sub-49618_ses-07_part-phase_T2starw.json 2.2 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384
  1. {
  2. "Modality": "MR",
  3. "MagneticFieldStrength": 3,
  4. "ImagingFrequency": 123.255,
  5. "Manufacturer": "Siemens",
  6. "ManufacturersModelName": "Prisma",
  7. "InstitutionName": "CUBRIC_3T_West",
  8. "InstitutionalDepartmentName": "Department",
  9. "InstitutionAddress": "Maindy Road *,CARDIFF-Note:body18 in Connectome,Wales,GB,CF24 4HQ",
  10. "DeviceSerialNumber": "66073",
  11. "StationName": "AWP66073",
  12. "BodyPartExamined": "BRAIN",
  13. "PatientPosition": "HFS",
  14. "ProcedureStepDescription": "3TWproj^314_WAND",
  15. "SoftwareVersions": "syngo MR E11",
  16. "MRAcquisitionType": "3D",
  17. "SeriesDescription": "gre_qsm",
  18. "ProtocolName": "gre_qsm",
  19. "ScanningSequence": "GR",
  20. "SequenceVariant": "SP",
  21. "SequenceName": "*fl3d1r",
  22. "ImageType": [
  23. "ORIGINAL",
  24. "PRIMARY",
  25. "P",
  26. "ND",
  27. "PHASE"
  28. ],
  29. "SeriesNumber": 17,
  30. "AcquisitionTime": "10:01:49.267500",
  31. "AcquisitionNumber": 1,
  32. "FrameTimesStart": [
  33. 0
  34. ],
  35. "SliceThickness": 1,
  36. "SAR": 0.0158447,
  37. "EchoTime": 0.014,
  38. "RepetitionTime": 0.02,
  39. "FlipAngle": 15,
  40. "EchoTime1": 0.014,
  41. "EchoTime2": 0.015,
  42. "PartialFourier": 1,
  43. "BaseResolution": 288,
  44. "ShimSetting": [
  45. 9775,
  46. 64,
  47. -2630,
  48. 299,
  49. -47,
  50. 84,
  51. 50,
  52. 71
  53. ],
  54. "TxRefAmp": 231.258,
  55. "PhaseResolution": 1,
  56. "ReceiveCoilName": "Head_32",
  57. "ReceiveCoilActiveElements": "HEA;HEP",
  58. "PulseSequenceDetails": "%SiemensSeq%\\gre",
  59. "RefLinesPE": 24,
  60. "CoilCombinationMethod": "Adaptive Combine",
  61. "ConsistencyInfo": "N4_VE11C_LATEST_20160120",
  62. "MatrixCoilMode": "GRAPPA",
  63. "PercentPhaseFOV": 100,
  64. "PercentSampling": 100,
  65. "PhaseEncodingSteps": 287,
  66. "AcquisitionMatrixPE": 288,
  67. "ReconMatrixPE": 288,
  68. "ParallelReductionFactorInPlane": 2,
  69. "PixelBandwidth": 220,
  70. "DwellTime": 7.9e-06,
  71. "ImageOrientationPatientDICOM": [
  72. 1,
  73. 0,
  74. 0,
  75. 0,
  76. 1,
  77. 0
  78. ],
  79. "ImageOrientationText": "Tra",
  80. "InPlanePhaseEncodingDirectionDICOM": "COL",
  81. "ConversionSoftware": "dcm2niix",
  82. "ConversionSoftwareVersion": "v1.0.20211006",
  83. "Dcm2bidsVersion": "2.1.6"
  84. }