http://portal.g-node.org/odml/terminologies/v1.0/terminologies.xml
BaselineActivity-value-1
stimulus/value
Modality
voltage
SamplingRate
100kHz
StartTime
0s
Duration
1e-05s
Intensity
0V
FICurve-pulse-1
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.176471V
IntensityOffset
0V
FICurve-pulse-2
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.0349232V
IntensityOffset
0V
FICurve-pulse-3
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.442871V
IntensityOffset
0V
FICurve-pulse-4
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.25629V
IntensityOffset
0V
FICurve-pulse-5
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.691259V
IntensityOffset
0V
FICurve-pulse-6
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.481575V
IntensityOffset
0V
FICurve-pulse-7
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.932458V
IntensityOffset
0V
FICurve-pulse-8
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.716975V
IntensityOffset
0V
FICurve-pulse-9
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.230262V
IntensityOffset
0V
FICurve-pulse-10
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.00711929V
IntensityOffset
0V
FICurve-pulse-11
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.459509V
IntensityOffset
0V
FICurve-pulse-12
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.248427V
IntensityOffset
0V
FICurve-pulse-13
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.690563V
IntensityOffset
0V
FICurve-pulse-14
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.474024V
IntensityOffset
0V
FICurve-pulse-15
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.93349V
IntensityOffset
0V
FICurve-pulse-16
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.719872V
IntensityOffset
0V
FICurve-pulse-17
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.225135V
IntensityOffset
0V
FICurve-pulse-18
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.00341825V
IntensityOffset
0V
FICurve-pulse-19
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.475406V
IntensityOffset
0V
FICurve-pulse-20
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.232332V
IntensityOffset
0V
FICurve-pulse-21
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.711085V
IntensityOffset
0V
FICurve-pulse-22
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.474375V
IntensityOffset
0V
FICurve-pulse-23
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.942734V
IntensityOffset
0V
FICurve-pulse-24
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.70717V
IntensityOffset
0V
FICurve-pulse-25
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.23168V
IntensityOffset
0V
FICurve-pulse-26
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.00393756V
IntensityOffset
0V
FICurve-pulse-27
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.463534V
IntensityOffset
0V
FICurve-pulse-28
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.251211V
IntensityOffset
0V
FICurve-pulse-29
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.688322V
IntensityOffset
0V
FICurve-pulse-30
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.489655V
IntensityOffset
0V
FICurve-pulse-31
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.918563V
IntensityOffset
0V
FICurve-pulse-32
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.734385V
IntensityOffset
0V
FICurve-pulse-33
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.208011V
IntensityOffset
0V
FICurve-pulse-34
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.0248642V
IntensityOffset
0V
FICurve-pulse-35
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.440717V
IntensityOffset
0V
FICurve-pulse-36
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.264077V
IntensityOffset
0V
FICurve-pulse-37
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.674706V
IntensityOffset
0V
FICurve-pulse-38
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.504056V
IntensityOffset
0V
FICurve-pulse-39
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.906026V
IntensityOffset
0V
FICurve-pulse-40
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
0.734948V
IntensityOffset
0V
FICurve-pulse-41
stimulus
Modality
voltage
SamplingRate
1kHz
TestStimulus
stimulus/pulse
StartTime
0s
Duration
0.4s
Intensity
-0.210805V
IntensityOffset
0V
SAM-sine_wave-1
stimulus/sine_wave
Modality
voltage
SamplingRate
99.5025kHz
StartTime
0s
Duration
1s
Amplitude
1V
Frequency
150.972Hz
Phase
0
SAM-sine_wave-2
stimulus/sine_wave
Modality
voltage
SamplingRate
99.5025kHz
StartTime
0s
Duration
1s
Amplitude
1V
Frequency
150.989Hz
Phase
0
SAM-sine_wave-3
stimulus/sine_wave
Modality
voltage
SamplingRate
99.5025kHz
StartTime
0s
Duration
1s
Amplitude
1V
Frequency
250.728Hz
Phase
0
SAM-sine_wave-4
stimulus/sine_wave
Modality
voltage
SamplingRate
99.0099kHz
StartTime
0s
Duration
1s
Amplitude
1V
Frequency
250.552Hz
Phase
0
SAM-sine_wave-5
stimulus/sine_wave
Modality
voltage
SamplingRate
99.5025kHz
StartTime
0s
Duration
0.998793s
Amplitude
1V
Frequency
350.423Hz
Phase
0
SAM-sine_wave-6
stimulus/sine_wave
Modality
voltage
SamplingRate
99.5025kHz
StartTime
0s
Duration
0.999178s
Amplitude
1V
Frequency
350.288Hz
Phase
0
SAM-sine_wave-7
stimulus/sine_wave
Modality
voltage
SamplingRate
99.0099kHz
StartTime
0s
Duration
0.999727s
Amplitude
1V
Frequency
450.123Hz
Phase
0
SAM-sine_wave-8
stimulus/sine_wave
Modality
voltage
SamplingRate
99.0076kHz
StartTime
0s
Duration
0.999923s
Amplitude
1V
Frequency
450.035Hz
Phase
0
SAM-sine_wave-9
stimulus/sine_wave
Modality
voltage
SamplingRate
99.0099kHz
StartTime
0s
Duration
1.00057s
Amplitude
1V
Frequency
549.686Hz
Phase
0
SAM-sine_wave-10
stimulus/sine_wave
Modality
voltage
SamplingRate
99.0099kHz
StartTime
0s
Duration
1.00087s
Amplitude
1V
Frequency
549.525Hz
Phase
0
SAM-sine_wave-11
stimulus/sine_wave
Modality
voltage
SamplingRate
99.0099kHz
StartTime
0s
Duration
0.999244s
Amplitude
1V
Frequency
749.567Hz
Phase
0
SAM-sine_wave-12
stimulus/sine_wave
Modality
voltage
SamplingRate
99.0099kHz
StartTime
0s
Duration
0.99882s
Amplitude
1V
Frequency
749.885Hz
Phase
0
SAM-sine_wave-13
stimulus/sine_wave
Modality
voltage
SamplingRate
98.5222kHz
StartTime
0s
Duration
0.997714s
Amplitude
1V
Frequency
849.943Hz
Phase
0
SAM-sine_wave-14
stimulus/sine_wave
Modality
voltage
SamplingRate
98.5222kHz
StartTime
0s
Duration
0.998017s
Amplitude
1V
Frequency
849.685Hz
Phase
0
SAM-sine_wave-15
stimulus/sine_wave
Modality
voltage
SamplingRate
99.0099kHz
StartTime
0s
Duration
1.00139s
Amplitude
1V
Frequency
949.678Hz
Phase
0