BrainVision Recorder 1.2
EEG cap captures the signal of neuronal activity in the brain from the head surface using electrode application technique.
string
Type
new
Recording and auditory presentation computer
Experiment
new
string
Inventory number
Electro-Cap International, Inc. Eaton, Ohio 45320 USA
string
New property name5
Nuprep gel is applied to electrode site on scalp with cotton swab. EEG electrode paste and reference or ground electrode is applied over Nuprep gel.
Power supply
new
Inventory number
string
Description
string
Serial number
string
20
Signal tester
new
Eye Blink Detection Electrode
new
A Faraday cage or Faraday shield is an enclosure formed by conducting material or by a mesh of such material. Such an enclosure blocks external static and non-static electric fields.
new
EEG devices
Owner
string
190258
Experimenters
new
Soundproof cabin
new
male
Gender
string
string
Reference
PP0711288
New property value
Description
string
string
Serial number
scenario-title
string
Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
BRAIN AMP DC
new
Degreasing Gel
Serial number
string
Brain BUA 64
Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
string
Faraday cage
new
Ground Electrode
Description
string
Reference
string
BUA64-0711330
ELECTRODE INPUT BOX 64 CHANNEL
string
Sampling-rate
string
Owner
http://www.brainproducts.com/productdetails.php?id=16&tab=3
21050
string
Manufacturer
string
Inventory number
string
Title
string
Title
Owner
string
"POWER PACK is used as a power system for standard EEG/ERP recordings as it fully eliminates problems with 50/60 Hertz mains noise."
Owner
string
Digitization
new
Stimulation device
Inventory number
string
string
Title
string
Type
Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
144_eegbase_conv.xml
2015-07-16
1
new
Power pack
Brain Products
Manufacturer
string
Type
string
Electro Gel
new
Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
Subject
new
new
USB 2.0 adapter
string
Type
end-time
string
Electro-Cap International, Inc. Eaton, Ohio 45320 USA
Corsair
Reference Electrode
new
Title
string
Description
string
Reference
string
string
Description
string
Owner
Description
string
string
Manufacturer
Owner
string
string
Title
new
Electrode
Title
string
string
Manufacturer
Manufacturer
string
new
EEG cap
Amplifier
new
Description
string
Stimulation device is based on ARM Cortex microcontroller unit and it can present visual stimuli, auditory stimuli and combination of these. Outputs: 1) Visual stimuli - simple LED diodes, LED panels, patterns presented on small LCD displays or any images in defined format presented on normal LCD monitor, 2) Auditory stimuli - simple tones of various frequencies, any sound saved in wav file, 3) Synchronization output - for synchronizing events with measuring device. Can be also used as GPIO Inputs: 4 response buttons - can be assigned to any visual or auditory stimulus.
Description
string
new
Stimulation device for cognitive research
Conductive Paste
new
Description
string
string
Description
Manufacturer
string
23
Type
string
research-group
string
E21-9S DISK ELECTRODE
Hardware device which provides an interface between an amplifier (optic fiber) and computer (USB2).
Closable cabin formed by conducting material for one person (approx 2x2x1,5m) which muffle external noise. Cabin blocks external static and non-static electric fields by channeling electricity through conducting material and provides constant voltage on all sides of the cabin. Subject inside is screened out from events in the lab during the experiment. The cabin contains ventilation, light and window.
string
Owner
AMP0711758DC
EIB06031122
Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
190257
Manufacturer
string
string
Experimenter #1
string
Reference
string
Inventory number
string
Description
Martin Fornbaum
input 1x100-240V 50/60Hz (100Watts-180mA, output 5,6 DC)
Signal tester is a device for verify the functionality of the amplifier. Device generates rectangular waveform.
new
Hardware
192421
Title
string
Electro-Cap International, Inc. Eaton, Ohio 45320 USA
Type
string
Type
string
Owner
string
string
Description
08.04.2010, 10:45:00
string
Description
Ten20 is a conductive and adhesive paste specifically formulated for use with reusable (non-disposable) electrodes. Primarily used for EEG electrodes. (http://www.biopac.com/ten20-conductivegel)
string
Title
PS607110246wr
http://www.electro-cap.com/index.cfm/supplies/
Standard 9mm cup
ELECTRO-GEL NET:16
BRUVAR
191683
ELECTRO-Cap International, Inc. 1011 W. Lexington Road Eaton, Ohio 45320 U.S.A.
http://www.electro-cap.com/index.cfm/supplies/
string
Title
Temperature
string
This computer used processor Intel Core i7 CPU 3,2GHz 3,19GHz. It has 12 GB RAM. Device is used for recording EEG/ERP.
Standard 9mm cup
Description
string
Manufacturer
string
Electro-Cap International, Inc. Eaton, Ohio 45320 USA
new
Software
E5-9S EAR ELECTRODE
08.04.2010, 10:58:00
1000 Hz
Manufacturer
string
Serial number
string
string
start-time
Serial number
string
string
Description
An electrode is an electrical conductor used to make contact with a nonmetallic part of a circuit (e.g., the human scalp) and is used to measure electrical activity. http://purl.bioontology.org/NEMO/ontology/NEMO.owl#NEMO_0000501
string
Description
new
Electrode input box
Nuprep
string
Inventory number
new
Accessories
Reference
string
Input box device which provides an interface between an EEG cap and amplifier.
string
Description
http://www.webopedia.com/TERM/P/power_supply.html
A pair of pure tin cup electrodes with a 48" (122 cm) lead wire and a female socket. A spring-clip back, covered with plastic for patient comfort, is used to hold the electrode in place. Device is used as a ground electrode.
Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
Standard 9mm cup
A pure tin cup electrode with a 48" (122 cm) lead wire and a female socket. Device is used as a reference electrode.
Large, 58 - 62 cm (dark blue)
192422
A pure tin cup electrode with a 48" (122 cm) lead wire and a female socket. Device is used as a reference electrode.
Weaver and Company 565 Nucla Way Unit B Aurora, CO 80011 Toll Free 800-525-2130 Fax 303-367-5118
The BrainAmp DC is used for recording EEG signal and the full range of evoked potentials.
E21-9S DISK ELECTRODE
Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
Steady State Visually Evoked Potentials (SSVEP)
Type
string
Weaver and Company 565 Nucla Way Unit B Aurora, CO 80011 Toll Free 800-525-2130 Fax 303-367-5118
This electro-gel is an off white color, water-miscible conductive gel. Electro-gel is a mixture of the following components: Water, Sodium Chloride, Aragum, Glycerin, Pottasium Bitartrate, Methylparaben and Propylparaben. Electro gel is applied by inserting the gel into the EEG cap electrodes by using a syringe and blunted needle. Electro gel is used for setting low electrode impedance and limitations of electrode artifacts.
Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
Department of Computer Science and Engineering, University of West Bohemia, Pilsen, Czech Republic
Ten 20 CONDUCTIVE EEG Paste
Reference
string
The component that supplies power to a amplifier.
http://www.electro-cap.com/index.cfm/supplies/
Brain Products
(http://www.brainproducts.com/productdetails.php?id=2&tab=1
EEG/ERP recording software