sub-80780_ses-02_flip-1_mt-1_part-phase_QMT.json 2.3 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384
  1. {
  2. "Modality": "MR",
  3. "MagneticFieldStrength": 3,
  4. "ImagingFrequency": 123.201,
  5. "Manufacturer": "Siemens",
  6. "ManufacturersModelName": "ConnectomA",
  7. "InstitutionName": "CUBRIC-3TM",
  8. "InstitutionalDepartmentName": "MRI_3TM",
  9. "InstitutionAddress": "Maindy Road StreetNo,Cardiff,Wales,GB,CF24 4HQ",
  10. "DeviceSerialNumber": "19950",
  11. "StationName": "connectom",
  12. "BodyPartExamined": "BRAIN",
  13. "PatientPosition": "HFS",
  14. "ProcedureStepDescription": "3TMproj^314_WAND",
  15. "SoftwareVersions": "syngo MR D11",
  16. "MRAcquisitionType": "3D",
  17. "SeriesDescription": "qMT_TFL4_332deg_56360Hz",
  18. "ProtocolName": "qMT_TFL4_332deg_56360Hz",
  19. "ScanningSequence": "GR",
  20. "SequenceVariant": "SK\\MTC\\SP",
  21. "ScanOptions": "PFP\\MT",
  22. "SequenceName": "tfl3d1_4ns",
  23. "ImageType": [
  24. "ORIGINAL",
  25. "PRIMARY",
  26. "P",
  27. "DIS3D",
  28. "DIS2D",
  29. "PHASE"
  30. ],
  31. "SeriesNumber": 30,
  32. "AcquisitionTime": "16:05:42.140000",
  33. "AcquisitionNumber": 1,
  34. "SliceThickness": 1.72,
  35. "SAR": 0.0971771,
  36. "EchoTime": 0.0021,
  37. "RepetitionTime": 0.055,
  38. "SpoilingState": true,
  39. "FlipAngle": "332",
  40. "PartialFourier": 0.875,
  41. "BaseResolution": 128,
  42. "ShimSetting": [
  43. 253,
  44. -1159,
  45. -997,
  46. 43,
  47. -252,
  48. 162,
  49. 427,
  50. 96
  51. ],
  52. "TxRefAmp": 336.842,
  53. "PhaseResolution": 1,
  54. "ReceiveCoilName": "Head_32",
  55. "ReceiveCoilActiveElements": "HEA;HEP",
  56. "PulseSequenceDetails": "%CustomerSeq%\\tfl_qMT_v09",
  57. "RefLinesPE": 24,
  58. "CoilCombinationMethod": "Adaptive Combine",
  59. "MTState": true,
  60. "ConsistencyInfo": "N4_VD11D_LATEST_20110129",
  61. "MatrixCoilMode": "GRAPPA",
  62. "PercentPhaseFOV": 100,
  63. "PercentSampling": 100,
  64. "PhaseEncodingSteps": 112,
  65. "AcquisitionMatrixPE": 128,
  66. "ReconMatrixPE": 128,
  67. "ParallelReductionFactorInPlane": 3,
  68. "PixelBandwidth": 330,
  69. "DwellTime": 1.19e-05,
  70. "ImageOrientationPatientDICOM": [
  71. 0,
  72. 1,
  73. 0,
  74. 0,
  75. 0,
  76. -1
  77. ],
  78. "ImageOrientationText": "Sag",
  79. "InPlanePhaseEncodingDirectionDICOM": "ROW",
  80. "ConversionSoftware": "dcm2niix",
  81. "ConversionSoftwareVersion": "v1.0.20211006",
  82. "Dcm2bidsVersion": "2.1.6",
  83. "MTOffsetFrequency": "56360"
  84. }