511./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
168001./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
142801./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1031./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
131intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
133843811./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_131
Information on digital trial events
Time when trial start event is internally activated.
133843811./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
133850371./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
134545361./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
133944581./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
132intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
134546851./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_132
Information on digital trial events
Time when trial start event is internally activated.
134546851./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
134552611./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
134667131./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
134787541./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
134878341./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
135180681./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
135215011./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
135437341./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
135437381./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
135673911./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
135249001./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
135527401./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
135262501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
135483301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
135264901./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
135535501./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
135321001./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
135510301./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120281./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120411./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90801./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
302341./30000*sint
DELAY
Reaction time (period between GO and SR)
34331./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
33991./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
13501./30000*sint
PT
Movement time (period between SR and HEplat-ON)
47491./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
220801./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
189301./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
133intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
135675421./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_133
Information on digital trial events
Time when trial start event is internally activated.
135675421./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
135683741./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
135798231./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
135918961./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
136010981./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
136311791./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
136338311./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
136593401./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
136683841./30000*sintl101210-001.nev
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
136828711./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
136377001./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
136659901./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
136396801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
136623901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
136393201./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
136674901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
136489801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
136648201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
122811./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120731./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
92021./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
26521./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
38691./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
19801./30000*sint
PT
Movement time (period between SR and HEplat-ON)
58491./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
227101./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
158401./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1481./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
134intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
136830191./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_134
Information on digital trial events
Time when trial start event is internally activated.
136830191./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
136835971./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
137548131./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
136953311./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
135intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
137549641./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_135
Information on digital trial events
Time when trial start event is internally activated.
137549641./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
137558421./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
137673011./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
137793831./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
137884721./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
138185501./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
138214871./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
138439651./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
138439671./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
138675331./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
138249601./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
138518101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
138274201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
138486601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
138264001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
138529201./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
138320101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
138498001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
123371./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120821./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90891./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300781./30000*sint
DELAY
Reaction time (period between GO and SR)
29371./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
34731./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
24601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
59331./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
212401./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
177901./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1581./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
136intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
138676911./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_136
Information on digital trial events
Time when trial start event is internally activated.
138676911./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
138683411./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
138798151./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
138918971./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
139009711./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
139310441./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
139359771./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
139614431./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
139614461./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
139851231./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
139397401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
139668601./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
139417801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
139641301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
139409101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
139673701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
139524901./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
139623601./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121241./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120821./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90741./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300731./30000*sint
DELAY
Reaction time (period between GO and SR)
49331./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
37631./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
20401./30000*sint
PT
Movement time (period between SR and HEplat-ON)
58031./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
223501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
98701./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1191./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
137intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
139852421./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
167intl101210-001.nev
PerformanceCode
Trial type of trial
PGstringl101210-001.nev
TrialType
Trial_137
Information on digital trial events
Time when trial start event is internally activated.
139852421./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
139858781./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
139973281./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
140094021./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
140766351./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
140169771./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120861./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
138intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
140767851./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_138
Information on digital trial events
Time when trial start event is internally activated.
140767851./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
140774301./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
141417561./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
140822791./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1241./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
139intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
141418801./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_139
Information on digital trial events
Time when trial start event is internally activated.
141418801./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
141427601./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
141542141./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
141662951./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
141753351./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
142054171./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
142078921./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
142308521./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
142308541./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
142544661./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
142118401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
142392901./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
142145401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
142368901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
142125601./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
142398001./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
142188001./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
142374601./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
123341./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90401./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300821./30000*sint
DELAY
Reaction time (period between GO and SR)
24751./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
39481./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
27001./30000*sint
PT
Movement time (period between SR and HEplat-ON)
66481./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
223501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
186601./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
140intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
142546151./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_140
Information on digital trial events
Time when trial start event is internally activated.
142546151./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
142551981./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
142666261./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
142787021./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
142877991./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
143178731./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
143213671./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
143453431./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
143453461./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
143543851./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
143690221./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
143250001./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
143547601./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
143283601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
143495701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
143258701./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
143545501./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
143326201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
143514001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120111./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120761./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90971./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
34941./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
36331./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
33601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
69931./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
212101./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
187801./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
141intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
143691721./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_141
Information on digital trial events
Time when trial start event is internally activated.
143691721./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
143698081./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
144390021./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
143795201./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
142intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
144391511./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
191intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_142
Information on digital trial events
Time when trial start event is internally activated.
144391511./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
144397961./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
144512471./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
144632891./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
144723691./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
145024431./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
145652851./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
145047291./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120961./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120421./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90801./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
-145024441./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
3321./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
143intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
145656171./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_143
Information on digital trial events
Time when trial start event is internally activated.
145656171./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
145666491./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
146280281./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
145682771./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1041./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
144intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
146281321./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_144
Information on digital trial events
Time when trial start event is internally activated.
146281321./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
146287841./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
146922091./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
146327001./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
145intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
146923591./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_145
Information on digital trial events
Time when trial start event is internally activated.
146923591./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
146929451./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
147043951./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
147164721./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
147255441./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
147556331./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
147600021./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
147817701./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
147817761./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
148054321./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
147625801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
147868801./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
147649501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
147829501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
147634201./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
147837001./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
147690601./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
147785701./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120361./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120771./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90721./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300891./30000*sint
DELAY
Reaction time (period between GO and SR)
43691./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
25781./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
23701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
49481./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
180001./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
95101./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2171./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
146intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
148056491./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_146
Information on digital trial events
Time when trial start event is internally activated.
148056491./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
148062941./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
148177211./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
148297951./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
148388681./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
148690721./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
148745721./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
148988431./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
148988481./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
149224061./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
148777501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
149054401./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
148798501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
149024401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
148797601./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
149072701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
148875001./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
149040301./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120721./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
302041./30000*sint
DELAY
Reaction time (period between GO and SR)
55001./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
31781./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
21001./30000*sint
PT
Movement time (period between SR and HEplat-ON)
52781./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
225901./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
165301./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
147intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
149225571./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_147
Information on digital trial events
Time when trial start event is internally activated.
149225571./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
149231561./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
149346051./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
149466801./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
149559791./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
149860681./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
149892671./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
150124531./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
150215001./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
150360181./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
149926201./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
150214201./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
149949001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
150175501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
149941801./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
150210301./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
150004501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
150150901./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120481./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
92991./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300891./30000*sint
DELAY
Reaction time (period between GO and SR)
31991./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
33531./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
22801./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56331./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
226501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
146401./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
148intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
150361681./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_148
Information on digital trial events
Time when trial start event is internally activated.
150361681./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
150367691./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
150481971./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
150602711./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
150693431./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
150994511./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
151011701./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
151248621./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
151248671./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
151485991./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
151048801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
151328701./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
151079101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
151296301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
151064401./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
151327501./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
151126201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
151246201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120291./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90721./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
301081./30000*sint
DELAY
Reaction time (period between GO and SR)
17191./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
37101./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
30301./30000*sint
PT
Movement time (period between SR and HEplat-ON)
67401./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
217201./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
120001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1281./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
149intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
151487271./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_149
Information on digital trial events
Time when trial start event is internally activated.
151487271./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
151493261./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
151607621./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
151728361./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
151818761./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
152119561./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
152167691./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
152401181./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
152401201./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
152636821./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
152203801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
152478001./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
152228401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
152333701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
152218501./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
152494501./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
152291701./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
152472001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120351./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90401./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300801./30000*sint
DELAY
Reaction time (period between GO and SR)
48131./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
36111./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
24601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
60711./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
105301./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
180301./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
150intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
152638331./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_150
Information on digital trial events
Time when trial start event is internally activated.
152638331./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
152644611./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
153354151./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
152758141./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
3751./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
151intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
153357901./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_151
Information on digital trial events
Time when trial start event is internally activated.
153357901./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
153364701./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
154011441./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
153403551./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2321./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
152intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
154013761./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_152
Information on digital trial events
Time when trial start event is internally activated.
154013761./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
154020651./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
154135131./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
154255871./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
154346601./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
154647001./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
154681671./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
154882691./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
154882751./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
155060471./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
154720501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
154965601./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
154738801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
154925401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
154725901./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
154965001./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
154777201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
154929301./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121371./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300401./30000*sint
DELAY
Reaction time (period between GO and SR)
34671./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
38831./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
18301./30000*sint
PT
Movement time (period between SR and HEplat-ON)
57131./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
186601./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
152101./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
153intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
155061971./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_153
Information on digital trial events
Time when trial start event is internally activated.
155061971./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
155067711./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
155181981./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
155302721./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
155393731./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
155694471./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
155759061./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
155836611./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
155836661./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
155982371./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
155790901./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
155958301./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
155814601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
155933401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
155803201./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
155939401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
155830201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
155908501./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120011./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91011./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
64591./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
31841./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
23701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
55541./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
118801./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
78301./30000*sint
HEplat
Inter-trial-interval (period until next trial)
39161./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
154intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
156021531./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_154
Information on digital trial events
Time when trial start event is internally activated.
156021531./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
156027751./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
156142031./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
156262771./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
156353501./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
156654511./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
156714371./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
156818871./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
156818901./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
156964241./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
156744301./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
156926401./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
156771001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
156889501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
156762301./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
156907201./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
156813001./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
156874201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120501./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
301011./30000*sint
DELAY
Reaction time (period between GO and SR)
59861./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
29931./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
26701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56631./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
118501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
61201./30000*sint
HEplat
Inter-trial-interval (period until next trial)
18561./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
155intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
156982801./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_155
Information on digital trial events
Time when trial start event is internally activated.
156982801./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
156989251./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
157103531./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
157224281./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
157315001./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
157615751./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
157697481./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
157961301./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
157961321./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
158197431./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
157735801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
158016301./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
157764601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
157994101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
157753201./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
158034901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
157895101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
157978201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120731./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90721./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300751./30000*sint
DELAY
Reaction time (period between GO and SR)
81731./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
38321./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
28801./30000*sint
PT
Movement time (period between SR and HEplat-ON)
67121./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
229501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
83101./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1531./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
156intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
158198961./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_156
Information on digital trial events
Time when trial start event is internally activated.
158198961./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
158204771./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
158319261./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
158440091./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
158530821./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
158831611./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
158895291./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
159161611./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
159161661./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
159396931./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
158927701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
159233701./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
158946001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
159197401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
158955301./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
159244801./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
159048601./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
159223201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120301./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120831./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300791./30000*sint
DELAY
Reaction time (period between GO and SR)
63681./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
32411./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
18301./30000*sint
PT
Movement time (period between SR and HEplat-ON)
50711./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
251401./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
174601./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2421./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
157intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
159399351./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_157
Information on digital trial events
Time when trial start event is internally activated.
159399351./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
159405301./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
159519861./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
159640671./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
159731081./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
160031881./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
160083621./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
160322001./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
160322021./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
160558581./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
160115701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
160386601./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
160144201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
160361401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
160132501./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
160391401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
160217701./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
160354801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120511./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90411./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300801./30000*sint
DELAY
Reaction time (period between GO and SR)
51741./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
32081./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
28501./30000*sint
PT
Movement time (period between SR and HEplat-ON)
60581./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
217201./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
137101./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
158intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
160560091./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
191intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_158
Information on digital trial events
Time when trial start event is internally activated.
160560091./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
160571931./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
160686471./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
160806931./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
160897401./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
161198211./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
161229801./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
161518741./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
126381./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120461./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90471./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
31591./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
66751./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
159intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
161585491./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_159
Information on digital trial events
Time when trial start event is internally activated.
161585491./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
161591711./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
162316091./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
161719921./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1911./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
160intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
162318001./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
191intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_160
Information on digital trial events
Time when trial start event is internally activated.
162318001./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
162324421./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
162438921./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
162559681./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
162650461./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
162951201./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
163007991./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
163303531./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120921./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120761./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90781./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
56791./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
61871./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
161intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
163365401./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_161
Information on digital trial events
Time when trial start event is internally activated.
163365401./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
163371171./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
163485461./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
163606211./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
163697201./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
163997931./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
164052931./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
164279071./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
164279111./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
164369511./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
164516201./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
164075401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
164358301./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
164095501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
164335801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
164100901./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
164363401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
164156401./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
164287801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120061./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90991./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300731./30000*sint
DELAY
Reaction time (period between GO and SR)
55001./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
22471./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
20101./30000*sint
PT
Movement time (period between SR and HEplat-ON)
42571./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
240301./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
131401./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
162intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
164517701./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
167intl101210-001.nev
PerformanceCode
Trial type of trial
SGstringl101210-001.nev
TrialType
Trial_162
Information on digital trial events
Time when trial start event is internally activated.
164517701./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
164523731./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
164638261./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
164758731./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
165444501./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
164847011./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120561./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120471./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
163intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
165445991./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_163
Information on digital trial events
Time when trial start event is internally activated.
165445991./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
165451821./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
165566511./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
165686921./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
165777991./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
166079961./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
166122101./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
166350621./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
166350661./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
166587121./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
166156201./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
166428601./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
166188301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
166386901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
166168801./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
166445101./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
166248601./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
166412401./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120521./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120411./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91071./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
301971./30000*sint
DELAY
Reaction time (period between GO and SR)
42141./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
34101./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
32101./30000*sint
PT
Movement time (period between SR and HEplat-ON)
66201./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
198601./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
163801./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
164intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
166588621./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_164
Information on digital trial events
Time when trial start event is internally activated.
166588621./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
166594951./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
166709471./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
166830221./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
166920991./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
167224051./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
167277841./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
167553571./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
167553601./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
167788851./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
167315401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
167596501./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
167335501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
167571301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
167341501./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
167611801./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
167452801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
167583001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120851./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90771./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
303061./30000*sint
DELAY
Reaction time (period between GO and SR)
53791./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
37561./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
20101./30000*sint
PT
Movement time (period between SR and HEplat-ON)
57661./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
235801./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
130201./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
165intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
167790351./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_165
Information on digital trial events
Time when trial start event is internally activated.
167790351./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
167796111./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
167910611./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
168031371./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
168124231./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
168425031./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
168459361./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
168708411./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
168708431./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
168944061./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
168502501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
168791101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
168533401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
168771901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
168515101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
168796501./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
168607201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
168758701./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120261./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120761./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
92861./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300801./30000*sint
DELAY
Reaction time (period between GO and SR)
34331./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
43141./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
30901./30000*sint
PT
Movement time (period between SR and HEplat-ON)
74041./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
238501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
151501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1521./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
166intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
168945581./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_166
Information on digital trial events
Time when trial start event is internally activated.
168945581./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
168951581./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
169066481./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
169186891./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
169277351./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
169578431./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
169629021./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
169875271./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
169875321./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
170111861./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
169693201./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
169947301./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
169715701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
169735501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
169699801./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
169970101./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
169762501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
169895701./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120901./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120411./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90461./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
301081./30000*sint
DELAY
Reaction time (period between GO and SR)
50591./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
64181./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
22501./30000*sint
PT
Movement time (period between SR and HEplat-ON)
86681./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
19801./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
133201./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
167intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
170113361./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
191intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_167
Information on digital trial events
Time when trial start event is internally activated.
170113361./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
170119931./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
170234171./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
170354911./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
170445651./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
170746391./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
170811191./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
171297311./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120811./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90741./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
64801./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
168intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
171298811./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_168
Information on digital trial events
Time when trial start event is internally activated.
171298811./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
171305291./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
171419581./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
171539991./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
171630801./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
171931801./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
171992201./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
172221631./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
172221661./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
172312081./30000*sintl101210-001.nev
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
172460101./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
172021501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
172316701./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
172042201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
172296001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
172038301./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
172320301./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
172162201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
172269601./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120771./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120411./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90811./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
301001./30000*sint
DELAY
Reaction time (period between GO and SR)
60401./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
29301./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
20701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
50001./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
253801./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
107401./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
169intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
172461611./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_169
Information on digital trial events
Time when trial start event is internally activated.
172461611./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
172468021./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
172582511./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
172703261./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
172794051./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
173096401./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
173154331./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
173388791./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
173388811./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
173625801./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
173183101./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
173484301./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
173207401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
173452501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
173208001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
173490901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
173263801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
173409301./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120901./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90791./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
302351./30000*sint
DELAY
Reaction time (period between GO and SR)
57931./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
28771./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
24301./30000*sint
PT
Movement time (period between SR and HEplat-ON)
53071./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
245101./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
145501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
170intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
173627291./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
175intl101210-001.nev
PerformanceCode
Trial type of trial
SGstringl101210-001.nev
TrialType
Trial_170
Information on digital trial events
Time when trial start event is internally activated.
173627291./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
173633741./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
173748251./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
173869051./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
173959761./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
174690441./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
174093551./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120961./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120801./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90711./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1081./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
171intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
174691521./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_171
Information on digital trial events
Time when trial start event is internally activated.
174691521./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
174698071./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
174812341./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
174933081./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
175024991./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
175325791./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
175381091./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
175626161./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
175716631./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
175861821./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
175410001./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
175698001./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
175437301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
175659001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
175430401./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
175707901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
175531801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
175674001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120821./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91911./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300801./30000*sint
DELAY
Reaction time (period between GO and SR)
55301./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
28911./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
27301./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56211./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
221701./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
142201./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
172intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
175863321./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_172
Information on digital trial events
Time when trial start event is internally activated.
175863321./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
175869911./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
175984201./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
176105061./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
176196131./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
176496621./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
176532191./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
176764911./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
176764951./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
177000201./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
176571901./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
176854801./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
176591701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
176819401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
176582701./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
176855401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
176651401./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
176822401./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120881./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120861./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91071./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300491./30000*sint
DELAY
Reaction time (period between GO and SR)
35571./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
39711./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
19801./30000*sint
PT
Movement time (period between SR and HEplat-ON)
59511./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
227701./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
171001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2261./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
173intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
177002461./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_173
Information on digital trial events
Time when trial start event is internally activated.
177002461./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
177008951./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
177123231./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
177243971./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
177334711./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
177635451./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
177684451./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
177913331./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
177913351./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
178003801./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
178156191./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
177716401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
177996901./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
177750601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
177962401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
177731101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
178017001./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
177798901./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
177977401./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120771./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90741./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
49001./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
31951./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
34201./30000*sint
PT
Movement time (period between SR and HEplat-ON)
66151./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
211801./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
178501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
174intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
178157691./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_174
Information on digital trial events
Time when trial start event is internally activated.
178157691./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
178164391./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
178278861./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
178399661./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
178490401./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
178790811./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
178852471./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
179098081./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
179098131./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
179188521./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
179335211./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
178888801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
179188201./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
178906201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
179145901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
178915201./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
179196901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
178988101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
179161501./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121171./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120801./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90741./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300411./30000*sint
DELAY
Reaction time (period between GO and SR)
61661./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
36331./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
17401./30000*sint
PT
Movement time (period between SR and HEplat-ON)
53731./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
239701./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
173401./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1491./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
175intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
179336701./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_175
Information on digital trial events
Time when trial start event is internally activated.
179336701./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
179342731./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
180061021./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
179465341./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1091./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
176intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
180062111./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_176
Information on digital trial events
Time when trial start event is internally activated.
180062111./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
180068101./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
180182861./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
180303611./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
180398231./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
180700571./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
180729161./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
180954881./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
180954931./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
181191771./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
180757201./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
181038301./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
180779401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
181003501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
180782701./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
181055101./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
180878701./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
181024501./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120751./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
94621./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
302341./30000*sint
DELAY
Reaction time (period between GO and SR)
28591./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
28041./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
22201./30000*sint
PT
Movement time (period between SR and HEplat-ON)
50241./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
224101./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
145801./30000*sint
HEplat
Inter-trial-interval (period until next trial)
7781./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
177intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
181199551./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_177
Information on digital trial events
Time when trial start event is internally activated.
181199551./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
181205391./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
181319921./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
181440401./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
181530861./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
181831671./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
181871411./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
182107151./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
182107171./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
182342461./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
181912201./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
182192401./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
181940701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
182158801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
181923001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
182196601./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
181991101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
182161801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120371./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120481./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90461./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
39741./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
40791./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
28501./30000*sint
PT
Movement time (period between SR and HEplat-ON)
69291./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
218101./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
170701./30000*sint
HEplat
Inter-trial-interval (period until next trial)
7461./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
178intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
182349921./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_178
Information on digital trial events
Time when trial start event is internally activated.
182349921./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
182355841./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
182470391./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
182590871./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
182681661./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
182982411./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
183019401./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
183256991./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
183257041./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
183492301./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
183062401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
183335401./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
183086101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
183302701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
183072001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
183348901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
183140101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
183320701./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120471./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120481./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90791./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300751./30000*sint
DELAY
Reaction time (period between GO and SR)
36991./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
43001./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
23701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
66701./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
216601./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
180601./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2241./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
179intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
183494541./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_179
Information on digital trial events
Time when trial start event is internally activated.
183494541./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
183500461./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
183614741./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
183735491./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
183826471./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
184127211./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
184179541./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
184419781./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
184659881./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
184220101./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
184510801./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
184231501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
184474501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
184225801./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
184521901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
184316401./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
184461301./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120201./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90981./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
52331./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
40561./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
11401./30000*sint
PT
Movement time (period between SR and HEplat-ON)
51961./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
243001./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
144901./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1341./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
180intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
184661221./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_180
Information on digital trial events
Time when trial start event is internally activated.
184661221./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
184667041./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
184781881./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
184902351./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
184992811./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
185293621./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
185307221./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
185579031./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
185669751./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
185814701./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
185347801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
185649601./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
185366401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
185442901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
185360401./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
185666701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
185478601./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
185637301./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120661./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120471./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90461./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
13601./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
40581./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
18601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
59181./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
76501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
158701./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2431./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
181intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
185817131./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_181
Information on digital trial events
Time when trial start event is internally activated.
185817131./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
185823641./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
185938181./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
186058931./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
186149661./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
186450401./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
186481991./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
186730031./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
186730051./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
186988361./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
186521401./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
186838801./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
186537601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
186805201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
186536401./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
186849601./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
186619801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
186820201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121051./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
31591./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
39411./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
16201./30000*sint
PT
Movement time (period between SR and HEplat-ON)
55611./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
267601./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
200401./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1751./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
182intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
186990111./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_182
Information on digital trial events
Time when trial start event is internally activated.
186990111./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
186996701./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
187110971./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
187231371./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
187322181./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
187622941./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
187673141./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
187917461./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
187917511./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
188159771./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
187756501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
188000101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
187910401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
187974901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
187741501./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
188021101./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
187807501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
187987201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120861./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120401./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90811./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300761./30000*sint
DELAY
Reaction time (period between GO and SR)
50201./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
83361./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
153901./30000*sint
PT
Movement time (period between SR and HEplat-ON)
237261./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
64501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
179701./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1611./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
183intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
188161381./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
191intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_183
Information on digital trial events
Time when trial start event is internally activated.
188161381./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
188167391./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
188282151./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
188402641./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
188493111./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
188793921./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
188853711./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
189330651./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120771./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120491./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90471./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
59791./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
184intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
189332161./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_184
Information on digital trial events
Time when trial start event is internally activated.
189332161./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
189338081./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
190010371./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
189415281./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1691./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
185intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
190012061./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_185
Information on digital trial events
Time when trial start event is internally activated.
190012061./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
190018011./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
190132581./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
190253051./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
190343521./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
190644321./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
190676251./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
190905451./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
190905481./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
191141061./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
190711201./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
190986001./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
190728601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
190959001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
190726801./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
190980901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
190767001./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
190873201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120521./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120471./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90471./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300801./30000*sint
DELAY
Reaction time (period between GO and SR)
31931./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
34951./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
17401./30000*sint
PT
Movement time (period between SR and HEplat-ON)
52351./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
230401./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
106201./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2261./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
186intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
191143321./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_186
Information on digital trial events
Time when trial start event is internally activated.
191143321./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
191149781./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
191264251./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
191384991./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
191476081./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
191776891./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
191844231./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
192132941./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
192223401./30000*sintl101210-001.nev
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
192368831./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
191879701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
192169801./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
191898001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
192141301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
191916301./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
192180601./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
192017101./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
192162001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120931./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91091./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
67341./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
35471./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
18301./30000*sint
PT
Movement time (period between SR and HEplat-ON)
53771./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
243301./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
144901./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1031./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
187intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
192369861./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_187
Information on digital trial events
Time when trial start event is internally activated.
192369861./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
192375811./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
192490261./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
192611071./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
192701801./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
193002551./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
193040741./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
193282241./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
193518451./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
193081501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
193358401./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
193097101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
193326601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
193095301./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
193377601./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
193166401./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
193338901./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120401./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300751./30000*sint
DELAY
Reaction time (period between GO and SR)
38191./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
40761./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
15601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56361./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
229501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
172501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1011./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
188intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
193519461./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_188
Information on digital trial events
Time when trial start event is internally activated.
193519461./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
193525691./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
193639971./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
193760721./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
193851691./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
194152431./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
194189161./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
194419801./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
194419821./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
194656311./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
194228701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
194501101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
194253901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
194280901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
194238301./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
194516701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
194307001./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
194486701./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120511./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120751./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90971./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
36731./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
39541./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
25201./30000*sint
PT
Movement time (period between SR and HEplat-ON)
64741./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
27001./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
179701./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
189intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
194657811./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_189
Information on digital trial events
Time when trial start event is internally activated.
194657811./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
194663591./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
194778121./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
194898861./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
194989601./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
195290341./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
195344471./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
195568521./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
195568541./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
195805611./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
195376801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
195653101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
195400201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
195625801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
195385801./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
195652501./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
195439501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
195609001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120311./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90741./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
54131./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
32331./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
23401./30000*sint
PT
Movement time (period between SR and HEplat-ON)
55731./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
225601./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
169501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1531./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
190intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
195807141./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGHFstringl101210-001.nev
TrialType
Trial_190
Information on digital trial events
Time when trial start event is internally activated.
195807141./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
195813741./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
195928511./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
196049321./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
196140051./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
196440791./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
196473321./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
196702311./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
196792771./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
196937951./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
196513801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
196785601./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
196532401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
196743901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
196521901./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
196786201./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
196578901./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
196723201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121371./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120811./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
32531./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
40481./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
18601./30000*sint
PT
Movement time (period between SR and HEplat-ON)
59081./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
211501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
144301./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
191intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
196939461./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_191
Information on digital trial events
Time when trial start event is internally activated.
196939461./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
196945451./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
197060391./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
197180801./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
197274771./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
197577081./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
197637421./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
197906391./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
198143261./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
197670601./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
197953801./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
197706001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
197923801./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
197691001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
197968501./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
197793901./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
197946301./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120931./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120411./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
93971./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
302311./30000*sint
DELAY
Reaction time (period between GO and SR)
60341./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
33181./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
35401./30000*sint
PT
Movement time (period between SR and HEplat-ON)
68581./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
217801./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
152401./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1481./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
192intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
198144741./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
163intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_192
Information on digital trial events
Time when trial start event is internally activated.
198144741./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
198151601./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
198265861./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
198915881./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
198320801./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121121./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1521./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
193intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
198917401./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_193
Information on digital trial events
Time when trial start event is internally activated.
198917401./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
198925301./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
199039581./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
199160321./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
199251051./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
199551791./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
199599321./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
199819431./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
199819481./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
200056341./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
199629301./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
199892701./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
199646401./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
199838101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
199646701./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
199916701./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
199699801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
199876801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
122181./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
47531./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
29981./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
17101./30000*sint
PT
Movement time (period between SR and HEplat-ON)
47081./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
191701./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
177001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2041./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
194intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
200058381./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_194
Information on digital trial events
Time when trial start event is internally activated.
200058381./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
200064641./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
200179421./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
200300221./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
200390951./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
200691691./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
200748831./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
200975481./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
200975531./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
201215991./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
200782801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
201066001./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
200808001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
201030901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
200799001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
201078901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
200922001./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
201049501./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121041./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120801./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90731./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
57141./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
33971./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
25201./30000*sint
PT
Movement time (period between SR and HEplat-ON)
59171./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
222901./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
127501./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1361./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
195intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
201217351./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_195
Information on digital trial events
Time when trial start event is internally activated.
201217351./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
201223921./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
201338171./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
201458621./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
201549411./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
201850151./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
201877881./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
202104841./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
202104861./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
202195301./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
202344211./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
201913801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
202199401./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
201943501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
202113001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
201928201./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
202206301./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
201982801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
202171801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120821./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120451./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90791./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
27731./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
35921./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
29701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
65621./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
169501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
189001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
196intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
202345711./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_196
Information on digital trial events
Time when trial start event is internally activated.
202345711./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
202352101./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
202466351./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
202587451./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
202677861./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
202978671./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
203033671./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
203268501./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
203268541./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
203358971./30000*sintl101210-001.nev
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
203519161./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
202345801./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
203835901./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
202347601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
203528101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
203084401./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
203380501./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
203155501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
203350501./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120641./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
121101./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90411./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
55001./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-687871./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
1801./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-686071./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
1180501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
195001./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2171./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
197intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
203521331./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_197
Information on digital trial events
Time when trial start event is internally activated.
203521331./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
203527471./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
203641741./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
203762501./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
203853481./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
204154221./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
204211621./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
204453001./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
204688651./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
204246601./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
204532201./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
204264301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
204501601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
204263701./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
204546301./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
204343501./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
204489601./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120411./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120761./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90981./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300741./30000*sint
DELAY
Reaction time (period between GO and SR)
57401./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
34981./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
17701./30000*sint
PT
Movement time (period between SR and HEplat-ON)
52681./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
237301./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
146101./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1261./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
198intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
204689911./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
161intl101210-001.nev
PerformanceCode
Trial type of trial
NONEstringl101210-001.nev
TrialType
Trial_198
Information on digital trial events
Time when trial start event is internally activated.
204689911./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
204701701./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
-11./30000*sint
WS-ON
Time when CUE (first cue) is activated.
-11./30000*sint
CUE-ON
Time when CUE (first cue) is deactivated.
-11./30000*sint
CUE-OFF
Time when GO (second cue) is activated.
-11./30000*sint
GO-ON
Time when the table switch is released.
-11./30000*sint
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
-11./30000*sint
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
205422901./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
204826071./30000*sintl101210-001.nev
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
-1int
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Falseboolean
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
-11./30000*sint
OT
Time when target object is released
-11./30000*sint
OR
Onset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
-11./30000*sint
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
-11./30000*sint
DO
Time when object moved back to its baseline
-11./30000*sint
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
-11./30000*sint
HEplat-ON
Offset time plateau phase of used HE sensor signal
-11./30000*sint
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
-11./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
-11./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
-11./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
-11./30000*sint
DELAY
Reaction time (period between GO and SR)
-11./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
-11./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
-11./30000*sint
PT
Movement time (period between SR and HEplat-ON)
-11./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
-11./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
-11./30000*sint
HEplat
Inter-trial-interval (period until next trial)
3981./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
199intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
205426881./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_199
Information on digital trial events
Time when trial start event is internally activated.
205426881./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
205434101./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
205548851./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
205669331./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
205760151./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
206060871./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
206093991./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
206344631./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
206435101./30000*sintl101210-001.nev
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
206580271./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
206398501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
206416201./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
206405701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
206409001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
206140201./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
206421001./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
206265601./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
206355301./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
121971./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120481./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90821./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300721./30000*sint
DELAY
Reaction time (period between GO and SR)
33121./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
304511./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
7201./30000*sint
PT
Movement time (period between SR and HEplat-ON)
311711./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
3301./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
89701./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1501./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
200intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
206581771./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_200
Information on digital trial events
Time when trial start event is internally activated.
206581771./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
206588081./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
206702471./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
206822941./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
206914001./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
207214481./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
207246311./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
207469051./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
207469101./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
207704701./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
207280501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
207556801./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
207303301./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
207408901./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
207288301./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
207563401./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
207352801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
207489601./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120701./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120471./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91061./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300481./30000*sint
DELAY
Reaction time (period between GO and SR)
31831./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
34191./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
22801./30000*sint
PT
Movement time (period between SR and HEplat-ON)
56991./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
105601./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
136801./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2431./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
201intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
207707131./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_201
Information on digital trial events
Time when trial start event is internally activated.
207707131./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
207713661./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
207827921./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
207948341./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
208040291./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
208341101./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
208397231./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
-11./30000*sint
SR-REP
Time when reward pump is activated
208624791./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
208864631./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
208434601./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
208717801./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
208460101./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
208633201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
208453801./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
208728901./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
208486201./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
208706101./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120791./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120421./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
91951./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
56131./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
37371./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
25501./30000*sint
PT
Movement time (period between SR and HEplat-ON)
62871./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
173101./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
219901./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2251./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
202intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
208866881./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGLFstringl101210-001.nev
TrialType
Trial_202
Information on digital trial events
Time when trial start event is internally activated.
208866881./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
208872601./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
208987381./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
209107861./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
209198661./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
209499681./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
209518481./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
209741251./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
209741291./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
209977701./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
209560501./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
209822101./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
209574001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
209793601./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
209565601./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
209836801./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
209628301./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
209805001./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120501./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120481./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90801./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
301021./30000*sint
DELAY
Reaction time (period between GO and SR)
18801./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
42021./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
13501./30000*sint
PT
Movement time (period between SR and HEplat-ON)
55521./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
219601./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
176701./30000*sint
HEplat
Inter-trial-interval (period until next trial)
1511./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
203intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
209979211./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
PGHFstringl101210-001.nev
TrialType
Trial_203
Information on digital trial events
Time when trial start event is internally activated.
209979211./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
209985011./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
210099531./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
210219931./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
210310741./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
210612781./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
210647101./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
210887021./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
210887061./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
211122311./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
210687301./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
210965401./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
210718201./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
210932701./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
210695101./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
210964801./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
210779401./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
210916801./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120321./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120401./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90811./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
302041./30000*sint
DELAY
Reaction time (period between GO and SR)
34321./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
40201./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
30901./30000*sint
PT
Movement time (period between SR and HEplat-ON)
71101./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
214501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
137401./30000*sint
HEplat
Inter-trial-interval (period until next trial)
2441./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
Information on trial parameters
Consecutive trial ID (starting at 1).
204intl101210-001.nev
TrialID
Time stamp based trial ID defined as time of TS belonging to the trial.
211124751./30000*sintl101210-001.nev
TrialTimestampID
Code indicates if this was an error or a correct trial (see list of performance codes in Project/PerformanceCodes)
255intl101210-001.nev
PerformanceCode
Trial type of trial
SGLFstringl101210-001.nev
TrialType
Trial_204
Information on digital trial events
Time when trial start event is internally activated.
211124751./30000*sintl101210-001.nev
TS-ON
Time when trial start event is internally deactivated.
211130491./30000*sintl101210-001.nev
TS-OFF
Time when warning signal is activated.
211244891./30000*sintl101210-001.nev
WS-ON
Time when CUE (first cue) is activated.
211365631./30000*sintl101210-001.nev
CUE-ON
Time when CUE (first cue) is deactivated.
211456031./30000*sintl101210-001.nev
CUE-OFF
Time when GO (second cue) is activated.
211756841./30000*sintl101210-001.nev
GO-ON
Time when the table switch is released.
211793811./30000*sintl101210-001.nev
SR
Repetition of SR-ON (does not imply that the switch was released again). This event can be typically ignored.
212027271./30000*sintl101210-001.nev
SR-REP
Time when reward pump is activated
212027291./30000*sintl101210-001.nev
RW-ON
Repetition of RW-ON (does not necessarily imply that a reward was given again). This event can be typically ignored.
-11./30000*sint
RW-ON-REP
Time when reward pump is deactivated
-11./30000*sint
RW-OFF
End of trial (includes deactivation of reward pump unless RW-OFF exists)
212265181./30000*sintl101210-001.nev
STOP
Time when error flash was shown as negative feedback in response to an error trial
-11./30000*sint
ERROR-FLASH-ON
DigitalEvents
recording/task/trial/events
Information on analogue trial events
Channel ID index of force sensor used in grip force detection
1intfe_l101210-001_time_markers.mat
UsedForceSensor
States if analogue event detection of this trial was manually controlled
Truebooleanfe_l101210-001_time_markers.mat
ManuallyControlled
AnalogEvents
Information on analogue events detected with grip force signals
Time when target object is touched
211829701./30000*sintfe_l101210-001_time_markers.mat
OT
Time when target object is released
212115301./30000*sintfe_l101210-001_time_markers.mat
OR
Onset time plateau phase of used FSR sensor signal
211860001./30000*sintfe_l101210-001_time_markers.mat
FSRplat-ON
Offset time plateau phase of used FSR sensor signal
212002501./30000*sintfe_l101210-001_time_markers.mat
FSRplat-OFF
GripForceSignals
recording/task/trial/events
Information on analogue events detected with object displacement signal
Time when object first starts to move
211845001./30000*sintfe_l101210-001_time_markers.mat
DO
Time when object moved back to its baseline
212127301./30000*sintfe_l101210-001_time_markers.mat
OBB
Onset time plateau phase of used HE sensor signal; corresponds to the offline detected hold start (HS)
211957801./30000*sintfe_l101210-001_time_markers.mat
HEplat-ON
Offset time plateau phase of used HE sensor signal
212095201./30000*sintfe_l101210-001_time_markers.mat
HEplat-OFF
DisplacementSignal
recording/task/trial/events
recording/task/trial/events
Information on trial periods
Duration of start period (period between TS and WS-ON)
120141./30000*sint
STP
Duration of warning signal period (period between WS and CUE-ON)
120741./30000*sint
WSP
Duration of CUE period (period between CUE-ON and CUE-OFF)
90401./30000*sint
CUE
Duration of DELAY period (period between CUE-OFF and GO-ON)
300811./30000*sint
DELAY
Reaction time (period between GO and SR)
36971./30000*sint
RT
Reach-to-grasp time (period between SR and OT)
35891./30000*sint
RGT
Pull time (period between DO and HEplat-ON)
30301./30000*sint
PT
Movement time (period between SR and HEplat-ON)
66191./30000*sint
MT
Duration of plateau in FSR signal (period between FSRplat-ON and FSRplat-OFF)
142501./30000*sint
FSRplat
Duration of plateau in HE signal (period between HEplat-ON and HEplat-OFF)
137401./30000*sint
HEplat
Inter-trial-interval (period until next trial)
-11./30000*sint
ITI
Periods
recording/task/trial/periods
recording/task/trial
recording/task
recording
Information on preprocessing performed on the data, e.g., rejections of trial and electrodes, spike sorting.
List of identifiers of different frequency bands for which an analysis to determine trials and electrodes to be rejected were performed.
HFCstring
LFCstring
IFCstring
LFPBands
PreProcessing
Information on rejected trials and rejected electrodes based on LFPs filtered in the HFC band
High cut frequency of rejection filter
250.0Hzfloatl101210-001_rej_060Hz-250Hz-05o.hdf5
Highcut
Low cut frequency of rejection filter
60.0Hzfloatl101210-001_rej_060Hz-250Hz-05o.hdf5
Lowcut
Order of rejection filter
5intl101210-001_rej_060Hz-250Hz-05o.hdf5
Order
ID list of rejected electrodes
-1intl101210-001_rej_060Hz-250Hz-05o.hdf5
RejElectrodes
ID list of rejected trials
-1intl101210-001_rej_060Hz-250Hz-05o.hdf5
RejTrials
HFC
subject/preparation
Information on rejected trials and rejected electrodes based on LFPs filtered in the LFC band
High cut frequency of rejection filter
10.0Hzfloatl101210-001_rej_003Hz-010Hz-03o.hdf5
Highcut
Low cut frequency of rejection filter
3.0Hzfloatl101210-001_rej_003Hz-010Hz-03o.hdf5
Lowcut
Order of rejection filter
3intl101210-001_rej_003Hz-010Hz-03o.hdf5
Order
ID list of rejected electrodes
-1intl101210-001_rej_003Hz-010Hz-03o.hdf5
RejElectrodes
ID list of rejected trials
-1intl101210-001_rej_003Hz-010Hz-03o.hdf5
RejTrials
LFC
subject/preparation
Information on rejected trials and rejected electrodes based on LFPs filtered in the IFC band
High cut frequency of rejection filter
40.0Hzfloatl101210-001_rej_012Hz-040Hz-03o.hdf5
Highcut
Low cut frequency of rejection filter
12.0Hzfloatl101210-001_rej_012Hz-040Hz-03o.hdf5
Lowcut
Order of rejection filter
3intl101210-001_rej_012Hz-040Hz-03o.hdf5
Order
ID list of rejected electrodes
2intl101210-001_rej_012Hz-040Hz-03o.hdf5
4intl101210-001_rej_012Hz-040Hz-03o.hdf5
29intl101210-001_rej_012Hz-040Hz-03o.hdf5
RejElectrodes
ID list of rejected trials
139intl101210-001_rej_012Hz-040Hz-03o.hdf5
117intl101210-001_rej_012Hz-040Hz-03o.hdf5
102intl101210-001_rej_012Hz-040Hz-03o.hdf5
8intl101210-001_rej_012Hz-040Hz-03o.hdf5
45intl101210-001_rej_012Hz-040Hz-03o.hdf5
66intl101210-001_rej_012Hz-040Hz-03o.hdf5
80intl101210-001_rej_012Hz-040Hz-03o.hdf5
136intl101210-001_rej_012Hz-040Hz-03o.hdf5
140intl101210-001_rej_012Hz-040Hz-03o.hdf5
146intl101210-001_rej_012Hz-040Hz-03o.hdf5
173intl101210-001_rej_012Hz-040Hz-03o.hdf5
178intl101210-001_rej_012Hz-040Hz-03o.hdf5
200intl101210-001_rej_012Hz-040Hz-03o.hdf5
106intl101210-001_rej_012Hz-040Hz-03o.hdf5
177intl101210-001_rej_012Hz-040Hz-03o.hdf5
195intl101210-001_rej_012Hz-040Hz-03o.hdf5
RejTrials
IFC
subject/preparation
Information on spike sorting
Software used to perform offline spike sorting
Plexon Offline Spike Sorterstring
Software
Software version used to perform offline spike sorting
3.3string
SoftwareVersion
Name of the person who performed the sorting
Alexa Riehlestring
ResponsiblePerson
IDs of sorting versions available for this dataset
-02string
Sortings
OfflineSpikeSorting
Information on one particular spike sorting of the data
File containing results of offline spike sorting
l101210-001-02string
Filename
Clustering method(s) used for sorting
K-Means string
Valley-Seekingstring
Method
Level of supervision of the method (manual/semi-automatic/automatic)
semi-automaticstring
MethodType
Threshold used to remove outliers from the unit clusters
0.8float
2.0float
OutlierThreshold
Total number of offline sorted SUA units
93int
TotalNum_SUAs
Total number of offline sorted MUA units
49int
TotalNum_MUAs
Unit ID(s) reserved for noise in the offline spike sorting
0int
255int
NoiseUnitIDs
Minimum percentage of channels with a synchronously detected spike events used to reject these spike events
70int
SyncChannelLimit
Sorting-02
subject/preparation
subject/preparation
preprocessing
0.1
Lyuba Zehl