Brain Vision Data Exchange Header File Version 1.0 ; Data created by the Vision Recorder [Common Infos] Codepage=UTF-8 DataFile=239_oddball.eeg MarkerFile=239_oddball.vmrk DataFormat=BINARY ; Data orientation: MULTIPLEXED=ch1,pt1, ch2,pt1 ... DataOrientation=MULTIPLEXED NumberOfChannels=32 ; Sampling interval in microseconds SamplingInterval=2000 [Binary Infos] BinaryFormat=IEEE_FLOAT_32 [Channel Infos] ; Each entry: Ch=,, ; ,, Future extensions.. ; Fields are delimited by commas, some fields might be omitted (empty). ; Commas in channel names are coded as "\1". Ch1=Fp1,,0.0406901,µV Ch2=Fz,,0.0406901,µV Ch3=F3,,0.0406901,µV Ch4=F7,,0.0406901,µV Ch5=FT9,,0.0406901,µV Ch6=FC5,,0.0406901,µV Ch7=FC1,,0.0406901,µV Ch8=C3,,0.0406901,µV Ch9=T7,,0.0406901,µV Ch10=TP9,,0.0406901,µV Ch11=CP5,,0.0406901,µV Ch12=CP1,,0.0406901,µV Ch13=Pz,,0.0406901,µV Ch14=P3,,0.0406901,µV Ch15=P7,,0.0406901,µV Ch16=O1,,0.0406901,µV Ch17=Oz,,0.0406901,µV Ch18=O2,,0.0406901,µV Ch19=P4,,0.0406901,µV Ch20=P8,,0.0406901,µV Ch21=TP10,,0.0406901,µV Ch22=CP6,,0.0406901,µV Ch23=CP2,,0.0406901,µV Ch24=Cz,,0.0406901,µV Ch25=C4,,0.0406901,µV Ch26=T8,,0.0406901,µV Ch27=FT10,,0.0406901,µV Ch28=FC6,,0.0406901,µV Ch29=FC2,,0.0406901,µV Ch30=F4,,0.0406901,µV Ch31=F8,,0.0406901,µV Ch32=Fp2,,0.0406901,µV [Coordinates] ; Electrode Position File: C:\Users\admin-local\Desktop\actiCAP for LiveAmp 32 Channel\CLA-32.bvef Ch1=1,-90,-72 Ch2=1,45,90 Ch3=1,-60,-51 Ch4=1,-90,-36 Ch5=1,-113,-18 Ch6=1,-69,-22 Ch7=1,-31,-46 Ch8=1,-45,0 Ch9=1,-90,0 Ch10=1,-113,18 Ch11=1,-69,21 Ch12=1,-31,46 Ch13=1,45,-90 Ch14=1,-60,51 Ch15=1,-90,36 Ch16=1,-90,72 Ch17=1,90,-90 Ch18=1,90,-72 Ch19=1,60,-51 Ch20=1,90,-36 Ch21=1,113,-18 Ch22=1,69,-21 Ch23=1,31,-46 Ch24=1,0,0 Ch25=1,45,0 Ch26=1,90,0 Ch27=1,113,18 Ch28=1,69,21 Ch29=1,31,46 Ch30=1,60,51 Ch31=1,90,36 Ch32=1,90,72 [Comment] BrainVision Recorder Professional - V. 1.21.0303 A m p l i f i e r S e t u p ============================ Number of channels: 32 Sampling Rate [Hz]: 500 Sampling Interval [µS]: 2000 Channels -------- # Name Phys. Chn. Resolution / Unit Low Cutoff [s] High Cutoff [Hz] Notch [Hz] Gradient Offset 1 Fp1 1 0.0406901 µV DC 131 Off 2 Fz 2 0.0406901 µV DC 131 Off 3 F3 3 0.0406901 µV DC 131 Off 4 F7 4 0.0406901 µV DC 131 Off 5 FT9 5 0.0406901 µV DC 131 Off 6 FC5 6 0.0406901 µV DC 131 Off 7 FC1 7 0.0406901 µV DC 131 Off 8 C3 8 0.0406901 µV DC 131 Off 9 T7 9 0.0406901 µV DC 131 Off 10 TP9 10 0.0406901 µV DC 131 Off 11 CP5 11 0.0406901 µV DC 131 Off 12 CP1 12 0.0406901 µV DC 131 Off 13 Pz 13 0.0406901 µV DC 131 Off 14 P3 14 0.0406901 µV DC 131 Off 15 P7 15 0.0406901 µV DC 131 Off 16 O1 16 0.0406901 µV DC 131 Off 17 Oz 17 0.0406901 µV DC 131 Off 18 O2 18 0.0406901 µV DC 131 Off 19 P4 19 0.0406901 µV DC 131 Off 20 P8 20 0.0406901 µV DC 131 Off 21 TP10 21 0.0406901 µV DC 131 Off 22 CP6 22 0.0406901 µV DC 131 Off 23 CP2 23 0.0406901 µV DC 131 Off 24 Cz 24 0.0406901 µV DC 131 Off 25 C4 25 0.0406901 µV DC 131 Off 26 T8 26 0.0406901 µV DC 131 Off 27 FT10 27 0.0406901 µV DC 131 Off 28 FC6 28 0.0406901 µV DC 131 Off 29 FC2 29 0.0406901 µV DC 131 Off 30 F4 30 0.0406901 µV DC 131 Off 31 F8 31 0.0406901 µV DC 131 Off 32 Fp2 32 0.0406901 µV DC 131 Off LiveAmp SN: LA-056309-0523 LiveAmp hardware revision: 5 Firmware version: 4.71 Sensor and trigger extension SN: STE-056305-0185 Sensor and trigger extension hardware revision: 1 Sensor and trigger extension firmware version: 1.14 Library version: 9.17.10.12 Use Active/Dry Electrodes: Yes S o f t w a r e F i l t e r s ============================== Disabled Data/Gnd/Ref Electrodes Selected Impedance Measurement Range: 25 - 60 kOhm Impedance [kOhm] at 08:55:50 : Fp1: 20 Fz: 14 F3: 15 F7: 10 FT9: 2 FC5: 12 FC1: 19 C3: 10 T7: 15 TP9: 13 CP5: 9 CP1: 7 Pz: 9 P3: 7 P7: 16 O1: 17 Oz: 18 O2: 14 P4: 4 P8: 11 TP10: 2 CP6: 14 CP2: 5 Cz: 20 C4: 8 T8: 12 FT10: 5 FC6: 20 FC2: 1 F4: 4 F8: 13 Fp2: 13 Gnd: 5 Ref: 10